Page 162

Appendices

Appendix A. Specifications ..................................................................................................... 148 A.1 BHT-6000 ......................................................................................................................... 148 [ 1 ] Product Specifications ........................................................................................... 148 [ 2 ] Bar Code Specifications ......................................................................................... 149 [ 3 ] Interface Specifications .......................................................................................... 153 A.2 CU-6000 ........................................................................................................................... 154 [ 1 ] Product Specifications ........................................................................................... 154 [ 2 ] Charging/Discharging Requirements (CU-6001) .................................................. 154 [ 3 ] Interface Specifications .......................................................................................... 155 Appendix B. A Typical Basic Operation ................................................................................. 156 Appendix C. Alphabet Input Procedure ................................................................................. 157

Appendices

147

Page 163

Appendix A. Specifications A.1

BHT-6000

[ 1 ] Product Specifications Power Source

Main power

• Two alkaline manganese batteries (LR03) or • Rechargeable Ni-MH battery cartridge (2.4 DVC)

Backup power

Integrated lithium battery, 3.0 VDC

Dimensions (W) x (L) x (H)

59 x 135 x 20 mm (2.3 x 5.3 x 0.8 inches)

Weight

Approx. 130 g (Approx. 4.6 oz.) including batteries

Operating Ambient Temperature

-5˚C to 50˚C (23˚F to 122˚F)

Operating Humidity

20% to 80% (with no dew condensation)

Ambient Illuminance

20 to 10,000 lux. (Depth of field: 160 mm, ITF: 1.0 magnification, PCS value: 0.9 min., Reflection intensity: 85% min. for white and 5% max. for black)

Controller

CPU: 16-bit CMOS RAM: 512KB Flash ROM: 512KB/1MB

Keypad

Function keys: 8 Magic keys: 2 Numerical keys and others: 16

Display

Type:

Dot-matrix, FSTN liquid crystal display (LCD) with backlight

Formation:

96 dots wide by 48 dots high

Screen mode Font size

Chars x Lines

Dots (W x H)

Single-byte ANK* mode

Standard-size

16 x 6

6x8

Small-size

16 x 8

6x6

Two-byte Kanji mode

Standard-size

Full-width 6 x 3 Half-width 12 x 3

16 x 16 8 x 16

Small-size

Full-width 8 x 4 Half-width 16 x 4

12 x 12 6 x 12

*ANK: Alphanumerics and Katakana

Calendar Clock

Year, month, day, hour, minute, and second with compensation for leap years

Reading Confirmation LED

Colors: Red and green

148

Page 164

Appendices

[ 2 ] Bar Code Specifications Normal-range Type (1) Available Bar Code Types Bar code type

Bar dimensions

Readable magnification

0.26 to 0.33 mm (10.24 to 13.0 mils) 0.26 to 0.46 m (10.24 to 18.1 mils) 0.26 to 0.33 mm (10.24 to 13.0 mils) 0.26 to 0.56 mm (10.24 to 22.0 mils)

0.8 to 1.0 magnification

2-digit add-on

0.26 to 0.66 mm (10.24 to 26.0 mils)

0.8 to 2.0 magnifications

5-digit add-on

0.26 to 0.66 mm (10.24 to 26.0 mils)

0.8 to 2.0 magnifications

Universal product codes EAN-13 EAN-8 UPC-A UPC-E

0.8 to 1.4 magnifications 0.8 to 1.0 magnification 0.8 to 1.7 magnifications

EAN-13 with supplemental codes EAN-8 with supplemental codes UPC-A with supplemental codes UPC-E with supplemental codes

Interleaved 2 of 5 (ITF)

[Long-range scanning]

0.1 mm min. (3.94 mils min.) PCS value ≥ 0.9 Reflection intensity difference between white and black bars ≥ 80%

Standard 2 of 5 (STF) CODABAR (NW7)

0.15 mm min. (5.91 mils min.) (PCS value ≥ 0.45)

CODE39 CODE93

0.15 mm min. (5.91 mils min.) (PCS value ≥ 0.45)

CODE128

* The above values (except for those for bar codes with supplemental codes) are under the following conditions: • Touch scanning • Ambient illuminance: 500 to 3000 lux. (Xenon lamp)

(2) Optical Properties Required for Bar Code Labels White bars: Reflection intensity

45% min.

Black bars:

25% max. 0.45 min.

Reflection intensity PCS value

149

Page 165

(3) Bar Code Label Size Recommended width: 10 mm min. (0.39 inch min.) Length:

Depth of field (Distance from bar codes to the bar-code reading window)

Length of labels (including margins)

0 mm

39 mm max. (1.54 inches max.) (Minimum narrow bar width: 0.1 mm min.)*1

240 mm (9.45 inches)

235 mm max. (9.25 inches max.) (Minimum narrow bar width: 1.2 mm min.)*4

Length

Width

123456789012345678901234567890121234567890 123456789012345678901234567890121234567890 123456789012345678901234567890121234567890 123456789012345678901234567890121234567890 123456789012345678901234567890121234567890 123456789012345678901234567890121234567890 123456789012345678901234567890121234567890 123456789012345678901234567890121234567890

(4) Thickness of Bars and Depth of Field Minimum narrow bar width

Depth of field

0.15 mm (5.91 mils) 0.26 mm (10.24 mils) 0.33 mm (12.99 mils) 0.64 mm (25.20 mils) 1.0 mm (39.37 mils) 1.2 mm (47.24 mils)

Up to 5 mm (0.19 inch) *2 Up to 36 mm (1.42 inches) *3 Up to 50 mm (1.97 inches) *3 Up to 100 mm (3.94 inches) *4 Up to 200 mm (7.87 inches) *4 Up to 240 mm (9.45 inches) *4 *3 Under the following conditions: • Ambient illuminance: 500 lux. (Xenon lamp) • EAN13 • Reflection intensity of white bars: 85% min. Reflection intensity of black bars: 5% max.

*1 Under the following conditions: • Ambient illuminance: 500 to 3,000 lux. (Xenon lamp) • CODE39, ITF, NW7 • PCS value: 0.9 min. Reflection intensity difference between white and black bars: 80% min. *2 Under the following conditions: • Ambient illuminance: 500 lux. (Xenon lamp) • ITF 20 digits • Reflection intensity of white bars: 85% min. Reflection intensity of black bars: 5% max.

*4 Under the following conditions: • Ambient illuminance: 500 lux. (Xenon lamp) • ITF conforming to the UPC Shipping Container Code • Reflection intensity of white bars: 85% min. Reflection intensity of black bars: 5% max.

150

Page 166

Appendices

Long-range Type (BHT-6000D) (1) Available Bar Code Types Bar code type

Bar dimensions

Readable magnification

0.26 to 0.66 mm (10.24 to 26.0 mils) 0.26 to 0.66 m (10.24 to 26.0 mils) 0.26 to 0.66 mm (10.24 to 26.0 mils) 0.26 to 0.66 mm (10.24 to 26.0 mils)

0.8 to 2.0 magnification

2-digit add-on

0.26 to 0.66 mm (10.24 to 26.0 mils)

0.8 to 2.0 magnifications

5-digit add-on

0.26 to 0.66 mm (10.24 to 26.0 mils)

0.8 to 2.0 magnifications

Universal product codes EAN-13 EAN-8 UPC-A UPC-E

0.8 to 2.0 magnifications 0.8 to 2.0 magnification 0.8 to 2.0 magnifications

EAN-13 with supplemental codes EAN-8 with supplemental codes UPC-A with supplemental codes UPC-E with supplemental codes

Interleaved 2 of 5 (ITF)

0.15 mm min. (5.9 mils min.) PCS value ≥ 0.9 Reflection intensity difference between white and black bars ≥ 80%

Standard 2 of 5 (STF) CODABAR (NW7) CODE39

0.19 mm min. (7.5 mils min.) (PCS value ≥ 0.45)

CODE93 CODE128

* The all above values are under the following conditions: • Depth of field: 68 mm (2.7") • Ambient illuminance: 500 to 3000 lux. (Xenon lamp)

(2) Optical Properties Required for Bar Code Labels White bars: Reflection intensity

45% min.

Black bars:

25% max. 0.45 min.

Reflection intensity PCS value

151

Page 167

(3) Bar Code Label Size Recommended width: 10 mm min. (0.39 inch min.) Length:

Depth of field (Distance from bar codes to the bar-code reading window)

Length of labels (including margins)

68 mm (2.7 inches)

95 mm max. (3.74 inches max.) (Minimum narrow bar width: 0.15 mm min.)*1

350 mm (13.78 inches)

320 mm max. (12.60 inches max.) (Minimum narrow bar width: 1.2 mm min.)*4

Length

Width

123456789012345678901234567890121234567890 123456789012345678901234567890121234567890 123456789012345678901234567890121234567890 123456789012345678901234567890121234567890 123456789012345678901234567890121234567890 123456789012345678901234567890121234567890 123456789012345678901234567890121234567890 123456789012345678901234567890121234567890

(4) Thickness of Bars and Depth of Field Minimum narrow bar width 0.15 mm (5.91 mils) 0.26 mm (10.24 mils) 0.33 mm (12.99 mils) 0.64 mm (25.20 mils) 1.0 mm (39.37 mils) 1.2 mm (47.24 mils)

Depth of field 60 to 80 mm (2.36 to 3.15 inches) *2 40 to 100 mm (1.57 to 3.94 inches) *3 Up to 110 mm (4.33 inches) *3 Up to 150 mm (5.91 inches) *4 Up to 300 mm (11.81 inches) *4 Up to 350 mm (13.78 inches) *4 *3 Under the following conditions: • Ambient illuminance: 500 lux. (Xenon lamp) • EAN13 • Reflection intensity of white bars: 85% min. Reflection intensity of black bars: 5% max.

*1 Under the following conditions: • Ambient illuminance: 500 to 3,000 lux. (Xenon lamp) • CODE39, ITF, NW7 • PCS value: 0.9 min. Reflection intensity difference between white and black bars: 80% min. *2 Under the following conditions: • Ambient illuminance: 500 lux. (Xenon lamp) • ITF 20 digits • Reflection intensity of white bars: 85% min. Reflection intensity of black bars: 5% max.

*4 Under the following conditions: • Ambient illuminance: 500 lux. (Xenon lamp) • ITF conforming to the UPC Shipping Container Code • Reflection intensity of white bars: 85% min. Reflection intensity of black bars: 5% max.

152

Page 168

Appendices

[ 3 ] Interface Specifications Optical Interface Synchronization:

Start-stop

Input signals:

RD

Output signals:

SD

Transmission speed:

115200 bps max.

Direct-connect Interface Synchronization:

Start-stop

Transmission speed:

38400 bps max.

Signal level:

Conforms to the RS-232C interface

Pin assignment:

As shown below.

SD

Pin No.

Signal

1

SG (GND)

2 3

RD

GND

Signal Input/Output External BHT-6000 device

Functions

Ground for signals, SD

Send data

→

RD

Receive data

←

153

Page 169

A.2 CU-6000 [ 1 ] Product Specifications Power Source

12 VDC (via the AC adapter)

Power Consumption

2W

Dimensions (W) x (L) x (H)

82 x 190 x 57 mm (3.23 x 7.48 x 2.24 inches)

Weight

CU-6001: Approx. 240 g (Approx. 8.47 oz.) CU-6002: Approx. 180 g (Approx. 6.35 oz.)

Operating Ambient Temperature

0˚C to 40˚C (32˚F to 104˚F)

Operating Humidity

20% to 80% (with no dew condensation)

[ 2 ] Charging/Discharging Requirements (CU-6001) For charging a Ni-MH battery cartridge loaded in the BHT-6000 Charge current: Charge time:

70 mA Approx. 10 hours

For charging a Ni-MH battery cartridge all by itself Charge current: Charge time: Discharge current: Discharge time:

70 mA Approx. 10 hours 180 mA Approx. 3 hours

154

Page 170

Appendices

[ 3 ] Interface Specifications 13

1

25

14

RS-232C Interface Port (Dsub-25S) on the CU-6000

Pin No.

Signal

1 2 3 4 5 6 7 20

FG SD RD RS CS DR SG ER

NOTE

Signal Input/Output External CU-6000 device

Functions

Frame ground Send data Receive data Request to send Ready to send Data set ready Signal ground Data terminal equipment ready, → ←, - - - - Shown below is a diagram of the internal connection in the CU-6000.

Host computer, modem, or other devices

CU-6000

Signal Name

Pin No.

FG

1

SD

2

RD

3

RS

4

CS

5

DR

6

ER

20

CD

8

SG

7

Optical Interface Not used. RS-232C Interface Circuitry

155

Optical Communications Interface Circuitry

BHT-6000

Page 171

Appendix B. A Typical Basic Operation What follows is a typical basic operation which helps you instruct the hands-on user in practical bar-code reading operation. Application type: Inventory Operation:

Power ON → Read the bar code on stock (A). → Key in the quantity. Read the bar code on stock (B). → Key in the quantity.

. ..

Repeat the above operation.

.. . 6. Ready for data entry Record 00100 scrolls up so that record 00101 becomes ready for next data entry.

File1 A:

96/10/20

MULTI K 00101

4. Display of read data

A:0031323120786 B: MULTI K 00100 2. Ready for data entry

File1 A:

96/10/20 5. Quantity entry Enter the quantity by pressing the numerical keys, then press ENT key.

MULTI K 00100

A:0031323120786 B:20 3. Bar code entry Bring the bar-code reading window to the bar code to be scanned and press M1 key.

MULTI K 00100

1. Power ON Press PW key to turn on the power.

156

Page 172

Appendices

Appendix C. Alphabet Input Procedure To activated or deactivate the alphabet input function, issue OUT statement in a user program. As shown at right, each of 0-9 numerical keys and period key is assigned three characters. For example, the 7 key is assigned A, B, and C. To designate one of three assigned characters, use the M1 or M2 key. Note that the trigger switch function (default) or no function should be assigned to the M1 or M2 key to be used.

ABC

DEF

GHI

JKL

MNO

PQR

STU

VWX

Y Z sp

+-*

/$%

Alphabet input procedure (1)

Activating the alphabet input function with OUT statement In a user program, issue the OUT statement which sets 1 to bit 0 of port 5. (To deactivate the function, issue the OUT statement which sets 0 to bit 0 of port 5.) To activate: To deactivate:

OUT 5, &h1 OUT 5, &h0

The default setting of the alphabet input function is "deactivated." (2)

Entering alphabetic characters from the keypad 1) Find a target key which is assigned an alphabetic character to be inputted, and then check the position of the character (Left, Center, or Right) relative to the three characters assigned to the target key. 2) Designate the character position by using the M1 or M2 key and then press the target key. How to use the M1 or M2 key Pressing the M1 or M2 key cycles through the shift guidance blocks Left , Center , and Right on the LCD as shown below.

Left

Center

Right

157

The shift guidance block will appear on the top or bottom line, depending upon the current cursor position. That is, if the cursor lies on any of the lower lines, the shift guidance block will appear on the top line; if it lies on any of the upper lines, the block will appear on the bottom line.

Page 173

The shift guidance block appears only while the M1 or M2 key is held down. Therefore, you should press the target key while holding down the M1 or M2 key. To enter an N character, for example, use the M1 or M2 key to display the Center on the LCD. While displaying the Center , press the 5 key.

NOTE

• During the alphabet input operation, you can use the BS , C , and numerical keys as usual. • For displaying the shift guidance block Right when the status indication is set to ON, the BHT-6000 overwrites the status indication with the shift block. • The activated or deactivated state of the alphabet input function will be resumed. The shift block will not be resumed.