Page 141

Appendices

Appendix A. Specifications .......................................................................... 126 A.1 BHT-7000 .............................................................................................. 126 [ 1 ] Product Specifications ................................................................. 126 [ 2 ] Bar Code Specifications ............................................................... 128 [ 3 ] Interface Specifications ............................................................... 130 A.2 CU-7000 ................................................................................................. 131 [ 1 ] Product Specifications ................................................................. 131 [ 2 ] Charging Requirements (CU-7001) ............................................. 131 [ 3 ] Interface Specifications ............................................................... 132 Appendix B. Communications Protocol Details ......................................... 133 B.1 BHT-protocol ......................................................................................... 133 [ 1 ] Transmission Control Sequences ............................................... 133 [ 2 ] Aborting Data Transmission ....................................................... 141 [ 3 ] BCC for Horizontal Parity Checking ............................................ 142 B.2 BHT-Ir protocol ..................................................................................... 143 [ 1 ] Transmission Control Sequences ............................................... 143 [ 2 ] Aborting Data Transmission ....................................................... 152 [ 3 ] CRC ................................................................................................. 153 [ 4 ] ID ..................................................................................................... 153 Appendix C. A Typical Basic Operation ...................................................... 154

Appendices

125

Page 142

Appendix A. Specifications A.1

BHT-7000

[ 1 ] Product Specifications Power Source

Main power

• Rechargeable lithium-ion battery cartridge (3.6 VDC) or • Dry battery cartridge (two alkaline manganese batteries LR6s)

Dimensions (W) x (L) x (H)

70 x 195 x 51 mm (2.8 x 7.7 x 2.0 inches)

Weight

Approx. 210 g (Approx. 7.4 oz.) including battery cartridge

Operating Ambient Temperature

-5˚C to 50˚C (23˚F to 122˚F)

Operating Humidity

20% to 80% (with no dew condensation)

Ambient Illuminance

500 to 3000 x. (Depth of field: 80 mm, PCS value: 0.9 min., Reflection intensity: 85% min. for white and 5% max. for black, Narrow bar width: 0.127 mm min.) 20 to 10000 x. (Depth of field: 430 mm, ITF: 1.0 magnification, PCS value: 0.9 min., Reflection intensity: 85% min. for white and 5% max. for black)

Controller

CPU:

32-bit RISC

RAM:

512KB

Flash memory:

4MB

Keypad

26-key pad

32-key pad

Magic keys

4

4

Function keys

8

10

Numerical keys and others

16

20

126

Page 143

Appendices

Display

Type:

Dot-matrix, FSTN liquid crystal display (LCD) with backlight

Formation:

Character display 128 dots wide by 64 dots high Status display 128 dots wide by 1 dot high

Screen mode Font size

Chars x Lines

Dots (W x H)

21 x 8 21 x 10

6x8 6x6

Single-byte ANK* mode

Standard-size Small-size

Two-byte Kanji mode

16-dot font

Full-width Half-width

8x4 16 x 4

16 x 16 8 x 16

16-dot font (Double-width)

Full-width Half-width

4x4 8x4

32 x 16 16 x 16

12-dot font

Full-width Half-width

10 x 5 20 x 5

12 x 12 6 x 12

12-dot font (Double-width)

Full-width Half-width

5x5 10 x 5

24 x 12 12 x 12

*ANK: Alphanumerics and Katakana

Calendar Clock

Year, month, day, hour, minute, and second • Year

Indicator LED

Two digits (with auto-correction on February 29 for year 1901 to 2099)

Colors: Red and green

127

Page 144

[ 2 ] Bar Code Specifications (1) Available Bar Code Types Bar code type

Bar dimensions

Readable magnification

Universal product codes EAN-13 EAN-8 UPC-A UPC-E EAN-13 with supplemental codes

0.26 mm (10.24 mils)

0.8 magnification min.

EAN-8 with supplemental codes UPC-A with supplemental codes UPC-E with supplemental codes 2-digit add-on 5-digit add-on Interleaved 2 of 5 (ITF) Standard 2 of 5 (STF) CODABAR

0.125 mm min. (4.9 mils min.) PCS value ≥ 0.75 Reflection intensity difference between white and black bars ≥ 0.4 0.15 mm min. (5.91 mils min.) (PCS value ≥ 0.45)

CODE39

CODE93

0.15 mm min. (5.91 mils min.) (PCS value ≥ 0.45)

CODE128

(2) Optical Properties Required for Bar Code Labels White bars: Reflection intensity

45% min.

Black bars:

25% max. 0.45 min.

Reflection intensity PCS value

128

Page 145

Appendices

(3) Bar Code Label Size Recommended width: 10 mm min. (0.39 inch min.) Length:

Depth of field (Distance from bar codes to the bar-code reading window) 400 mm (15.75 inches)

Length of labels (including margins) 460 mm max. (18.11 inches max.) (Minimum narrow bar width: 1.0 mm min.)*4

Length

Width

(4) Thickness of Bars and Depth of Field Minimum narrow bar width 0.125 mm 0.15 mm 0.33 mm 1.0 mm 1.2 mm

Depth of field 0 to 45 mm (0 to 1.77 inches)*1 0 to 85 mm (0 to 3.35 inches)*2 0 to 200 mm (0 to 7.87 inches)*3 100 to 400 mm (3.94 to 15.75 inches)*4 120 to 450 mm (4.72 to 17.72 inches)*5

(4.92 mils) (5.91 mils) (12.99 mils) (39.37 mils) (47.24 mils)

*1 Under the following conditions:

*4 Under the following conditions:

- Ambient illuminance: 500 x. (Fluorescent lamp) - CODE39, 19-digit Narrow bar : Wide bar = 1 : 2.2 - Reflection intensity of white bars: 85% min. Reflection intensity of black bars: 5% max.

- Ambient illuminance: 500 x. (Fluorescent lamp) - ITF conforming to the UPC Shipping Container Code - Reflection intensity of white bars: 85% min. Reflection intensity of black bars: 5% max. - 1.0 magnification

*2 Under the following conditions: - Ambient illuminance: 500 x. (Fluorescent lamp) - CODE39, 6-digit Narrow bar : Wide bar = 1 : 2.2 - Reflection intensity of white bars: 85% min. Reflection intensity of black bars: 5% max. *3 Under the following conditions: - Ambient illuminance: 500 x. (Fluorescent lamp) - EAN13, 1.0 magnification - Reflection intensity of white bars: 85% min. Reflection intensity of black bars: 5% max.

*5 Under the following conditions: - Ambient illuminance: 500 x. (Fluorescent lamp) - ITF conforming to the UPC Shipping Container Code Narrow bar : Wide bar = 1 : 2.2 - Reflection intensity of white bars: 85% min. Reflection intensity of black bars: 5% max. - 1.2 magnifications

129

Page 146

[ 3 ] Interface Specifications Optical Interface Synchronization:

Start-stop

Input signals:

RD

Output signals:

SD

Transmission speed:

115,200 bps max.

Direct-connect Interface Synchronization:

Start-stop

Transmission speed:

115,200 bps max.

Signal level:

Conforms to the RS-232C interface

Pin assignment:

As shown below.

SD

Pin No.

Signal

1

SG (GND)

2 3

RD

GND

Signal Input/Output External BHT-7000 device

Functions

Ground for signals, SD

Send data

→

RD

Receive data

←

130

Page 147

Appendices

A.2 CU-7000 [ 1 ] Product Specifications Power Source - Europe

230 VAC, 16 VA

- U.S.

120 VAC, 13 VA

- Australia

10 to 18 VDC, 450 mA (on 12 VDC)

Power Consumption

8 VA

Dimensions (W) x (L) x (H)

112 x 148 x 84 mm (4.41 x 5.83 x 3.31 inches)

Weight

CU-7001: Approx. 230 g (Approx. 8.11 oz.) CU-7002: Approx. 200 g (Approx. 7.06 oz.)

Operating Ambient Temperature

0˚C to 40˚C (32˚F to 104˚F)

Operating Humidity

20% to 80% (with no dew condensation)

[ 2 ] Charging Requirements (CU-7001) Charge current:

600 mA

Charge time:

Approx. 4 hours

131

Page 148

[ 3 ] Interface Specifications 13

1

25

14

RS-232C Interface Port (Dsub-25S) on the CU-7000

Pin No.

Signal

1 2 3 4 5 6 7 8 20

FG SD RD RS CS DR SG CD ER

NOTE

Signal Input/Output External CU-7000 device

Functions Frame ground Send data Receive data Request to send Ready to send Data set ready Signal ground Carrier detect Data terminal equipment ready, → ←, - - - - - Shown below is a diagram of the internal connection in the CU-7000.

Host computer, modem, or other devices

CU-7000

Signal Name

Pin No.

FG

1

SD

2

RD

3

RS

4

CS

5

DR

6

ER

20

CD

8

SG

7

Optical Interface Not used. RS-232C Interface Circuitry

132

Optical Communications Interface Circuitry

BHT-7000

Page 149

Appendices

Appendix B. Communications Protocol Details B.1

BHT-protocol

[ 1 ] Transmission Control Sequences Shown below is a typical message transmission sequence supported by the BHTprotocol. This sequence example does not include transmission errors or negative responses. Sending Station

Establishment of Data Link (Phase 1)

Receiving Station

ENQ ACK

S O H

Heading text

E B T C X C ACK

S T Serial number X

Data text 1

E B T C X C ACK

Data Transmission (Phase 2)

S T Serial number X

Data text n-1

E B T C X C ACK

S T Serial number X

Data text n

E B T C X C ACK

Release of Data Link (Phase 3)

EOT ACK

133

Page 150

Data transmission may accidentally involve various types of errors. The BHT-protocol is designed to recover from those errors as frequently as possible. What follows is the BHT-protocol for phases 1 through 3.

Phase 1: Establishment of Data Link ■ Normal phase 1 The sending station transmits an ENQ to the receiving station. Upon receipt of an ACK from the receiving station, the sending station shifts to phase 2.

ENQ

Sending station

Receiving station

ACK

To phase 2.

■ Phase 1 with iterated ENQ transmission due to no response or invalid response If the sending station receives no response or any invalid response from the receiving station in response to an ENQ sent, it iterates sending of an ENQ at threesecond intervals up to 10 times. If the sending station receives an ACK before sending an ENQ ten times, it shifts to phase 2. Sending station 3 seconds

ENQ

Receiving station

ENQ 3 seconds

ENQ

ACK

To phase 2.

TIP