Page 151

Appendices

■ Abnormal termination of phase 1 (Abort of phase 1) If the sending station receives no ACK from the receiving station after sending an ENQ 10 times in succession, it sends an EOT to the receiving station after three seconds from the 10th ENQ to terminate the message transmission abnormally.

Sending station

Receiving station

ENQ(1) 3 seconds

ENQ(2) 3 seconds

ENQ(3)

ENQ(10) 3 seconds

EOT Abnormal termination

TIP

The receiving station's default timeout is 30 seconds. You may modify the timeout length on the SET PROTOCOL screen in System Mode (pp. 54 and 56) or by using the XFILE statement (refer to the "BHT-BASIC Programmer's Manual").

135

Page 152

Phase 2: Data Transmission ■ Normal phase 2 The sending station first sends a transmission block containing the heading text. Each time the sending station receives an ACK from the receiving station, it sends a transmission block containing the data texts as shown below. Upon receipt of an ACK in response to the last transmission block (data text n), the sending station shifts to phase 3. If a transmission message contains no data text, the sending station transmits the heading text only.

Sending station

Receiving station Heading text

ACK

Data text 1

ACK

Data text n-1

ACK

Data text n

ACK

To phase 3.

136

Page 153

Appendices

■ Phase 2 with NAK If the sending station receives a NAK from the receiving station in response to a transmission block containing text data m, it sends that transmission block again immediately as shown below. If the sending station receives an ACK before receiving a NAK 10 times in succession, it continues the subsequent message transmission.

Sending station

Data text m

Receiving station

NAK

Data text m NAK

Data text m ACK

Data text m+1

If the sending station receives a NAK 10 times in succession or it fails to send a same transmission block, it shifts to phase 3 to terminate the message transmission abnormally. Even if the phase 3 terminates normally, the transmission results in an abnormal end. Sending station

Data text m (1) NAK

Data text m (2) NAK

Data text m (10) NAK

Occurrence of an error To phase 3.

137

Receiving station

Page 154

■ Phase 2 with EOT If the sending station receives an EOT anytime during phase 2, it shifts to phase 3 to terminate the message transmission abnormally. Even if the phase 3 terminates normally, the transmission results in an abnormal end.

Receiving station

Sending station

EOT

Occurrence of an error To phase 3.

■ Phase 2 with iterated ENQ transmission due to no response or invalid response If the sending station receives no response or any invalid response from the receiving station in response to a transmission block sent, it iterates sending of an ENQ at three-second intervals up to nine times. If the sending station receives an ACK before sending an ENQ nine times, it continues the subsequent message transmission.

Sending station

Data text m

3 seconds

ENQ 3 seconds

ENQ ACK Data text m+1

138

Receiving station

Page 155

Appendices

■ Abnormal termination of phase 2 (Abort of phase 2) If the sending station receives no ACK from the receiving station after sending an ENQ nine times in succession, it sends an EOT to the receiving station after 3 seconds from the 9th ENQ to terminate this transmission sequence abnormally.

Sending station

Receiving station

3 seconds

ENQ (1) 3 seconds

ENQ (2)

ENQ (9) 3 seconds

EOT Abnormal termination

Phase 3: Release of Data Link ■ Normal phase 3 The sending station transmits an EOT to the receiving station. Upon receipt of an ACK from the receiving station, the sending station terminates the message transmission normally and releases the data link.

Sending station

EOT

ACK

Normal termination

139

Receiving station

Page 156

■ Phase 3 with iterated EOT transmission due to no response or invalid response If the sending station receives no response or any invalid response from the receiving station in response to an EOT sent, it iterates sending of an EOT at threesecond intervals up to ten times. If the sending station receives an ACK before sending an EOT ten times, it terminates the message transmission normally and releases the data link.

Sending station 3 seconds

EOT

Receiving station

EOT 3 seconds

EOT

ACK

Normal termination

■ Abnormal termination of phase 3 If the sending station receives no ACK from the receiving station within three seconds from the 10th EOT, it terminates the message transmission abnormally and releases the data link.

Sending station 3 seconds

EOT (1) EOT (2)

3 seconds

EOT (3)

3 seconds or more

EOT (10)

Abnormal termination

140

Receiving station

Page 157

Appendices

[ 2 ] Aborting Data Transmission Pressing the C key aborts data transmission. If the C key is pressed during downloading, the BHT-7000 transmits an EOT and aborts the file transmission. If it is pressed during uploading, the BHT-7000 transmits the current transmission block followed by EOT and then aborts the file transmission.

141

Page 158

[ 3 ] BCC for Horizontal Parity Checking To check whether data has been transmitted accurately, the BHT-7000 supports horizontal parity checking for every transmission block. In horizontal parity checking, a horizontal parity byte so called BCC (Block Check Character) is suffixed to an ETX of every transmission block. In the BHT-protocol, every parity bit of BCC is set so that all set bits at the same bit level (including a parity bit) in the characters contained in the transmission block have an even number by binary addition, excluding SOH, STX, and functions SOH$ and STX$. (For details about SOH$ and STX$ which are protocol functions unique to BHT-BASIC, refer to the "BHT-BASIC Programmer's Manual.")

(Vertical parity)

b7 b0

Character [ For 8-bit data ]

Horizontal parity byte (BCC)

Shown below is a data text block indicating the bits to be added for horizontal parity checking.

S T X

Serial number

Data text

To be added for horizontal parity checking

142

E T X

B C C

Page 159

Appendices

B.2

BHT-Ir protocol

[ 1 ] Transmission Control Sequences Shown below is a typical message transmission sequence supported by the BHT-Ir protocol. This sequence example does not include transmission errors or negative responses.

Sending Station

Establishment of Data Link (Phase 1)

Receiving Station

DLE ENQ and IDm* DLE ACK and IDs**

D S L • O E H

I

Heading text D

D E L • T E X

C R C

DLE ACK and IDs D S L • T E X

I D

Serial number

Data text 1

D E L • T E X

C R C

DLE ACK and IDs

Data Transmission (Phase 2)

D S L • T E X

I D

Serial number

Data text n-1

D E L • T E X

C R C

DLE ACK and IDs D S L • T E X

I D

Serial number

Data text n

D E L • T E X

C R C

DLE ACK and IDs Release of Data Link (Phase 3)

DLE EOT and IDs DLE ACK and IDs

*IDm: ID of sending station **IDs: ID of receiving station

143

Page 160

Data transmission may accidentally involve various types of errors. The BHT-Ir protocol is designed to recover from those errors as frequently as possible. What follows is the BHT-Ir protocol for phases 1 through 3.

Phase 1: Establishment of Data Link ■ Normal phase 1 The sending station transmits a sequence of DLE ENQ and IDm (sending station's ID) to the receiving station. Upon receipt of a sequence of DLE ACK and IDs (receiving station's ID) from the receiving station, the sending station shifts to phase 2.

DLE ENQ and IDm

Sending station

Receiving station

DLE ACK and IDs

To phase 2.

■ Phase 1 with iterated transmission of DLE ENQ and IDm due to no response or invalid response If the sending station receives no response or any invalid response from the receiving station in response to the sent sequence of DLE ENQ and IDm, it iterates sending of the sequence at 0.5-second intervals up to 60 times. If the sending station receives a sequence of DLE ACK and IDs before sending the sequence of DLE ENQ and IDm 60 times, it shifts to phase 2. Sending station 0.5 second 0.5 second

DLE ENQ and IDm

Receiving station

DLE ENQ and IDm DLE ENQ and IDm

DLE ACK and IDs

To phase 2.

TIP

You may modify the number of iterations of a sequence of DLE ENQ and IDm for the sending station. The default is 60 times at 0.5-second intervals. For details, refer to the SET PROTOCOL screen in System Mode (pp. 54 and 56) and the XFILE statement given in "BHT-BASIC Programmer's Manual." 144