Page 73

Chapter 2. Getting Started the BHT-7000 and System Mode

[4.5-3]

Setting the interface port

SET COM DEFAULT PORT

Selecting the "3:COM PORT" on the SET COMMUNICATION menu calls up the screen shown at left.

1:BASIC Optical Connector 2:SYSTEM MODE Optical Connector

Highlighted is the current setting. 1 BASIC:

Selects the optical or directconnect interface port to be used for user programs written in BHT-BASIC (OPEN "COM:" or XFILE statement).

2 SYSTEM MODE:

Selects the optical or directconnect interface port to be used for downloading or uploading files in System Mode.

Select a desired item by using the numerical keys or * and * keys, and then select a desired setting by using the * and * keys. To return to the SET COMMUNICATION menu, press the C key.

* For BHT-7000s having a 26-key pad, use F5 , F6 , F7 and F8 keys instead of , and keys, respectively

57

,

,

Page 74

[4.5-4]

Setting the communications protocol type

1:BHT Protocol

Selecting the "4:PROTOCOL TYPE" on the SET COMMUNICATION menu calls up the screen shown at left.

2:BHT-Ir Protocol

Highlighted is the current setting.

PROTOCOL TYPE

1 BHT Protocol:

Selects the BHT-protocol for downloading or uploading files in System Mode or for the execution of XFILE statement in BHT-BASIC. This protocol should be selected for file transmission with Transfer Utility.

2 BHT-Ir Protocol: Selects the BHT-Ir protocol for downloading or uploading files in System Mode or for the execution of XFILE statement in BHT-BASIC. This protocol should be selected for file transmission with Ir-Transfer Utility C/IrTransfer Utility E. SET ID

Select a desired item by using the numerical keys * and * keys, and then press the ENT or key.

00001 >> _ To return to the SET COMMUNICATION menu, press the C key.

SET ID 00001 >> 65535_

Selecting the "2:BHT-Ir Protocol" on the PROTOCOL TYPE screen calls up the screen shown at left. Enter the ID number of the BHT-7000 by using the numerical keys, and then press the ENT key. If you do not need to modify the current setting, press the ENT key only.

NOTE

An ID number should be five-digit decimal character string. The entry range is from 00001 to 65535. If the entry value is less than five digits, the ENT key will be deactivated.

If you make a wrong entry, press the BS key to delete it and then enter the correct data. To return to the SET COMMUNICATION menu, press the C key. * For BHT-7000s having a 26-key pad, use F5 , F6 , F7 and F8 keys instead of , and keys, respectively

58

,

,

Page 75

Chapter 2. Getting Started the BHT-7000 and System Mode

[4.6]

Defining the functions of the shift key and magic keys SET KEY 1:SHIFT KEY 2:M1 KEY 3:M2 KEY 4:M3 KEY 5:M4 KEY

Selecting the "6:KEY" on the SET SYSTEM menu calls up the screen shown at left. Highlighted is the current setting. 1 SHIFT KEY:

Switches to the shift key definition screen.

2 M1 KEY:

Switches to the M1 key definition screen.

3 M2 KEY:

Switches to the M2 key definition screen.

4 M3 KEY:

Switches to the M3 (left-hand trigger switch) key definition screen.

5 M4 KEY:

Switches to the M4 key (righthand trigger switch) definition screen.

Select a desired screen by using the numerical keys or * and * keys, and then press the ENT key. To return to the SET SYSTEM menu, press the C key.

Defining the function of the shift key SET SHIFT KEY

Selecting the "1:SHIFT KEY" on the SET KEY menu calls up the screen shown at left.

1:Nonlock 2:Onetime

Highlighted is the current setting. 1 Nonlock:

Shifts the keypad only when the SF key is held down.

2 Onetime:

Shifts only one key pressed immediately after the SF key is pressed. (The following keys will not be shifted.)

Select a desired setting by using the numerical keys or * and * keys, and then press the ENT key. The screen returns to the SET KEY menu. * For BHT-7000s having a 26-key pad, use F5 , F6 , F7 and F8 keys instead of , and keys, respectively

59

,

,

Page 76

Defining the function of M1 , M2 , M3 (left-hand trigger switch), or M4 (right-hand trigger switch) key SET M3 KEY 1:None 2:Trigger Switch 3:Shift Key 4:Enter Key 5:Backlight Key

Selecting the "2:M1 KEY," "3:M2 KEY," "4:M3 KEY" or "5:M4 KEY" on the SET KEY menu calls up the screen as shown at left. (This example appears when the "4:M3 KEY.") Highlighted is the current setting. The M1 , M2 , M3 or M4 key can function as listed below. 1 None:

The key entry will be ignored.

2 Trigger Switch:

As the trigger switch.

3 Shift Key:

As the SF key.

4 Enter Key:

As the ENT key.

5 Backlight Key:

As the backlight function on/off key.

Select a desired setting by using the numerical keys or * and * keys, and then press the ENT key. The screen returns to the SET KEY menu.

Magic keys The M3 and M4 keys are assigned the trigger switch function by default. You can make them function as the SF key, ENT key, or backlight function on/off key. If you define the M1 key as the backlight function on/off key, pressing the M1 key activates or deactivates the backlight function. In user programs, a string data also can be assigned to these magic keys.

NOTE

The backlight function on/off key can be assigned only to any one of M1 through M4 keys. The key defined more recently will act as the backlight function on/off key and one defined earlier will be ignored. That is, if you define the M1 and M2 keys as the backlight function on/off key in this order, the M2 key will work as the backlight function on/off key and the M1 key's entry will be ignored.

* For BHT-7000s having a 26-key pad, use F5 , F6 , F7 and F8 keys instead of , and keys, respectively

60

,

,

Page 77

Chapter 2. Getting Started the BHT-7000 and System Mode

[4.7]

Setting the resume function SET RESUME

1:ON

2:OFF

Selecting "7: RESUME" on the SET SYSTEM menu calls up the screen shown at left. Highlighted is the current setting. 1 ON

: Activates the resume function which resumes whatever display was shown before the power was turned off, when the BHT-7000 is powered up.

2 OFF

: Deactivates the resume function.

Select a desired item by using the numerical keys or * and * keys, and then press the ENT key. To return to the SET SYSTEM menu, press the C key.

* For BHT-7000s having a 26-key pad, use F5 , F6 , F7 and F8 keys instead of , and keys, respectively

61

,

,

Page 78

[ 5 ] Testing TEST

Selecting "5: TEST" on the SYSTEM MENU calls up the screen shown at left.

1:BARCODE 2:MEMORY 3:BEEPER 4:AGING 5:LCD 6:FILE 7:COMMUNICATION 8:KEY & VIBRATION

1 BARCODE : Selects the bar-code reading test. 2 MEMORY : Selects the RAM read/write test. 3 BEEPER

: Selects the beeper scale test.

4 AGING

: Selects the aging test.

5 LCD

: Selects the LCD and indicator LED tests.

6 FILE

: Selects the file checksum test.

7 COMMUNICATION : Selects the communications test. 8 KEY & VIBRATION : Selects the key entry, beeper and vibrator tests. Select a desired setting by using the numerical keys or * and * keys, and then press the ENT key. The selected test will start. Highlighted is the currently selected item. To return to the SYSTEM MENU, press the C key.

If an error occurs in any of the above tests, contact your nearest dealer.

* For BHT-7000s having a 26-key pad, use F5 , F6 , F7 and F8 keys instead of , and keys, respectively

62

,

,

Page 79

Chapter 2. Getting Started the BHT-7000 and System Mode

[5.1]

Bar-code reading test

TEST BARCODE

Selecting "1: BARCODE" on the TEST menu calls up the screen shown at left. Actually read bar codes with the BHT-7000 and check the read data displayed on the LCD.

⇓ Bar-code type Number of digits of the bar code

Upon completion of bar-code reading, the BHT7000 beeps, turns on the indicator LED in green, and displays the read data together with the barcode type and the number of data digits.

TEST BARCODE A 13 4999999999999

Up to 64-digit data can be shown and the excess will be discarded. To return to the TEST menu, press the C key.

Data

Listed below is a table showing the relationship between the bar-code types and the identifier letters to be displayed on the LCD.

Bar-code Type

ID Letters

EAN-13, UPC-A

A

EAN-8

B

UPC-E

C

Standard 2 of 5 (STF)

H

Interleaved 2 of 5 (ITF)*

I

CODABAR

N

CODE39

M

CODE93

L

CODE128

K

EAN-128

W

* The BHT-7000 can read only those ITF bar codes having 4 digits or more in length.

63

Page 80

[5.2]

Memory test TEST MEMORY

** Testing ** XXXXX/YYYYY

Selecting "2:MEMORY" on the TEST menu calls up the screen shown at left, and then starts writing and reading onto/from all areas of the RAM as well as checking the address. XXXXX: Tested RAM capacity (unit: kilobytes) YYYYY:

TEST MEMORY ** Test NG ** XXXXX/YYYYY Address : ZZZZZZZZ Write : AAAAAAAA Read : BBBBBBBB

Total RAM capacity (unit: kilobytes)

If any error is detected, the BHT-7000 beeps three times, shows the message as shown at left, and terminates the test. Where, ZZZZZZZZ:

Address where an error has occurred.

AAAAAAAA: Data to write. BBBBBBBB: Data read out from the RAM. To return to the TEST menu, press the C key.

TEST MEMORY ** Test OK ** YYYYY/YYYYY

Upon normal completion of the RAM test, the BHT7000 beeps once, shows the message as shown at left, and returns to the TEST menu.

64

Page 81

Chapter 2. Getting Started the BHT-7000 and System Mode

[5.3]

Beeper scale test TEST BEEPER

Selecting "3:BEEPER" on the TEST menu calls up the screen shown at left and makes the beeper sound at three octaves listed below. Upon completion of this test, the BHT-7000 automatically returns to the TEST menu. To stop this test while in progress, turn the power off and on. Scale

[5.4]

Frequency (Hz)

do

523

1046

2093

4186 re

587

1174

2349

- mi

659

1318

2637

- fa

698

1396

2793

- sol

783

1567

3135

- la

880

1760

3520

- ti

987

1975

3951

-

Aging test TEST AGING

DATE TIME

99/03/01 15:30:00

Selecting "4:AGING" on the TEST menu proceeds to the aging test while showing the current date and time on the LCD. (This test is intended for personnel which check the BHT-7000 in the factory.)

Once this test is selected, the automatic powering-off function becomes disabled. Be sure to turn the power off or press the C key to return to the TEST menu.

65

Page 82

[5.5]

LCD and indicator LED tests Selecting "5:LCD" on the TEST menu calls up the test pattern shown at left on the LCD and turns on the indicator LED in green. Each time the ENT key is pressed, the screen shifts to the next test pattern. To return to the previous screen, press the BS key.

BS key

⇑

⇓

ENT key

To stop this test while in progress, press the C key. As shown at left, everything disappear and the indicator LED lights in red.

BS key

⇑

⇓

ENT key

The checker pattern shown at left appears and the indicator LED goes off.

BS key

⇑

⇓

ENT key

The checker pattern is reversed.

BS key

⇑

⇓

ENT key

66