Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 5 of 18

VS-06 Smart Camera, VS-06 User's Manual, pages 41 to 50

Pages 41 to 50 of 172

The original document is the PDF (3.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the di-soric VS-06

Page 41

Trigger Debounce

Trigger Debounce

Camera Definition File Example IO Line Debounce High Time 2000 IO Line Debounce Low Time 2000

VS-06 Smart Camera Guide

//usecs //usecs

2-27

2 System Components

Trigger Debounce is the ability of the system to accomodate switching noise on a trigger state change – a common issue with relays that have some intermittent contact while engaging. Trigger overruns (when the vision system is triggered faster than the device can process) can be avoided by increasing the “debounce” time in the camera definition file located in the C:\di-soric\Vscape\Drivers\CamDefs directory. The IO Line Debounce High Time and IO Line Debounce Low Time can be added to the file as in the example below. The default debounce time is 1 ms (1,000 μs). Note: Although the value entered for the "IO Line Debounce Time" is in microseconds, it will only be rounded up to a millisecond value. For example, entering the value 1001 will resolve to 2 ms; entering a value of 2800 will resolve to 3 ms. The min value for "IO Line Debounce Time" is 0, which disables software debounce altogether. The maximum value is 100000 (100 ms).

Page 42

Chapter

2-28

2

System Components

VS-06 Smart Camera Guide

Page 43

3 CHAPTER 3

Optics and Lighting 3 This section describes the optical and illumination characteristics of the VS-06 Smart Camera.

VS-06 Smart Camera Guide

3-1

Page 44

Chapter

3

Optics and Lighting

Optics The VS-06 Smart Camera is available with a built-in CMOS sensor or CCD sensor.

Optics Specifications Part Number

VS-06-BM215-ES

VS-06-BM230-ES

VS-06-BM245-ES

VS-06-BC3-15- VS-06-BC3-30- VS-06-BC3-45ES ES ES

Sensor

1/3”, SXGA (1280 x 960) CCD, up to 20 fps

1/3”, WVGA (752 x 480) CMOS, up to 60 fps

Sensor Color

Monochrome

Focal Range

1” (33 mm) to ∞ (liquid lens autofocus)

Shutter

Global Shutter; Exposure: 6μs to 100ms Global Shutter; Exposure: 25μs to 100ms (1/150,000 to 1/10) Default = 666μs (1/1,500) (1/40,000 to 1/10) Default = 400μs (1/2,500)

Part Number

VS-06-BM215-ES

VS-06-BM245-ES

VS-06-BC3-15- VS-06-BC3-30- VS-06-BC3-45ES ES ES

Sensor

1/3”, SXGA (1280 x 960) CCD, up to 20 fps

1/3”, WVGA (752 x 480) CMOS, up to 60 fps

VS-06-BM230-ES

Sensor Color

Monochrome

Focal Range

1” (33 mm) to ∞ (liquid lens autofocus)

Shutter

Global Shutter; Exposure: 6μs to 100ms Global Shutter; Exposure: 25μs to 100ms (1/150,000 to 1/10) Default = 666μs (1/1,500) (1/40,000 to 1/10) Default = 400μs (1/2,500)

Part Number

VS-06-BC3-00- VS-06E-BC3ES 00-ES

Sensor

1/3”, SXGA (1280 x 960) CCD, up to 20 fps

Sensor Color

3-2

VS-06E-BM200-ES

1/3”, WVGA (752 x 480) CMOS, up to 60 fps

VS-06-BM400-ES

VS-06E-BM400-ES

2/3”, WUXGA (2048 x 1088) CMOS, up to 48 fps

Monochrome

Focal Range Shutter

VS-06-BM200-ES

Depends on lens Global Shutter; Exposure: 6μs to 100ms (1/150,000 to 1/10) Default = 666μs (1/1,500)

Global Shutter; Exposure: 25μs to 100ms (1/40,000 to 1/10) Default = 400μs (1/2,500)

Global Shutter; Exposure: 25μs to 100ms (1/40,000 to 1/10) Default = 400μs (1/2,500)

VS-06 Smart Camera Guide

Page 45

Lens Substitution

Lens Substitution The following procedure will change the appropriate settings in the VS-06 to allow the camera to focus properly after the lens has been changed. Please note that the VS-06 camera will use default lookup tables for the focus when the lens selection is changed, so the actual focus distances may not be as accurate as the lens that was shipped with the unit that was factory calibrated. Since default lookup tables are used, the VS-06 may not focus over the full focus range that is normally seen when using the factory calibrated lens. After the lens has been changed via the parameters below, the new values will take effect the next time that the lens focus is modified. 1.

Boot the VS-06 Smart Camera.

2.

Connect to the VS-06 via Telnet using the IP address of the camera.

3.

Send the following command after the VS-06 has booted: stopAll

3

4.

Optics and Lighting

The response should be "value = 1 = 0x1". Send the following command: GetCurrentLense() One of these 3 responses will be seen: 1 = 15deg 2 = 30deg 3 = 45deg 5.

After camera has booted, send the following command (choose the appropriate command based on the lens): SetCurrentLense(1)(to change to 15 degree lens) The response should be: "Now Set to 1 = 15deg" "value = 0 = 0x0"

VS-06 Smart Camera Guide

3-3

Page 46

Chapter

3

Optics and Lighting

SetCurrentLense(2)(to change to 30 degree lens) The response should be: "Now Set to 2 = 30deg" "value = 0 = 0x0" SetCurrentLense(3)(to change to 45 degree lens) The response should be: "Now Set to 3 = 45deg" "value = 0 = 0x0" 6.

Send the following command: startAll The response should be "value = 1 = 0x1"

3-4

VS-06 Smart Camera Guide

Page 47

Illumination

Illumination The standard version of the VS-06 Smart Camera has built-in lighting (red LEDs for SXGA models and white LEDs for QXGA models). The LEDs can be configured to operate in multiple modes – Continuous, Strobe, and Off. Warning: Running a red LED board on a camera with a white LED color profile will damage both the board and the camera. Important: The VS-06 C-Mount does not have built-in lighting. The Machine Vision Lighting Principles on the following page provide some suggestions for how to determine the appropriate external lighting for your application.

Lighting Specifications

VSID-06-BE-3

LED board for VS-06 with integrated lighting, blue color

VSID-06-BE-5

LED board for VS-06 with integrated lighting, white color

VS-06 Smart Camera Guide

3 Optics and Lighting

The VS-06 version with built-in lighting is standardly delivered with a red LED-Lighting board with 617 nm wave length. Optional additional LED-boards as follows:

3-5

Page 48

Chapter

3

Optics and Lighting

Machine Vision Lighting Principles Proper lighting is critical to the success of a machine vision application. Depending on the requirements of your application, you may also need to add external lighting from di-soric NERLITE family of machine vision lighting products. Consider the following when setting up your application: –

Is the surface of the object flat, slightly bumpy, or very bumpy?

–

Is the surface matte or shiny?

–

Is the object curved or flat?

–

What is the color of the object or area being inspected?

–

Is the object moving or stationary?

Machine vision lighting should maximize contrast of the areas or features being inspected while minimizing the contrast of everything else.

Before correct lighting

3-6

After correct lighting

VS-06 Smart Camera Guide

Page 49

4 CHAPTER 4

Using EtherNet/IP 4 This section provides information necessary for using the VS-06 in an EtherNet/IP environment.

VS-06 Smart Camera Guide

4-1

Page 50

Chapter

4-2

4

Using EtherNet/IP