Bar Code Handy Terminal BHT-7000 User's Manual: Chapter 2 Getting Started the BHT-7000 and System Mode, pages 23 to 32
Pages 23 to 32 of 175, from Bar Code Handy Terminal BHT-7000 User's Manual
The original document is the PDF (934 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Denso BHT-7000
Page 23
Chapter 2. Getting Started the BHT-7000 and System Mode
Chapter 2 Getting Started the BHT-7000 and System Mode This chapter summarizes the BHT-7000 system configuration and describes the operation including preparation and System Mode (which is required for the efficient use of application programs). 2.1
BHT-7000 System Configuration ........................................................................
8
2.2
Infrared Communications ...................................................................................
13
2.3
Components and Functions ................................................................................
15
2.4
Preparation ...........................................................................................................
18
2.4.1
Setting-up 1: Loading the Battery Cartridge ..............................................
18
2.4.2
Setting-up 2: Setting the Calendar Clock ...................................................
22
2.4.3
Adjusting the LCD Contrast & Beeper Volume, Switching the Beeper & Vibrator, and Checking the Battery Voltage Level .................................
24
[ 1 ] Adjusting the LCD Contrast & Beeper Volume and Switching the Beeper & Vibrator ........................................................................................
24
[ 2 ] Checking the Battery Voltage Level .......................................................... 2.4.4
26
Battery Replacement Notes ..........................................................................
27
2.5
Initializing the BHT-7000 System .......................................................................
29
2.6
Operating in System Mode .................................................................................
33
2.6.1
Starting System Mode ...................................................................................
33
2.6.2
Operating in System Mode ...........................................................................
37
[ 1 ] Calling up the desired set screen ..............................................................
37
[ 2 ] Selecting a desired setting .........................................................................
38
2.6.3
Detailed Description of the Functions in System Mode ............................
39
[ 1 ] Program Execution ......................................................................................
39
[ 2 ] Downloading ................................................................................................
40
[ 3 ] Uploading .....................................................................................................
44
[ 4 ] System Environment Setting .....................................................................
47
[ 5 ] Testing ..........................................................................................................
62
[ 6 ] System Information ....................................................................................
74
[ 7 ] Deleting Files ...............................................................................................
75
[ 8 ] Downloading/Uploading the BHT System Parameter File .....................
76
[ 9 ] Setting the Remote Wakeup ......................................................................
80
[10]
81
Downloading/Uploading the System Message File ................................
7
Page 24
2.1 BHT-7000 System Configuration The BHT-7000 barcode data collection system requires the following hardware as well as the BHT-7000 Bar Code Handy Terminal (which reads bar codes and accepts keypad entry) as illustrated below: • Host computer:
Allows you to edit, manage and download programs and data, as well as downloading extension programs.
For host computers without IrDA interface ports, the optional CU-7000 optical communications unit and RS-232C interface cable are available. • CU-7000 (option):
Exchanges programs and data with the BHT-7000 optically and with the host computer via the RS-232C interface.
• RS-232C interface cable: Connects the CU-7000 and the host computer. (option) Optional software includes the BHT-BASIC Extension Library, BHT-BASIC Compiler, IrTransfer Utility C, Ir-Transfer Utility E, and Transfer Utility.
System Configuration
Host Computer BHT-7000 Optical Communications RS-232C Interface
Optical Communications RS-232C Interface (option)
CU-7000 (option)
BHT-BASIC Compiler (option) Ir-Transfer Utility C (option) Ir-Transfer Utility E (option) Transfer Utility (option)
■ Host Computer Models: PC/AT, PS/2 Optional application programs and OSes OS Applications
BHT-BASIC Compiler Ir-Transfer Utility C Ir-Transfer Utility E
MS-DOS
Windows version 3.1
Windows 95/98
WindowsNT 3.51/4.0
BHT-BASIC3.0 (MS-DOS–based)
BHT-BASIC3.0 (Windows3.1-based)
BHT-BASIC3.5
BHT-BASIC3.5
MS-DOS–based, Windows95-/98-/ NT-based Windows95-/NTbased Windows95-/98-/ NT-based
Windows95-/98-/ NT-based Windows95-/NTbased Windows95-/98-/ NT-based, Transfer Utility MS-DOS–based, Windows3.1–based
8
Page 25
Chapter 2. Getting Started the BHT-7000 and System Mode
■ CU-7000 and RS-232C Interface Cable (option) The CU-7000 is an IrDA-compliant communications unit which is required when your host computer is not equipped with an IrDA interface port. The CU-7000 exchanges data and programs with the BHT-7000 optically, and with the host computer via the RS-232C interface cable. You may directly connect two BHT-7000s with each other by using a commercially available metal cable having 3-pole mini stereo plugs (as a direct-connect interface cable). You also connect the BHT-7000 directly with the host computer or with the modem by using the direct-connect interface cable compatible with the target equipment. (NOTE: The direct-connect interface port of the BHT-7000 is not designed to stand frequent connecting/disconnecting. You are, therefore, recommended to use the CU-7000 where you expect to do a lot of connecting and disconnecting of the BHT7000 to/from a host computer.)
■ BHT-BASIC Compiler (option) This Compiler compiles a source program written in BHT-BASIC by an editor of the host computer running the MS-DOS, into the object program (user program) which can be used in the BHT-7000. The compiled and linked program file is named "XXX.PD3." (XXX: File name you can set arbitrarily under the MS-DOS rules) You should download it to the BHT-7000 by using Ir-Transfer Utility C/Ir-Transfer Utility E/Transfer Utility.
■ Ir-Transfer Utility C (option) Running on the host computer, this utility transfers files between the BHT-7000 and the host computer. For its file transfer control procedure, the utility uses the BHT-Ir protocol. (For the details about the BHT-Ir protocol, refer to Chapter 3, Subsection 3.3.2.) To transfer files under any of the following conditions, use Ir-Transfer Utility C: -
At transmission speeds of 115200 or 57600 bps (This may be impossible depending upon the host computer type.)
-
Via the CU-7000
-
When transferring via the direct-connect interface of the BHT-7000
9
Page 26
■ Ir-Transfer Utility E (option) Running on the host computer, this utility transfers files between the BHT-7000 and the host computer. For its file transfer control procedure, the utility uses the BHT-Ir protocol. (For the details about the BHT-Ir protocol, refer to Chapter 3, Subsection 3.3.2.) To transfer files under any of the following conditions, use Ir-Transfer Utility E: -
Via an external IR transceiver
-
Via an IR port integrated in a computer
■ Transfer Utility (option) Running on the host computer, this utility transfers files between the BHT-7000 and the host computer. It uses the BHT-protocol as a file transfer control procedure. (For the details about the BHT-protocol, refer to Chapter 3, Subsection 3.3.1.) To transfer files under any of the following conditions, use Transfer Utility: -
When the BHT-7000 is placed on the CU-7000
-
Via the direct-connect interface of the BHT-7000
10
Page 27
Chapter 2. Getting Started the BHT-7000 and System Mode
Software Structure System Program and JIS Level 1 & Level 2 fonts are resident in the system area and user area, respectively. To use extension programs and user programs, you should download the program files into the user area.
System Programs
JIS Level 1 & Level 2 font files
User programs
Program files
User Area
⇔
System Area
Data files
Host Computer
■ System Programs The system programs include the following three sets of programs:
Drivers Drivers is a set of programs that directly controls the BHT-7000 hardware. It may be called up by the BHT-BASIC Interpreter or System Mode.
BHT-BASIC Interpreter The interpreter interprets and executes instructions in user programs written in BHTBASIC.
11
Page 28
System Mode System Mode is a system program exclusively designed for the effective use of user programs in the BHT-7000. It sets up the execution environments for those programs; e.g., it prepares downloading/uploading conditions, sets the calendar clock, and tests the BHT-7000 components including the LCD, beeper, and keypad. Shown below is the System Mode menu (SYSTEM MENU).
SYSTEM MENU 1:EXECUTE PROGRAM 2:DOWNLOAD 3:UPLOAD 4:SET SYSTEM 5:TEST 6:VERSION
■ JIS Level 1 and Level 2 Font Files These files contain font data required for displaying Kanji characters on the LCD. The BHT-7000 can display the Kanji characters not only in the conventional standardsize font (16 dots wide by 16 dots high) but also in the small-size font (12 dots wide by 12 dots high) in application programs. It can also display the double-width Kanji characters of those 16-dot and 12-dot fonts in application programs.
TIP
If you do not need to display Kanji characters, you may delete these JIS font files. After deletion, the memory area which was occupied by these files can be used as a user area. For the deleting procedure, refer to Section 2.5, “Initializing the BHT7000 System” or Subsection 2.6.3, “[ 7 ] Deleting Files.” The names of the JIS font files are: FNT16J1.FN3 FNT16J2.FN3 FNT12J1.FN3 FNT12J2.FN3
(JIS Level 1 font, 16-dot) (JIS Level 2 font, 16-dot) (JIS Level 1 font, 12-dot) (JIS Level 2 font, 12-dot)
■ User Programs You can develop application programs to meet individual job requirements by using the BHT-BASIC Compiler. To download those user programs to the BHT-7000, use IrTranser Utility C/Ir-Transfer Utility E/Transfer Utility.
12
Page 29
Chapter 2. Getting Started the BHT-7000 and System Mode
2.2 Infrared Communications The BHT-7000 has an integrated infrared (IR) communications device which enables wireless transfer of programs and data between the BHT-7000 and the host computer and between the BHT-7000s, instead of the conventional wire transfer. Host computer
BHT-7000
BHT-7000
The IR communications device features the following: •
Wireless communications
•
Small and lightweight design
•
High transmission speed
•
Freedom from the codes/regulations and licenses which differ from country to country, unlike radio devices
The BHT-7000's IR communications device is IrDA-compliant. IrDA stands for Infrared Data Association, which has defined hardware (IrDA Serial Infrared Physical Layer Link) and communications protocols for IR communications.
13
Page 30
The BHT-7000's physical layer complies with the IrDA1.0, with a maximum transfer distance of 0.8 m and maximum transmission rate of 115.2 kbits per second. The BHT-7000 adopts the exclusive BHT-Ir protocol which allows you to develop user programs for IR communications in BHT-BASIC, as can be done with conventional wire communications.
User programs
BHT-BASIC
BHT-Ir protocol
Physical layer (IrDA1.0)
14
Page 31
Chapter 2. Getting Started the BHT-7000 and System Mode
2.3 Components and Functions Indicator LED Illuminates in green when the BHT has successfully read the bar codes. Trigger switch (M4 key)* Press this switch to start bar-code reading. Alphanumeric keys** Liquid crystal display (LCD) Shows the characters and graphic patterns. Trigger switch (M3 key)* Press this switch to start bar-code reading. Optical interface port Used to exchange data/programs with the host computer via its integrated IR port or via the optical communication unit CU-7000.
Hand strap Be sure to put your hand through this strap to prevent you from dropping the BHT accidentally. Connector cover Inside this cover is the directconnect interface port.
Release button Press this button to remove the battery cartridge. Rating plate Caution label
Rechargeable battery cartridge or dry battery cartridge Main power source of the BHT.
Bar-code reading window (through which a laser beam will be emitted)
* The tirgger switch function is assigned to both of the M3 and M4 keys by default. ** The keypad is available in two types: 32-key pad and 26-key pad.
15
Page 32
The functions of the keys may be set by user programs. Shown below is a set of sample functions. 32-key pad Status Indicators Battery voltage level Shows the current battery voltage level. If the voltage level is high, three bars appear; if low, a single bar appears. The displayed battery level shows the terminal voltage of the battery cartridge, not how much power is left.
Keypad shift state SF
Shows a bar when the keypad is shifted.
Alphabet input ALP Shows a bar when the alphanumeric entry system is selected.
ALP (Alphabet) key Switches the keypad to alphabet entry. C (Clear) key Clears the last inputted data or returns to the original screen. If pressed together with SF key, this C key works as a backspace key.
SF (Shift) key Used in combination with numerical keys for special input procedures.
PW (Power) key Turns the BHT on or off. M1/M2 (Magic) keys Used as any of the ENT key, trigger switch, SF key, and backlight function on/off key depending upon definition in System Mode or in user programs. These keys can be also assigned string data.
Cursor keys Used to move up to the preceding line, down to the next line, to the preceding character, and to the next character. Numerical keys Used for numerical input.
ENT (Enter) key Finalizes the inputted data or operations, and starts the corresponding processing.
Function keys Used for choosing functions.
16