Page 81

General Specifications

C

VS-06 Smart Camera Guide

C-5

Page 82

Appendix

C

General Specifications

Dimensions FIGURE C–1. VS-06 Smart Camera Dimensions

Note: Nominal dimensions shown. Typical tolerances apply.

C-6

VS-06 Smart Camera Guide

Page 83

Dimensions

C General Specifications

FIGURE C–2. VS-06 C-Mount Smart Camera Dimensions

Note: Nominal dimensions shown. Typical tolerances apply.

VS-06 Smart Camera Guide

C-7

Page 84 read from a scan by OCR; it may hold reading errors

Appendix [f¢# General Specifications

Field of View and Working Distance

20 18 as 45 degree lens £& 16 B 14 > ‘5 12 12) om 10 ~ ri 8 30 degree tens = g °& oO =z 4 _ 2 15 degree lens 0 0 5 10 15 20 25 30

Working Distance (in.)

C-8 VS-06 Smart Camera Guide

Page 85

D D APPENDIX D

Web HMI for VS-06

This appendix contains information about VS-06 support for Visualization HMIs.The VS-06 features a built in runtime monitoring web page that can be viewed from any supported browser on the same network. Supported browsers include: •

Internet Explorer 5.0 or later

•

Firefox 3.0 or later

VS-06 Smart Camera Guide

D-1

Page 86

Appendix

D

Web HMI for VS-06

A built-in runtime HTML monitoring page suitable for HMI Panels that support Internet Explorer 5.0 or later browser such as the SIMATIC M277 Panel is available on the VS-06. Note that the runtime page can also be displayed with the Firefox or Safari web browsers. The Runtime Page shows an image from the VS-06, along with inspection counters and buttons to control certain aspects of the display. A title bar displays the camera name, ip address and resolution. Options are available to change if and where the counters, buttons, and titlebar are displayed. Additionally, up to 10 results values from the job can be displayed along with each image. These values can either be overlayed over the image, or shown as a tabular report underneath the image. All settings and options are set by the user via a series of option pages which can appear over the main display. All parameters are saved as cookies in the web browser environment, so that the next time the Runtime Page is loaded for that device, the layout and settings are retained. The Runtime Image Page is accessed via a URL which contains the IP address of the camera, and optional parameters. The default page is accessed by simply specifying the IP address of the camera in a web browser, for example: http:// 161.218.121.58 (example only, actual IP address of the VS-06 should be used)

D-2

VS-06 Smart Camera Guide

Page 87

If no previous settings have been set by the user, the display will be similar to the following:

Web HMI for VS-06

D

VS-06 Smart Camera Guide

D-3

Page 88

Appendix

D

Web HMI for VS-06

The default behavior is: •

Images and counters are for the first inspection in the job

•

All images (pass & fail) are shown

•

The display is automatically refreshed at regular intervals (auto=on)

•

Graphics are overlaid on the image (note: not all graphics are available)

•

A border is drawn around the image signifying the status of the inspection: green=pass, red=fail

The web page includes the following elements:

D-4

•

Title Bar specifying the name of the camera, IP address, and job (avp) filename. Note that the file extension (.avp) is removed from the displayed filename.

•

Failures Push Button – when this button is selected, only images related to failed inspections are displayed

•

Auto Push Button – when this button is selected, the image and counters are updated automatically. If the button is not selected, both the image and counters are frozen.

•

Refresh Push Button – pushing this button manually updates the image and counters

•

Status – the run status of the inspection – RUNNING or STOPPED

VS-06 Smart Camera Guide

Page 89

Counters – the Total, Pass, Fail and Alarm counters are shown for the selected inspection

Adding Options to the Base URL An option can be specified by adding it to the end of the URL as follows: http://ip_address/?option=value Note the question mark “?” separating the URL from the optional parameter(s). Additional options are specified by separating them with the ampersand “&” character. http://ip_address/?option1=value1&option2=value2&option3=value3

Basic Options NOTE: Some basic options can be changed by specifying optional values at the end of the URL. A much richer superset of these options can be configured by using the Settings Pages described below. It is possible to completely control the behavior of the Runtime Page without the use of optional parameters in the URL. The graphics overlay can be turned on or off by using the “graphics” URL option. This is a setting that can have the value “on” or “off”. As an example, to turn the display of graphics off, the web page can be launched with the following URL: http:// 161.218.121.58/?graphics=off

VS-06 Smart Camera Guide

D-5

D Web HMI for VS-06

•

Page 90

Appendix

D

Web HMI for VS-06

Note: ROI graphics are not produced by applications created by AutoVision. They are displayed for applications created in VisionScape FrontRunner.

Layout Options The overall layout of the Runtime Page can be configured. To change the layout, use the Settings screens as described in the next section. The following shows a default configuration:

D-6

VS-06 Smart Camera Guide