Page 148

Chapter 5. Handling the CU-6000 (Option)

This chapter describes the handling procedure of the CU-6000, the interfacing with the host computer, and the charging of the Ni-MH battery cartridge.

5.1

Functions of the CU-6000 .............................................................................................. 134

5.2

Components and Functions .......................................................................................... 134

5.3

Applying Power to the CU-6000 .................................................................................... 136

5.4

Communicating with the Host Computer .................................................................... 137

5.4.1

Setting the Transmission Speed of the CU-6000 .................................................... 137

5.4.2

Interface Cable Connection ...................................................................................... 137

5.4.3

Interfacing with the Host Computer ........................................................................ 138

5.5

Charging the Ni-MH Battery Cartridge (using the CU-6001) ....................................... 139

5.5.1

Ni-MH Battery Cartridge Loaded in the BHT-6000 .................................................. 139

5.5.2

Ni-MH Battery Cartridge Alone ................................................................................ 141

[ 1 ] Fully Discharging (Refresh) and then Charging ................................................... 142 [ 2 ] Charging Only ......................................................................................................... 143 5.6

RS-232C Interface Specifications .................................................................................. 144 [ 1 ] Interface Connector and Pin Assignment ............................................................. 144 [ 2 ] Interface Cable Connection .................................................................................... 145

Chapter 5 Handling the CU-6000 (Option)

133

Page 149

5.1 Functions of the CU-6000 The optical communications unit CU-6000 is available in two models: CU-6001 and CU6002. The CU-6001 has both of functions (1) and (2) given below; the CU-6002 has only function (1). (1)

Data exchange function The CU-6001/CU-6002 exchanges data and programs between the BHT-6000 and the host computer. It interfaces with the BHT-6000 via the optical interface and with the host computer via the RS-232C interface.

(2)

Ni-MH battery cartridge charging function The CU-6001 charges the Ni-MH battery cartridge.

5.2 Components and Functions • BHT-6000 charge terminals (Not provided on CU-6002) Do not stain these terminals; failure to protect the terminals may result in decreased charging efficiency. • Optical interface port Used to exchange data optically with the BHT-6000.

• Status indicator (Not provided on CU-6002)

• RS-232C interface port Used to exchange data with the host computer.

• Power switch

• Power inlet connector Plug the AC adapter into this connector.

134

Page 150

Chapter 5. Handling the CU-6000 (Option)

Status indicator (Not provided on CU-6002) Shows the status of the CU-6001. POWER LED (green) Lights when the power is applied to the CU-6000.

POWER DATA

CHG1 CHG2

DATA communications LED (green) Lights when the BHT-6000 is communicating with the host computer. CHG2 LED (Battery cartridge charge lamp) (yellow) Lights when the CU-6001 is charging a Ni-MH battery cartridge all by itself. Upon completion of charging, this LED flashes at 2-second intervals. During discharging of a Ni-MH battery cartridge, this LED flashes at 0.4-second intervals. CHG1 LED (BHT-6000 charge lamp) (yellow) Lights when the CU-6001 is charging a Ni-MH battery cartridge loaded in the BHT-6000. Upon completion of charging, this LED flashes at 2second intervals.

Battery cartridge slot (Not provided on CU-6002) To charge a Ni-MH battery cartridge all by itself, load it into this slot.

135

Page 151

5.3 Applying Power to the CU-6000 Apply power to the CU-6000 by connecting it to the wall socket via the attached AC adapter according to the steps given below. (1)

Make sure that the CU-6000 is turned off.

(2)

Connect the outlet plug of the AC adapter to the power inlet connector of the CU6000, then plug the other end of the AC adapter into the wall socket. AC adapter

Power switch Power inlet connector

(3)

Power on the CU-6000.

WARNING

• If smoke, abnormal odors or noises come from the CU, immediately turn off the power, unplug the AC adapter from the wall socket, and contact your nearest dealer. Failure to do so could cause fire or electrical shock. • If foreign material or water gets into the CU, immediately turn off the power, unplug the AC adapter from the wall socket, and contact your nearest dealer. Failure to do so could cause fire or electrical shock. • If you drop the CU so as to damage its housing, immediately turn off the power, unplug the AC adapter from the wall socket, and contact your nearest dealer. Failure to do so could cause fire or electrical shock. • Use the furnished AC adapter only. Failure to do so could result in a fire. • Never use the CU on the line voltage other than the specified level. Doing so could cause the CU to break or burn. • If the power cord of the AC adapter is damaged (e.g., exposed or broken lead wires), stop using it and contact your nearest dealer. Failure to do so could result in a fire or electrical shock.

CAUTION

• If you are not using the CU for a long time, be sure to unplug the AC adapter from the wall socket for safety. Failure to do so could result in a fire. • When caring for the CU, unplug the AC adapter from the wall socket for safety. Failure to do so could result in an electrical shock. • Never cover or wrap up the CU or AC adapter in a cloth or blanket. Doing so could cause the unit to heat up inside, deforming its housing, resulting in a fire. Always use the CU and AC adapter in a well-ventilated area. • Keep the power cord away from any heating equipment. Failure to do so could melt the sheathing, resulting in a fire or electrical shock.

136

Page 152

Chapter 5. Handling the CU-6000 (Option)

5.4 Communicating with the Host Computer 5.4.1 Setting the Transmission Speed of the CU-6000 Set the transmission speed of the CU-6000 to the same value as that of the BHT-6000 and the host computer, by using the DIP switch provided on the bottom of the CU6000. (1)

Turn the CU-6000 upside down.

(2)

Remove the protection sheet of the DIP switch from the CU-6000.

(3)

Set the selectors of the DIP switch as shown below. For 115,200 bps ON OFF

1 2 3 OFF

For 38,400 bps

ON OFF

Protection sheet (Inside this sheet is a DIP switch.)

ON

NOTE

ON OFF

OFF

For 19,200 bps

ON

OFF

1 2 3

1 2 3

OFF

OFF

For 9,600 bps (Factory setting) Bottom View

(4)

1 2 3

For 57,600 bps

OFF

1 2 3 OFF

Reinstall the protection sheet.

Do not set the DIP switch to any configurations other than one of the five shown above.

5.4.2 Interface Cable Connection (1)

Make sure that both the CU-6000 and the host computer are turned off.

(2)

Connect the 25-pin plug (Dsub-25P) of the interface cable to the RS-232C interface port of the CU-6000.

RS-232C interface cable

(3)

Connect the other end of the interface cable to the host computer.

137

Page 153

5.4.3 Interfacing with the Host Computer (1)

Power on the host computer and start up the MS-DOS.

(2)

Turn on the power switch of the CU-6000.

(3)

Make sure that the BHT-6000 is turned off, then put it on the CU-6000.

(4)

Power on the BHT-6000 and run System Mode. Set the communications environments (communications protocol, interface port, communications parameters, and protocol options). Regarding the communications protocol: When using Ir-Transfer Utility C on the host computer, select the BHT-Ir protocol; when using Transfer Utility, select the BHT-protocol. Regarding the interface port: Select the optical interface port.

(5)

On the host computer, initiate a communications program (e.g., Ir-Transfer Utility C, Transfer Utility, or equivalent).

(6)

To transfer data stored in the BHT-6000 to the host computer, select "3: UPLOAD" on the SYSTEM MENU in System Mode. To transfer data from the host computer to the BHT-6000, select "2: DOWNLOAD." (For details, refer to Chapter 2, Section 2.5.) The BHT-6000 and the host computer will start communications with each other via the CU-6000. (On the CU-6001, the DATA LED will come on upon start of communications. After completion of communications, the LED will go off.)

(7)

Power off the BHT-6000, CU-6000, and the host computer.

138

Page 154

Chapter 5. Handling the CU-6000 (Option)

5.5 Charging the Ni-MH Battery Cartridge (using the CU-6001) You may charge Ni-MH battery cartridges either loaded in the BHT-6000 or all by themselves.

NOTE

Service Life of Ni-MH Battery Cartridge: Ni-MH batteries used in the battery cartridge will gradually deteriorate during the repeated cycles of charging and discharging due to its properties, even under normal use. When the battery service period becomes shortened due to its deterioration even if it has been charged for the specified hours, replace the battery cartridge with a new one. Generally, it is necessary to replace the battery cartridge after it has undergone approx. 200 cycles of charging and discharging operation. Memory Effect: If a Ni-MH battery undergoes many cycles of imperfect charging and discharging (e.g., one-hour recharge followed by one-hour use), the service period may become shortened before the service life is really expired, just as the battery memorizes the use conditions. It is called "Memory Effect." The memory effect can be avoided by discharging a Ni-MH battery fully before charging. For the Ni-MH battery cartridge, use the CU-6001 or C-600 for fully discharging and recharging.

5.5.1 Ni-MH Battery Cartridge Loaded in the BHT6000 (1)

Turn on the CU-6001.

(2)

Place the BHT-6000 loaded with a Ni-MH battery cartridge onto the CU-6001. The CU-6001 lights the CHG1 LED and starts charging. After approx. ten hours of charging, the CHG1 LED starts flashing at 2-second intervals, indicating that charging is completed. BHT-6000

CU-6001

139

Page 155

■ Charging Operation and LED Indication LED Indication

Operator's Action

CU-6001 Status

Power on the CU-6001.

On standby

POWER DATA

⇓

⇓

CHG1 CHG2

Place the BHT-6000 on the CU-6001.

Ordinary charging

POWER DATA

⇓

⇓

After approx. 10 hours

Trickle charging*

⇓

⇓

ON

ON

CHG1 CHG2

ON ON POWER DATA

CHG1 CHG2

Flashing at 2-second intervals ON

Remove the BHT-6000.

On standby

POWER DATA

CHG1 CHG2

OFF

* "Trickle charging" is a slow continuous charge for a battery, which compensates for the slight amount of discharge happening even when batteries are not in use.

140

Page 156

Chapter 5. Handling the CU-6000 (Option)

5.5.2 Ni-MH Battery Cartridge Alone

Ni-MH battery cartridge

The CU-6001 can charge Ni-MH battery cartridges in either of the following two ways: - Fully discharging and then charging*

[1]

- Charging only

[2] * Fully discharging and then charging batteries can prevent "Memory Effect" as described at the beginning of Section 5.5.

To select [ 1 ], first power on the CU-6001 and then load a Ni-MH battery cartridge into it. To select [ 2 ], first load a Ni-MH battery cartridge into the CU-6001 and then power it on.

WARNING

• Never use the CU-6001 for charging anything other than the specified battery cartridges. Doing so could cause heat, battery-rupture, or fire.

CAUTION

Handling the battery cartridge • Never charge a wet or damp Ni-MH battery cartridge. Doing so could cause the batteries to break, generate heat, rupture, or burn. • Do not insert or drop foreign materials such as metals or anything inflammable through the openings (vents or battery cartridge slot) into the CU-6000. Doing so could result in a fire or electrical shock.

141

Page 157

[ 1 ] Fully Discharging (Refresh) and then Charging (1)

Power on the CU-6001. The POWER LED comes on.

(2)

Load a Ni-MH battery cartridge into the CU-6001 from the battery cartridge slot. The CU-6001 flashes the CHG2 LED at 0.4-second intervals and starts discharging the cartridge. The discharging time differs depending upon the battery condition, but never more than three hours. Upon completion of discharging, the CHG2 LED comes to stay on and the CU6001 starts charging. After approx. ten hours of charging, the CHG2 LED starts flashing at 2-second intervals, indicating that the charging is completed.

(3)

Take out the battery cartridge.

■ Discharging & Charging Operations and LED Indication LED Indication

Operator's Action

CU-6001 Status

Power on the CU-6001.

On standby

POWER DATA

⇓

⇓

CHG1 CHG2

Load a battery cartridge into the CU-6001.

Discharging

POWER DATA

⇓

⇓

After discharging

Ordinary charging

POWER DATA

⇓

⇓

CHG1 CHG2

ON

ON

CHG1 CHG2

Flashing at 0.4-second intervals ON

ON ON

After approx. 10 hours

Trickle charging

POWER DATA

⇓

⇓

CHG1 CHG2

Flashing at 2-second intervals ON

Take out the battery cartridge.

On standby

POWER DATA

CHG1 CHG2

OFF

142

Page 158

Chapter 5. Handling the CU-6000 (Option)

[ 2 ] Charging Only (1)

Load a Ni-MH battery cartridge into the CU-6001 from the battery cartridge slot.

(2)

Power on the CU-6001. The CU-6001 turns on the CHG2 LED and starts charging the cartridge. After approx. ten hours of charging, the CHG2 LED starts flashing at 2-second intervals, indicating that the charging is completed.

(3)

Take out the battery cartridge.

■ Charging Operation and LED Indication LED Indication

Operator's Action

CU-6001 Status

Load a battery cartridge into the CU-6001.

Powered OFF

POWER DATA

⇓

CHG1 CHG2

Power on the CU-6001.

Ordinary charging

POWER DATA

⇓

⇓

CHG1 CHG2

⇓ ON

ON ON

After approx. 10 hours

Trickle charging

POWER DATA

⇓

⇓

CHG1 CHG2

Flashing at 2-second intervals ON

Take out the battery cartridge.

On standby

POWER DATA

CHG1 CHG2

OFF

143

Page 159

5.6 RS-232C Interface Specifications [ 1 ] Interface Connector and Pin Assignment The CU-6000 has an RS-232C interface port (Dsub-25S). 13

1

25

14

RS-232C interface port (Dsub-25S) on the CU-6000

Pin No.

Signal

1 2 3 4 5 6 7 20

FG SD RD RS CS DR SG ER

Functions

Signal Input/Output CU-6000 External device

Frame ground Send data Receive data Request to send Ready to send Data set ready Signal ground Data terminal equipment ready, → ←, - - - - The input/output voltage threshold for the logical valued signal is listed below. Logical Value

Input Voltage Threshold

Output Voltage Threshold

0

3V min.

5V min.

1

-3V max.

-5V max.

144

Page 160

Chapter 5. Handling the CU-6000 (Option)

[ 2 ] Interface Cable Connection As illustrated below, connect the CU-6000 (which is joined with the BHT-6000) to a host computer with a cross-mode cable. To connect it to a modem, use a straight-mode cable. CU-6000 (DTE)

Host Computer (DTE)

1

FG SD RD RS CS DR SG CD ER

2 3 4 5 6 7 8 20

Cable Connection between CU-6000 and Host Computer

Modem (DCE)

CU-6000 (DTE)

1

FG SD RD RS CS DR SG CD ER

2 3 4 5 6 7 8 20

Cable Connection between CU-6000 and Modem

DTE and DCE In the RS-232C interface specifications, the DTEs (Data Terminal Equipment) shall be generally connected with each other by a cross-mode cable; the DTE and DCE (Data Circuit-terminating Equipment) shall be connected with each other by a straight-mode cable. The DTE is one piece of equipment connected at both ends of a communications line as a sender or receiver of data (such as CU-6000 joined with the BHT-6000 and a host computer). The DCE is one piece of equipment connected to the intermediate point between the DTE and the communications line. It terminates communications lines and exchanges information between those lines without any change in contents (such as modem).

145

Page 161

146