The text of a manual · part 9 of 20
Bar Code Handy Terminal BHT-7000 User's Manual: Chapter 2 Getting Started the BHT-7000 and System Mode, pages 63 to 72
Pages 63 to 72 of 175, from Bar Code Handy Terminal BHT-7000 User's Manual
The original document is the PDF (934 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Denso BHT-7000
Page 63
Chapter 2. Getting Started the BHT-7000 and System Mode
[ 4 ] System Environment Setting SET SYSTEM 1:EXECUTE PROGRAM 2:DISPLAY 3:DATE/TIME 4:BARCODE 5:COMMUNICATION 6:KEY 7:RESUME
Selecting "4: SET SYSTEM" on the SYSTEM MENU calls up the screen shown at left. 1 EXECUTE PROGRAM : Sets an execution program to be run when the power is turned on. 2 DISPLAY
: Sets the message version (English or Japanese).
3 DATE/TIME
: Sets the calendar clock (date and time).
4 BARCODE
: Sets the special barcode scanning parameters (the black-andwhite inverted label reading and the decoding level) and the minimum number of digits to be read for bar codes (ITF, STF and CODABAR).
5 COMMUNICATION
: Sets the communications environments (interface port and communications parameters).
6 KEY
: Defines the functions of the shift key and magic keys.
7 RESUME
: Sets the resume function.
Select a desired item by using the numerical keys or * and * keys, and the selected item becomes highlighted. Then press the ENT key. Press the C key to return to the SYSTEM MENU.
* For BHT-7000s having a 26-key pad, use F5 , F6 , F7 and F8 keys instead of , and keys, respectively
47
,
,
Page 64
[4.1]
Setting an execution program
SET EXECUTE PROGRAM SAMPLE01.PD3 SAMPLE02.PD3 SAMPLE03.PD3 SAMPLE04.PD3
Selecting "1: EXECUTE PROGRAM" on the SET SYSTEM menu calls up the screen shown at left. Highlighted is the current setting. Use the * and * keys to move the cursor to a desired execution program to be run when the power is applied, and then press the ENT key. To return to the SET SYSTEM menu, press the C key.
SET EXECUTE PROGRAM
If no program files are stored in the memories, the screen shown at left will appear.
****************** * NO FILE EXISTS * ******************
To return to the SET SYSTEM menu, press the C key.
[4.2]
Setting the message version SET DISPLAY
Selecting "2: DISPLAY" on the SET SYSTEM menu calls up the screen shown at left.
MESSAGE Highlighted is the current setting. English Japanese MESSAGE:
Switches the message version to English or Japanese for system error messages and indications on the LCD contrast, beeper volume, beeper & vibrator switching, and battery voltage level screens. (The default is the message version that you selected in the initializing sequence.)
Select a desired setting by using the keys.
* and
*
Press the ENT key. To return to the SET SYSTEM menu, press the C key.
* For BHT-7000s having a 26-key pad, use F5 , F6 , F7 and F8 keys instead of , and keys, respectively
48
,
,
Page 65
Chapter 2. Getting Started the BHT-7000 and System Mode
[4.3]
Setting the calendar clock
SET DATE/TIME
Selecting "3: DATE/TIME" on the SET SYSTEM menu calls up the screen shown at left.
00/01/01 00:00
Use the numerical keys to enter the year (only the last two digits), month, day, hour, and minute in this order, and then press the ENT key. If the data is in one digit, add a 0 (zero) preceding the data.
_ /
/
:
NOTE
For the year, be sure to enter the last two digits of the year. For the hour, enter it in the 24-hour format. If any of the year, month, day, hour, and minute is not entered, the ENT key will be deactivated.
⇓
If you make a wrong entry, press the backspace key to delete it and then enter the correct data. To return to the SET SYSTEM menu, press the C key.
SET DATE/TIME
[Example] To set 1999, August 19, at 4:00 p.m. Press 9 , 9 , 0 , 8 , 1 , 9 , 1 , 6 , 0 , and 0 .
00/01/01 00:00 99/08/19 16:00_
⇓ SET DATE/TIME
Press the ENT key to register the above setting.
99/08/19 16:00 _ /
/
:
49
Page 66
[4.4]
Setting the special bar-code scanning parameters
SET BARCODE 1:INVERT ON OFF 2:DECODE LEVEL X MINIMUM DIGITS 3:ITF XX 4:STF XX 5:CODABAR XX 6:MARKER X
Selecting "4: BARCODE" on the SET SYSTEM menu calls up the screen shown at left. Highlighted is the current setting. 1 INVERT
: Activates or deactivates the black-and-white inverted label reading function.
2 DECODE LEVEL : Sets the decode level. 3 ITF
: Sets the minimum number of digits to be read for ITF.
4 STF
: Sets the minimum number of digits to be read for STF.
5 CODABAR
: Sets the minimum number of digits to be read for CODABAR.
6 MARKER
: Sets the marker ON/OFF mode.
Select a desired item by using the numerical keys or * and * keys, and then select a desired * and * keys. setting by using the To increase the decode level, press the * key. to decrease it, press the
* key;
To increase the number of digits to be read for ITF, STF and CODABAR, press the * key; to de* key. crease it, press the Press the ENT key. To return to the SET SYSTEM menu, press the C key.
Black-and-white inverted label reading function (INVERT) This function makes it possible to read white bars on a black background.
NOTE
Activating this function might increase the frequency of bar-code reading errors. This function can usually be set to OFF.
DECODE LEVEL You may set the decode level. Decreasing the level value increases the bar-code reading efficiency, but the BHT-7000 might misread low-quality bar codes (split or stained). To the contrary, increasing the level value decreases the bar-code reading efficiency, but it will disminish the possibility of misreading. The setting range of the level value is from 1 to 9 and the default is 4.
* For BHT-7000s having a 26-key pad, use F5 , F6 , F7 and F8 keys instead of , and keys, respectively
50
,
,
Page 67
Chapter 2. Getting Started the BHT-7000 and System Mode
Minimum number of digits to be read for ITF, STF, or CODABAR (MINIMUM DIGITS) You may determine the minimum number of digits to be read for ITF, STF, and CODABAR. Setting a small number of digits increases the frequency of digit-missing reading or misreading depending upon how to scan bar codes or the quality of bar codes. On the other hand, setting a large number will diminish the possibility of those errors. The setting range is from 2 to 20 for ITF, from 1 to 20 for STF, and from 3 to 20 for CODABAR. The default is 4 for ITF and CODABAR, and 2 for STF.
MARKER You may select either of the following ON/OFF modes of a laser beam (marker) which indicates the scanning range: 0: Normal mode (in which the laser and illumination LED come on at the same time at the time of scanning) 1: OFF mode (in which no laser comes on)
TIP
Even if the MARKER is set to 0 (Normal mode), the marker will not come on when the read mode is set to the alternate switching mode or continuous reading mode.
51
Page 68
[4.5]
Setting the communications environments
After the BHT-7000 is initialized, the interface port and communications parameters are set as listed in the default table below. Do not access them unless necessary. Interface port
Optical (Optical interface port)
Communications protocol
BHT-protocol Defaults
Communications parameters for the optical interface port TRANSMIT SPEED
9600 bps
PROTOCOL (Protocol options)
SERIAL No.:
ON (Adds serial numbers to data blocks.)
H. PARITY:
ON (Adds a horizontal parity.)
LINKUP TIME:
30 seconds
FIELD SPACE:
Ignore
Listed below are the default communications parameters for the direct-connect interface. Defaults
Communications parameters for the direct-connect interface port TRANSMIT SPEED
19200 bps
PARITY BIT (Vertical parity)
None
DATA BIT (Character length)
8 bits
STOP BIT
1 bit
PROTOCOL (Protocol options)
SERIAL No.:
ON (Adds serial numbers to data blocks.)
H. PARITY:
ON (Adds a horizontal parity.)
LINKUP TIME:
30 seconds
FIELD SPACE:
Ignore
52
Page 69
Chapter 2. Getting Started the BHT-7000 and System Mode
SET COMMUNICATION 1:OPTICAL 2:CONNECTOR 3:COM PORT 4:PROTOCOL TYPE
Selecting the "5: COMMUNICATION" on the SET SYSTEM menu calls up the screen shown at left. 1 OPTICAL:
Switches to the communications parameters setting screen for the optical interface.
2 CONNECTOR:
Switches to the communications parameters setting screen for the direct-connect interface.
3 COM PORT:
Switches to the interface port setting screen.
4 PROTOCOL TYPE:
Switches to the communications protocol type setting screen.
Select a desired screen by using the numerical keys or * and * keys, and then press the ENT key. To return to the SET SYSTEM menu, press the C key.
[4.5-1]
Setting the communications parameters for the optical interface
SET OPTICAL
Selecting "1:OPTICAL" on the SET COMMUNICATION menu calls up the screen shown at left.
1:PARAMETER 2:PROTOCOL
1 PARAMETER:
Switches to the communications parameters setting screen.
2 PROTOCOL:
Switches to the communications protocol option screen.
Select a desired screen by using the numerical keys or * and * keys, and then press the ENT key. To return to the SET COMMUNICATION menu, press the C key.
* For BHT-7000s having a 26-key pad, use F5 , F6 , F7 and F8 keys instead of , and keys, respectively
53
,
,
Page 70
(1)
Communications parameters setting screen
SET PARAMETER < OPTICAL > 1:TRANSMIT SPEED: 2400 9600 19200 38400 57600 115200
Selecting "1:PARAMETER" on the SET OPTICAL screen calls up the screen shown at left. Highlighted is the current setting. Select the desired transmission speed by using the numerical keys or * and * keys, and then press the ENT key. To return to the SET OPTICAL screen, press the C key.
(2)
Communications protocol option screen
SET PROTOCOL < OPTICAL > 1:SERIAL No. : ON OFF 2:H.PARITY : ON OFF 3:LINKUP TIME: None 30 60 90 120 4:FIELD SPACE: Ignore Data
Selecting "2: PROTOCOL" on the SET OPTICAL screen calls up the screen shown at left. Highlighted is the current setting. 1 SERIAL No.:
Selects whether or not the system will add serial numbers to data blocks.
2 H. PARITY:
Selects whether or not the system will add a horizontal parity.
3 LINKUP TIME:
Selects the timeout length (in seconds) to be applied when a link is to be established.
4 FIELD SPACE:
Selects whether space codes in the tail of a data field will be ignored or handled as data.
Select a desired item by using the numerical keys or * and * keys. Then select a desired setting by using the * and * keys. To return to the SET OPTICAL screen, press the C key.
NOTE
If the BHT-Ir protocol has been selected, the serial number and horizontal parity settings will be ignored.
* For BHT-7000s having a 26-key pad, use F5 , F6 , F7 and F8 keys instead of , and keys, respectively
54
,
,
Page 71
Chapter 2. Getting Started the BHT-7000 and System Mode
[4.5-2]
Setting the communications parameters for the direct-connect interface
SET CONNECTOR
Selecting "2:CONNECTOR" on the SET COMMUNICATION menu calls up the screen shown at left.
1:PARAMETER 2:PROTOCOL
1 PARAMETER:
Switches to the communications parameters setting screen.
2 PROTOCOL:
Switches to the communications protocol screen.
Select a desired screen by using the numerical * and * keys, and then press the keys or ENT key. To return to the SET COMMUNICATION menu, press the C key.
(1) Communications parameters setting screen
SET PARAMETER < CONNECTOR > 1:TRANSMIT SPEED: 300 600 1200 2400 4800 9600 19200 38400 57600 115200 2:PARITY BIT : N O E 3:DATA:7 8 4:STOP:1 2
Selecting "1:PARAMETER" on the SET CONNECTOR screen calls up the screen shown at left. Highlighted is the current setting. 1 TRANSMIT SPEED: Sets the transmission speed. 2 PARITY BIT:
Sets the vertical parity: none, odd, or even.
3 DATA:
Sets the character length.
4 STOP:
Sets the stop bit length.
Select a desired item by using the numerical keys or * and * keys. Then select a desired set* and * keys. ting by using the To return to the SET CONNECTOR screen, press the C key.
NOTE
If the BHT-Ir protocol has been selected, the parity bit, character length, and stop bit length settings will be ignored.
* For BHT-7000s having a 26-key pad, use F5 , F6 , F7 and F8 keys instead of , and keys, respectively
55
,
,
Page 72
(2)
Communications protocol option menu
SET PROTOCOL < CONNECTOR > 1:SERIAL No. : ON OFF 2:H.PARITY : ON OFF 3:LINKUP TIME : None 30 60 90 120 4:FIELD SPACE: Ignore Data
Selecting "2:PROTOCOL" on the SET CONNECTOR screen calls up the screen shown at left. Highlighted is the current setting. 1 SERIAL No.:
Selects whether or not the system will add serial numbers to data blocks.
2 H. PARITY:
Selects whether or not the system will add a horizontal parity.
3 LINKUP TIME:
Selects the timeout length (in seconds) to be applied when a link is to be established.
4 FIELD SPACE:
Selects whether space codes in the tail of a data field will be ignored or handled as data.
Select a desired item by using the numerical keys or * and * keys. Then select a desired set* and * keys. ting by using the To return to the SET CONNECTOR screen, press the C key.
NOTE
If the BHT-Ir protocol has been selected, the serial number and horizontal parity settings will be ignored.
* For BHT-7000s having a 26-key pad, use F5 , F6 , F7 and F8 keys instead of , and keys, respectively
56
,
,