Page 11
1 ‹ Overview
7500 Series User Manual
Shipment Your 7500 Series shipment contains the following items:
‹
The requested transmitter and/or receiver units
Product code
Description
7501D
Ethernet decoder
7501E
Ethernet encoder (one input)
7502M
Ethernet encoder (two inputs)
7504M
Ethernet encoder (four inputs)
ProductCode-A
Transmitter or receiver with bidirectional audio
‹
12V DC external power supply (for North America only)
‹
A BNC cable assembly, for the 7504M only (7504M-miniDIN-3BNC)
‹
The DVTel SecureLink CD containing the documentation and release notes for the unit as well as the Device Configurator application
The shipment may also contain the following option:
‹
3, 6 or 10-unit rack mount panels.
Unit Casing Description The 7500 Series electronics are enclosed in a non-weatherproof extruded aluminium casing that is not meant for outdoor use. The front and back panels vary depending on the unit in the series.
7501E and 7502M The front panel consists of an RJ-45 jack, a status LED, a reset button, and a female DB-9 connector for RS-232 use.
RS-232 serial port connector
Status LED Reset button RJ-45 Ethernet connector
The back panel consists of a 12-pin terminal strip (for 12V DC power, alarm, and RS-422/485), one or two female BNC connectors to be used as video input or output, and optional audio connectors. RS-422/485 serial Audio connectors port connectors (optional)
Tx+
Tx-
Video Rx+
In 1
RS422/485 Gnd
In 3
Rly
In 2
In
Out Rly
Vin
Rtn
Pwr
Rx-
12V DC connectors
OUT
IN
Audio
Alarm input
Video connector 1 Video connector 2 for 7502M
3
Page 12
1 ‹ Overview
7500 Series User Manual
7504E The front panel consists of optional audio connectors, a status LED (described on page 15), a female BNC connector to be used as video input, and an auxiliary connector for the S1500e-T4.
Auxiliary video connector Video connector Status LED Audio connectors (optional)
Note The six-pin connector of the auxiliary video input is not an S-video connector.
The back panel consists of an RJ-45 jack, a status LED, a female DB-9 connector for RS-232 use, and a 10-pin terminal strip. This connector is broken down into three sections for RS-422/485, alarm, and power (12V DC). 12V DC connectors
Status LED
Alarm input
Status
RS-422/485 serial port connectors RS-232 serial port connector RJ-45 Ethernet connector
4
Vin
Pwr Rtn
Rly
Gnd
In
Rx-
Rx+
Tx+
Tx-
LAN 10/100
Rly
Out
RS422/485
Page 13
Network Planning
2
To allow optimal configuration, you must properly plan your network, especially its layout and IP address assignments. For more information on networking, refer to network equipment providers such as 3COM and Cisco.
5
Page 14
2 ‹ Network Planning
7500 Series User Manual
IP Address Assignment Wired networks can come in various shapes and sizes: from a printer plugged directly into a PC to the Internet. What is known as a local area network (LAN) consists of a group of devices (PCs, printers, access points) that share a common communications line. A wide area network (WAN) usually contains leased lines from a public carrier that permit a span of large distances (up to many hundreds of miles). The 7500 Series works best over LANs and WANs where data rates can be controlled and guaranteed. To allow communication between every device on a network without confusion, a standard protocol has been developed to permit seamless flow of information back and forth between all devices. Known as 802.3, this protocol requires devices to send all information in units of data called packets. To determine the destination device, packets are given destination addresses. The numerical addresses use the Internet Protocol (IP) and are therefore known as IP addresses. They are broken up into four fields, seperated by dots, each with a value between 1 and 254. Therefore, your address should range between 1.1.1.1 and 254.254.254.254. When installing your 7500 Series, you will have to give it a unique IP address. If you are using your own, closed network (no other devices will be on this network and it is not connected to any other LAN, WAN, or the Internet), it is strongly recommended that you use the address range 192.168.135.1 to 192.168.135.254. If you are installing the 7500 Series on an existing LAN or WAN, you should get the range of addresses for the 7500 Series from the network administrator. Some networks have a server that allocates the IP addresses. This is known as dynamic host configuration protocol, or DHCP. The 7500 Series supports this feature. If DHCP is enabled on your unit, the server will automatically allocate an IP address to the unit, making it unnecessary for you to do so. For more information about DHCP support for the 7500 Series, see Appendix C, page 29.
Network Layout It is critical to ensure that no IP link of more than 300 feet (100 meters) be present in a network, unless otherwise stated by connection equipment such as 100Base-T to SC converters which can offer a 1.24-mile (2-km) range. The 7500 Series supports a streaming method called multicast, which permits more than one receiver unit to view a video stream at any one time. Here is a typical connection of a point-to-multipoint application. R ecei v er Mon i t or 1
T r an s m i t t er Sw i t ch
R ecei v er
Vi deo sou r ce
Mon i t or 2
6
Page 15
3
Configuring and Installing Units
This chapter presents the basic installation and configuration procedures for the 7500 Series encoders and decoders. To prepare your unit for operation, you will have to perform a series of steps:
‹
Basic configuration, mainly for communication and connection
‹
Physical installation in the unit’s final location
‹
Alarm and audio configuration (if applicable)
‹
Connection to the serial ports (if applicable)
The chapter also contains information about the factory reset procedure and status LED indications.
7
Page 16
3 ‹ Configuring and Installing Units
7500 Series User Manual
Configuring the Unit The following configuration steps are required:
‹
Setting a series of parameters, including the IP address
‹
In an analog extension context, creating a point-to-point connection
Setting Unit Parameters The first step in installing a 7500 Series unit is to change ita IP address to ensure compatibility with any existing LAN or WAN. The default IP addresses of all 7500 Series units are based on the APIPA service and will be in the range 169.254.X.Y, where X and Y are based on the MAC address of the individual unit. To work properly, units on the same network must have unique IP addresses. For more information regarding networking and appropriate IP addresses, see Chapter 2, page 5, or contact your network administrator. The unit will not prevent you from entering a duplicate address. Its status LED, however, will flash red; then the unit will reboot with an APIPA address. If the unit is a receiver, the “Duplicate IP Detected” message will also be displayed in the on-screen display (for more information on this display, see Chapter 5, page 23). The IP addresses of a unit can be set by two methods:
‹
Connecting your unit to the same LAN as your PC and using Device Configurator (described next)
‹
Using the command line interface (see page 20)
Next, you have to set serial port parameters. The configuration procedure is the same for all units of the 7500 Series.
To set the parameters:
1 2
In a lab, unpack the unit and set it on a table.
3 4
Power up the unit using 12V DC.
5
From the General tab, click Program Options.
6 7
Ensure that the VSIP Port value is 5510 (the default).
Plug the 7500 Series IP connector directly to a computer using a crossover IP cable or to your LAN using a straight-through IP cable. Start the Device Configurator software included on the DVTel SecureLink CD shipped with your equipment.
Checkmark the Detect All Units on LAN box, then click OK.
8
Page 17
3 ‹ Configuring and Installing Units
8
7500 Series User Manual
Choose the Units tab, then click Discover.
A unit of type “Unknown” with a 169.254.X.Y IP address appears in the list; it corresponds to your new unit. Other units, already configured and connected to the network, may also appear.
9
Select the unit to be configured, then click Configure. In the Reconfigure unit? confirmation window, click Yes.
10 To use DHCP (dynamic host configuration protocol), checkmark Use DHCP. Otherwise, enter the IP address, subnet mask, and gateway of the unit, as provided by your network administrator. For more details on DHCP, see page 29.
11 Click OK. 12 Using the CLI (described in Chapter 4, page 16), configure the serial port parameters to match those of the dome/PTZ equipment (skip this step if you will be using your encoder/decoder with NVRS).
The 7500 Series initial configuration is now complete. You can now connect the unit to the IP network. You can perform further configuration with either the Device Configurator or NVRS Config Tool.
Creating a Point-to-Point Connection In a point-to-point analog extension context (as opposed to using the NVRS software), you have to create connections between the transmitter and receiver units, to allow transfer of video, audio, I/O, and serial port data. Both units must reside on the same IP network. For more information, refer to the “Managing Connections” chapter in the Device Configurator User Manual.
To create a point-to-point connection:
1 2
Start Device Configurator. Choose the Units tab, then click Discover. All encoder/decoder units on the network should appear in the Units list. If the unit you would like to configure does not appear, check that its VSIP port is the same as that of the computer you are using.
9
Page 18
3 ‹ Configuring and Installing Units
3
7500 Series User Manual
Choose the Connections tab and click Add. The Connection Creator window appears.
4 5 6 7 8
Select a transmitter in the left column and a receiver in the right one. To disable I/O data transmission (for example, alarms), clear Forward I/O. To disable serial port data transmission (like PTZ commands), clear Forward Serial Port Data. To enable audio, check Enable Audio, then select the audio mode. Click Connect. If Forward Serial Port Data is checked on and one of the two units involved has only one serial port, the Serial Port Connection window will appear. Otherwise, go to step 10.
9 Select the serial port from which data should be forwarded, then click OK. 10 In the information window confirming the connection was successfully created, click OK.
Installing the Unit Once your unit is successfully configured, it is ready to be installed in its final location. The number of video inputs you can connect to an encoder depends on the unit’s type. Only one video output is connected to each decoder. Depending on the context, you may, therefore, need more than one receiver for each transmitter.
‹
Point-to-point analog extension - One decoder per video input.
‹
NVRS - Decoders are optional, since all output can be viewed on a computer screen using the Monitor application.
The 7501E, 7501D and 7502M Video Servers The 7501E and 7501D each have a single video connector; the 7502M has two.
To install a unit:
1 2
Power up the unit with 12V DC.
3
If applicable, connect the RS-422/485 serial port of the unit to the appropriate dome/PTZ/control panel interface (for instructions, see page 12).
4
Plug a network cable to the video server’s RJ-45 Ethernet connector.
Connect the encoder/decoder, via its video in or video out socket, to either a camera/dome or an analog monitor. In the case of the 7502M, you can connect to two devices.
If the unit is an -XT model, make it stand vertically to allow for quicker, more effective cooling.
10
Page 19
3 ‹ Configuring and Installing Units
7500 Series User Manual
The 7504M Video Server The 7504M encoder has four video inputs.
To install a 7504M unit:
1 2
Plug the video cable of the first camera or dome to the main video connector. Plug the additional three video inputs to the BNC connectors available on the 7500-miniDIN-3BNC cable; then plug this cable to the 7504M auxiliary connector. On the auxiliary connector assembly cable, a label identifies each additional video input: video 2, video 3, and video 4. These labels match the video inputs in Device Configurator (refer to its user manual). v i deo 2 6-pi n au x i li ar y con n ect or v i deo 3 v i deo 4
B NC
B NC
B NC
3 4
Power up or reboot the unit.
5
Plug the network cable to the RJ-45 Ethernet connector.
If required, connect the RS-422/485 serial port of the unit to the appropriate dome/PTZ/control panel interface (for instructions, see page 12).
11
Page 20
3 ‹ Configuring and Installing Units
7500 Series User Manual
Configuring Alarms The alarm features on the terminal strip are bidirectional. On the 7504M, one alarm input and one alarm output are available. On the other units, there are three alarm inputs and one alarm output. You can perform alarm configuration using the Device Configurator (Connections tab). If you have NVRS, use the Config Tool instead.
Tx-
Tx+
Rx+
In 1
Rx-
RS422/485 Gnd
In 2
In In 3
Rly
Rly
Out
Vin
Pwr Rtn
Tx+
Tx-
Rx+
In 1
In1 Gnd
Rx-
RS422/485 Gnd
In 2
In In 3
Rly
Rly
Out
Vin
Pwr Rtn
The event sensor needs to be plugged to a pin in the In section of the RS422/485 connector, whereas the alarm system should be connected to the Out section. For example, on an 7501E encoder:
In2 Gnd Rly Rly Event sensor
Event sensor
Voltage source Load
Understanding the Serial Ports The 7500 Series units contain connectors for two serial ports: RS-232 and RS-422/485.
RS-232 A cable should be connected to the DB-9 connector the following way:
Pin number
Signal name
2
RxD
3
TxD
5
Signal GND
7
RTS
8
CTS
RS-422/485 To use the RS-422/485 functionality, you have to connect the twisted pair cables to the terminal strip. The terminal strip permits access to the Tx+, Tx-, Rx+, Rx-, and Gnd connections. To properly connect an RS-422/485 serial connection using four wires, use the following correspondence table:
Matrix/dome connector Tx+
7500 Series connector Tx+
Tx-
Tx-
Rx+
Rx+
Rx-
Rx-
Gnd
Gnd
12