Page 91

The following illustrates that the layout has been changed to position the counters at the top, shown without titles to save room. Additionally, an Options button now appears in the right side area.

Another example with buttons and counters at the top:

VS-06 Smart Camera Guide

D-7

D Web HMI for VS-06

Buttons, status, and counters appear to the right of the image area. The buttons are size for use via a touch screen.

Page 92

Appendix

D

Web HMI for VS-06

It is also possible to hide all elements except the image.

Settings Pages All of the options and settings can be configured by using the settings pages. By default, there is no “Settings” button, so to show the settings pages, the URL should be specified with the “setopt=1” parameter as follows: http://ip_address/?setopt=1 This will display the Runtime Page overlayed with the Options Setup page as follows:

The tabs at the top of the screen can be used to navigate between the several setup pages. To close the setup screens and return to the main display, use the close button (“X”) at the upper right corner.

D-8

VS-06 Smart Camera Guide

Page 93

D Web HMI for VS-06

The Layout page controls many layout features, which are organized into groups. Selecting the Modes group results in the following options being displayed:

Refer to the table below for a description of the various settings. The other groups of settings appear as follows: Image Display:

VS-06 Smart Camera Guide

D-9

Page 94

Appendix

D

Web HMI for VS-06

Buttons:

Counters and Status:

Extra Settings:

D-10

VS-06 Smart Camera Guide

Page 95

D Web HMI for VS-06

As each option is checked or unchecked, the effect can be seen immediately by observing the layout of the Runtime Page shown behind the Options Setup Page.

VS-06 Smart Camera Guide

D-11

Page 96

Appendix

D

Web HMI for VS-06

Clicking the Save button will save these settings so that they become the default behavior the next time the page is launched. Clicking the Defaults button will reset the stored settings to the original defaults the next time the page is launched. The Close button (“X” in upper right corner) will return to the main Runtime Page.

D-12

VS-06 Smart Camera Guide

Page 97

The Report Tab brings up the following Report Setup screen:

Web HMI for VS-06

D

Data Values from datums in the selected inspection can be formatted and overlaid on the displayed image or shown in a table below the image. This is specified by assigning one of 10 data report slots. If overlayed on the image, each of these slots will represent a row in the display area, which is evenly split into 10 equal sized rows. The spacing will depend on the overall size of the display area, which in turn is dependant on the dimensions of the browser window. If the report is shown in list form, each slot corresponds to one of 10 rows. Selecting a slot to configure results in the following display:

VS-06 Smart Camera Guide

D-13

Page 98

Appendix

D

Web HMI for VS-06

At a minimum the path to a datum must be specified. The inspection is implied, so it is not in the path. In the example above, the path Snapshot1.Blob1.BlbFlt1.CentPt is specified in the first slot. This would display the value overlaid over the image near the top of the image display area. If D5 had been used instead, it would appear closer to the center. By default, the displayed format will be appropriate for the datum type requested. However the format can be changed by specifying a printf style format string. The format codes must be consistent with the expected data types. If the result is an integer, then a %d format is expected, floating point numbers require %f type formats. The list of format codes is not documented here, refer to printf documentation. For array values, each element of the array will be passed in turn to the format string. For example, if a PointDm is being used, there are four expected array values corresponding to X, Y, angle, scale. (The order is the same as for variant access via VB). An example of using a format for PointDm: (%.2f,%.2f) angle=%.1f scale=%.1f This will display a result similar to: (23.23,45.10) angle=3.2 scale=1.0 The later array values can be considered optional and can be omitted if desired. For example, to display just the x and y values of a PointDm, use the format string: center = (%6.2f, %6.2f) This will display a result similar to: center = (134.22, 452.12) If no format string is specified, an appropriate default format is used. For example, for a LineDm, by default the datum value will be displayed as: A = value, B = value, C = value

D-14

VS-06 Smart Camera Guide

Page 99

Style style:value,style:value,… For example, set the text size to 9pt, and align to the right, the following can be specified: size:9pt,align:right Possible style values:

It is permitted to use CSS identifiers to alter other display aspects. For example, the following will show a red background color for the text: backgroundColor:red To set some of the more common styles, the combo boxes for Style, Size, Color, and Opacity can be used. The styles field will automatically be updated.

VS-06 Smart Camera Guide

D-15

D Web HMI for VS-06

The default display of a report value is left justified, and uses a default font and color. If desired, all visual aspects of the displayed report value can be modified. If the Style field is used, it has the format:

Page 100

Appendix

D

Web HMI for VS-06

Selecting the URL tab brings up the following display:

The displayed URL can be copied and then used in a browser window to completely replicate the current setup.

Additional Notes:

D-16

•

Line breaks can be inserted into format strings by using embedded HTML codes. To introduce a line break, use “<br />”

•

Commands and options are case sensitive. This is a limitation of javascript and CSS.

•

A new Frontrunner feature allows copying a path of a datum to the clipboard. Right-click the Datum name in the DatumGrid display, and select the “Copy path to clipboard” option.