Page 31
Ground and Shield Considerations
Ground and Shield Considerations
VS-06
An earth ground is provided through the cable shields and chassis of the imager.
Ground Loops Ground loops (signal degradation due to different ground potentials in communicating devices) can be eliminated or minimized by ensuring that both the host, imager, and their power supplies are connected to a common earth ground.
VS-06 Smart Camera Guide
2-17
2 System Components
Proper grounding is necessary for operator safety, noise reduction, and the protection of equipment from voltage transients. Buildings, including any steelwork, all circuits, and all junction boxes must be grounded directly to an earth ground in compliance with local and national electrical codes.
Page 32
Chapter
2
System Components
Expected Power and Ground Connections for Proper Operation
Grounding Notes:
2-18
•
Ensure that mounting bracket “Earth” is at the same potential as power source “Earth”.
•
Supply “Return” and “Earth” ground must be stable, low-impedance reference points.
•
“2-Terminal Power Supply” must still provide an “Earth” connection to the imager.
•
“Signal Ground” can be used for communications and/or discrete signal ground reference. It must not be used as Power Ground or Earth Ground.
VS-06 Smart Camera Guide
Page 33
Power Requirements
Power Requirements
TABLE 2–3. Camera Power Requirements
Component VS-06 Smart Camera, CCD, SXGA
5-28VDC, 200mV p-p max ripple, 170mA at 24VDC (typ.) 15.5 watts (max.)
VS-06 Smart Camera, CMOS, WVGA
5-28VDC, 200mV p-p max ripple, 135mA at 24VDC (typ.) 13 watts (max.)
VS-06 C-Mount Smart Camera, CCD, SXGA
5-28VDC, 200mV p-p max ripple, 170mA at 24VDC (typ.) 7 watts (max.)
VS-06 C-Mount Smart Camera, CMOS, WVGA
5-28VDC, 200mV p-p max ripple, 135mA at 24VDC (typ.) 4 watts (max.)
VS-06 C-Mount Smart Camera, CMOS, WUXGA
5-28VDC, 200mV p-p max ripple, 140mA at 24VDC (typ.) 5.7 watts (max.)
VS-06 Smart Camera Guide
2-19
2 System Components
Refer to Table 2-3 when determining the power supply requirements for your camera.
Page 34
Chapter
2
System Components
Status Indicators The top of the VS-06 Smart Camera has multiple LEDs that indicate different trigger, inspection, camera, communication, and power states.
TRIG = Trigger Status PASS/FAIL = Inspection Status MODE = Camera Status
Outputs 1, 2, 3 Power Status
LINK/ACT = Link Activity Status
TRIG
PASS/FAIL MODE
LINK/ACT
PWR OUTPUTS
On Steady
Continuous Trigger
Off
Waiting for Trigger Event
On Flashing
Trigger Event
On
Active State
Off
Inactive State
On Steady
Unit Ready
Off
Unit Not Ready
On Steady
Link Established
Off
No Link/Activity
On Flashing
Link Established and Activity on Link
On
Power On
Off
No Power Applied to Unit
On
Signal Sent to External Output
Off
No Signal Sent to External Output
Additional User Feedback • • •
2-20
Green Flash – A green flash from the front of the unit indicates a Good Read. Red X Targeting Pattern – The red X targeting pattern from the front of the unit allows the user to center an object in the camera’s field of view. Beeper – The beeper is an audible verification that either a Pass or a Fail has occurred.
VS-06 Smart Camera Guide
Page 35
AutoVision Button
AutoVision Button
The AutoVision Button has three positions, selectable by the length of time the button is held down, and indicated by one, two, or three beeps and LED flashes in succession. It can also be used to send a trigger signal when Send Trigger is checked in AutoVision software’s Connect view. When the trigger functionality is enabled, pushing the AutoVision Button triggers the camera to capture an image.
1st Position: Red Targeting Pattern The first AutoVision Button position turns the targeting system on. This overrides any other targeting modes that have been configured.
2nd Position: Auto Calibration The second AutoVision Button position starts the Auto Calibration process, which selects the appropriate photometry and focus settings for the camera. The selected values are then saved for power-on.
3rd Position: Teach The third AutoVision Button position sets the Match String to the next OCR string or symbol data that is decoded.
VS-06 Smart Camera Guide
2-21
System Components
2
Page 36
Chapter
2
System Components
Setting Up a Job in AutoVision AutoVision is a critical component of the VS-06’s functionality. Designed for use with the VS-06, AutoVision provides an intuitive interface, step-bystep configuration, and a library of presets that allow easy setup and deployment. For more complex vision applications, the system can be upgraded from AutoVision to Visionscape. 1.
Configure VS-06 hardware.
1
3
4
2
See Appendix A, Connector Pinouts, for VS-06 pin assignments.
Item Description
Part Number
1
VS-06 Smart Camera
VS-06-BXX-XX-ES
2
Interface Device
VSID-IB-ES
3
Power Supply, M12 12-pin Socket, 1.3 m
VSID-PS-24V-ES
4
Cordset, Host, Ethernet, M12 8-pin Plug to RJ45, 5m
VKHM-Z-5/RJ45
Note: Additional cables available in the di-soric Product Pricing Catalog.
– – – –
2-22
Mount the camera as required by the application. Connect the Ethernet cable from "B" on the camera to the network. Connect the power supply to "3" on the VSID-IB-ES. Connect the photo sensor to "T" on the VSID-IB-ES.
VS-06 Smart Camera Guide
Page 37
Setting Up a Job in AutoVision
– 2.
Connect the "Common" cable to "2" on the VSID-IB-ES and "A" on the camera. Plug in the power supply.
Select your VS-06 in the AutoVision Connect view, create a job, and adjust camera settings. AutoVision's Connect view allows you to select your device and configure its settings, and to create a new job. The Select Device dropdown menu provides a list of available devices. Hover the mouse over a device to see its details.
Click the lock icon to take control of the camera. When you have control of the camera, the Modify button will appear beneath the camera settings. Click the Modify button to adjust camera settings.
VS-06 Smart Camera Guide
2-23
2 System Components
–
Page 38
Chapter
2
System Components
Note: The default IP address of the camera is: 192.168.0.10. Be sure your PC is on the same subnet (192.168.0.100, for example).
Modify camera settings in the Details area at the left of the Connect view. Create, Load, or Upload a job using the buttons in the center of the Connect view.
Important: When modifying camera settings, you will need to enter a username and password for the camera if a password has been defined.
2-24
VS-06 Smart Camera Guide
Page 39
Setting Up a Job in AutoVision
3.
Edit the Job in VS AutoVision. After you have created a new job, loaded a job from your PC, or uploaded a job from the camera, you will proceed to the Edit view to refine your machine vision job. The Camera parameters below the captured image allow you to set Gain, Exposure, Focus, Trigger, and Lighting. Inspection Outputs options allow you to connect your job to the outside world. This is also the view where you can add multiple tools to the job. The tool icons are located above the main view area.
VS-06 Smart Camera Guide
2-25
2 System Components
Once you have selected your camera, adjusted its settings, and created a new job, you will move to the Image view. This view allows you to Auto Calibrate the camera, and to manually adjust the camera's Exposure, Gain, and Focus, and also to set the Lighting Mode (On, Off, or Strobe).
Page 40
Chapter
2-26
2
System Components
4.
Run the Job in AutoVision. Going to the Run view will automatically download your job to the camera and start it running.
5.
Save the Job. Click the Save to Camera icon on the File menu bar to save the job to the VS-06.
VS-06 Smart Camera Guide