Bar Code Handy Terminal BHT-7000 User's Manual: Chapter 1 Quick Guide

Pages 17 to 22 of 175, from Bar Code Handy Terminal BHT-7000 User's Manual

The original document is the PDF (934 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Denso BHT-7000

Page 17

Chapter 1. Quick Guide

Chapter 1 Quick Guide

This chapter describes the basic operating method of the BHT-7000 and the related notes.

1.1

Reading Bar Codes ...............................................................................

2

1.2

Setting and Using the Hand Strap ....................................................

3

1.3

Setting the Backlight ............................................................................

4

1.4

Using the Keypad .................................................................................

5

1.5

Communicating via the Optical Interface .........................................

6

1

Page 18

1.1 Reading Bar Codes Turn on the BHT power, bring the bar-code reading window to the bar code to be scanned, and press the trigger switch. The BHT emits a laser light to indicate the scanning range and turns on the illumination LED to scan the bar code. Keep the BHT in a position where the bar code lies within the scanning range indicated by the laser light (marker). When the BHT has read the bar code successfully, the indicator LED will illuminate in green. Bar code scanning range indicated by the laser light

Indicator LED (Illuminates in green when the BHT has read the bar code successfully.) Trigger switch (M4 key)*

Max. 40 cm (15.7")** Trigger switch (M3 key)* * The trigger switch function is assigned to both of the M3 and M4 keys by default.)

PW key

• If the BHT fails to read due to specular effects or other factors, change the scanning angle of the reading window or the distance from codes as shown at right, and try it again. (Specular effects occur when the reflection of the light from the bar code becomes excessively strong. This can easily happen when the reflecting surface is polished or covered with vinyl.) • The laser light indicates the scanning range as a guide. The indicated scanning range will deviate a little bit from the actual one. Keep the BHT so that the laser light comes to almost the center of the bar code height. • The BHT can read bar codes at a maximum distance of 40 cm (15.7")** from the bar-code reading window. (**For details about the scanning conditions, refer to the Appendix A.)

NOTE

• Before reading bar codes, clean those labels if stained. • Avoid using the BHT in direct sunlight. The BHT might fail to read correctly. • To read bar codes on curved surfaces, apply the BHT to the target bar code so that the code comes to the center of the scanning range indicated by the laser beam. • When you pull the bar-code reading window away from the bar codes, the actual scanning range will become narrower than the range covered by the laser beam.

TIP

• The light intensity of the laser light or illumination LED will vary depending upon the scanning conditions and variation of their elements.

2

Page 19

Chapter 1. Quick Guide

1.2 Setting and Using the Hand Strap ■ Setting the hand strap

■ Using the hand strap Put your hand through the hand strap and hold the BHT as shown below. This will prevent you from dropping the BHT accidentally.

Hand strap

3

Page 20

1.3 Setting the Backlight Pressing the M1 key while holding down SF (Shift) key activates or deactivates the backlight function.

Backlight OFF (The backlight function is OFF when you power on the BHT.)

Press M1 while holding down SF .

SF M1 Backlight ON Press M1 while holding down SF .

If no key is pressed for at least 3 seconds.

Press any key (except for the simultaneous depression of M1 and SF ).

(26-key pad)

NOTE

Backlight OFF (The backlight function is kept ON.)

Press M1 while holding down SF .

In user programs, you can select the key to be used for activating or deactivating the backlight function (instead of the initial setting: combination of SF and M1 ), as well as modifying the ON-duration of the backlight before the automatic turning-off.

4

Page 21

Chapter 1. Quick Guide

1.4 Using the Keypad ■ Entering Numerical Data To enter numerical data, e.g., the quantity of goods, use the ten numerical keys and the ENT key. For example, to enter the number "120," press the 1 , 2 and 0 keys and then press the ENT key. 26-key pad: If you key in any wrong value, press the C key or BS key and then enter the correct one. 32-key pad: If you key in any wrong value, press the C key or SF + C keys and then enter the correct one.

■ Selecting Tasks If the LCD shows the selection items (xxx) prefixed by numerals (e.g., 1: xxx, 2: xxx), use the numerical keys to select a desired item and press the ENT key to execute. If a YES/NO screen (e.g., 1: YES, 2: NO) appears, press the 1 key for YES response and 2 key for NO response.

■ Entering Alphabetic Characters The BHT-7000 supports the alphabet input function which allows you to enter alphabetic characters, space, and symbols from the keypad during execution of a user program. For the alphabet input procedure, refer to the "BHT-BASIC Programmer's Manual."

5

Page 22

1.5 Communicating via the Optical Interface ■ Optical Communications with the BHT-7000 The BHT-7000 communicates using an IR beam, so make sure that there is no obstruction in the light path between the BHT-7000 and any target stations. In the IrDA communications mode, you need to keep the BHT-7000 and any target stations within the effective light emission range, usually 10 to 80 cm (3.94 to 31.50'').

■ Communicating with the CU-7000 The optional CU-7000 is an IrDA-compliant communications unit. For optical communications, put the BHT-7000 directly on the CU-7000 as shown below.

■ Communicating with other IrDA-compliant equipment You can also have the BHT-7000 communicate with other IrDA-compliant equipment just by aligning their IR ports with each other. The effective IR range and IR port angle may differ depending upon the target equipment, so observe the instructions given in manuals furnished with such equipment.

If transfer using the BHT-7000 fails, bring it closer to the target station or change the IR port angle, and try again.

NOTE

Communications failures might be caused by highly intensive light emitted from ceiling (inverter-driven fluorescent) lamps or direct sunlight. Take care to prevent such interference light from coming into the optical interface ports of the BHT7000 and IrDA-compliant equipment, including the CU-7000.

NOTE

Do not use any TV remote control in the vicinity of the IR communications system. Doing so may interfere with the communications.

6