Page 31
ACK/NAK mode
> }
Beeps when the 0S20P has read a code.
initializes the timer.
* You may enable or disable the beeper and the CTS control by using the QR-coded parameter menu given in Chapter 7.
CTS High?
Transfers a single character,
No 2 seconds elapsed?
Yes
Beeps if an error occurs. {No transmission possible)
' C »
End
No
Any response received?
Yes NAK
(for trans- mission again)
ACK {normal end)
»
21
End
No One second elapsed?
Yes
Beeps if an error occurs. (No response signal received)
End
Y C >
Page 32
H@ Transmission rate
4800, 9600, 19200, 38400, 57600, or 115200 bps
@ Transferable characters and port settings
If not specified as binary codes, all data will be treated as ASCII codes. Listed below are port settings you can select. If data contains double-byte Japanese Kanji or binary data when the character length is set to 7 bits, the QS20P will ignore the MSB.
Start bit 1 bit (fixed) Character length 7 or 8 bits
Parity check Even, Odd, or None Stop bit 1 or 2 bits
H@ Transmission format
Header Code ID mark No. of digits Data read | Terminator BCC nt n2 | n3 | n4
(1) Header
You may select either "No header" or STX.
(2) Terminator
You may select ETX, CR, LF, or CR LF.
(3) BCC
Every parity bit of BCC (block check character) is set so that all set bits at the same bit level {including a parity bit) in the characters contained in the transmission block have an even number by exclusing-ORing. Those characters do not contain a header but include a terminator.
You may select whether BCC will be transferred. Note that BCC cannot be transferred if the transmission block contains no header.
22
Page 33
(4) Code ID marks
Code ID marks are characters that identify the types of QR codes. You may select whether those ID marks will be transferred, by using the QR-coded parameter menu.
Code type Code ID mark QR code Q Split QR code In edit mode Q ("Structured Append") In non-edit mode S
(5) No. of digits
The number of digits in code data is expressed in 4 bytes. You may select whether it will be transferred, by using the OR-coded parameter menu.
ni: 4th digit (0 to 9) n2: 3rd digit (0 to 9) n3: 2nd digit (0 to 9) n4: ist digit (0 to 9)
(6) Data read
The QS20P will transfer read data whose contents will differ depending upon the code type as described below.
* QR Code All data read
NOTE: If the QS20P reads split QR codes in Non-edit mode, it will transfer not only the read data but the ordinal ID number (a single byte in hex.} assigned to the split code, the number of splits (a single byte in hex.), and parity {double bytes in hex.).
23
Page 34
Appendix. Specifications
Al. QS20P
Power source
External dimensions (W x D x H)
Weight
(Bore: 8 mm)
(Bore: 11 mm)
Lithium-ion battery cartridge (secondary batteries), 3.6 VDC
20 x 162 x 43 mm {0.79 x 6.38 x 1.69 inches)
20 x 169 x 43 mm (0.79 x 6.65 x 1.69 inches) Approx. 70 g (excl. scanner cable)
Approx. 105 g (incl. 0.8-m scanner cable)
Environmental requirements
Operating temperature range
Operating humidity range Ambience
Ambient illuminance
O°C to 40°C
10 to 85% RH {without dew condensation)
Without dust, dirt, or corrosive gases
3000 Jux. or less
Scanning performance
Resolution
Readable codes
Reflection intensity
0.1 mm
OR code Model 1, Model 2, and MicroOR
45% min. for white cells 25% max. for black cells
PCS value: 0.45 min.
Interface
Synchronous system Max. transmission speed
Signal level
Start-stop 115200 bps RS-232C compliant
A2. Power Supply B ox
External dimensions (W x D x H}
Weight
54x 90 x 31mm {2.13 x 3.54 x 1.22 inches)
Approx. 50 g
Environmental requirements
Operating temperature range Operating humidity range
Ambience
0°C to 40°C
10 to 85% RH (without dew condensation)
Without dust, dirt, or corrosive gases
24
Page 35
A3. Interface Requirements
Hi RS-232C interface
Dsub, 9-pin (female) 5 1 oo0a00o o (Sree) © 9 6 Pin No. Signal Functions Signal IN/OUT 2 SD (FXD) Send data Output 3 RD (RXD) Receive data Input 5 SG Signal ground _ 7 CS (CTS) Ready to send Input
@ Wiring example
Shown below is an example of wiring the QS20P up to the PC.
PC aszop
11 | 1 | RD| 2) | 2 |SD SD|3} | 3 jRD
4 [4 | SG/5 | | 5 |SG
| 6 | | 6 | RS| 7 | | 7 |CS
| 8 | | 8 |
[9 | | Dsub, 9-pin Dsub, 9-pin (male) (female)
25
Page 36
@ Interface circuits
Output circuit Input circuit
TXD RXD, CTS
[>o - - - C >) 0 Cc)
RS-232C LEVEL
5K RS-232C LEVEL Voltage polarity Logical value Control level + 0 (space) ON - 1 (mark} OFF
26
Page 37
QR Code Scanner QS20P
User's Manual First Edition, January 2000
DENSO CORPORATION industrial Systems Product Division
The purpose of this manual is to provide accurate information in the handling and operating of the QS20P. Please feel free to send your comments regarding any errors or omissions you may have found, or any suggestions you may have for generally improving the manual.