Page 125
Chapter 4. Easy Pack 4.2
■ File Setting Conditions to be Registered Enter the following conditions from the keypad according to the messages shown on the LCD: (1) File number
Select a file number from 1 to 4 (PACK1.DAT to PACK4.DAT).
(2) ID-related conditions: ID entry
Select Yes or No.
ID entry method
Select "Barcode & Key", "Barcode", or "Key".
Bar code type
Select a desired bar code type from the seven types given below.
EAN
Universal product codes: EAN-13, EAN-8, UPC-A, and UPC-E
ITF (Interleaved 2 of 5) - Select whether the check digit should be enabled or disabled. - Designate the minimum and maximum numbers of digits for an ID-code field.* NW7 (CODABAR) - Select whether the check digit should be enabled or disabled. - Designate the minimum and maximum numbers of digits for an ID-code field.* CODE39
- Select whether the check digit should be enabled or disabled. - Designate the minimum and maximum numbers of digits for an ID-code field.*
CODE93
- Designate the minimum and maximum numbers of digits for an ID-code field.*
CODE128
- Designate the minimum and maximum numbers of digits for an ID-code field.*
MULTI (Multi-code reading)** All of the above 6 types of bar codes can be read. - Select whether the check digit should be enabled or disabled. - Designate the minimum and maximum numbers of digits for an ID-code field.* *
The number of digits should be within the range from 1 to 40. Once the maximum number of digits for an item field is registered, any data exceeding it cannot be entered in both keypad entry and bar code entry.
** To read EAN-13 or UPC-A bar codes when you have selected multi-code reading, it is necessary to set at least 13 digits each for an ID-code field and data item field. If you have selected multi-code reading, ITF bar codes having less than 4 digits cannot be read.
115
Page 126
(3) Data-related conditions: Number of items
Set 1 to 4 items.
Data entry method
Select "Barcode & Key", "Barcode", or "Key."
Bar code type
Select a desired bar code type from the seven types given below.
EAN
Universal product codes: EAN-13, EAN-8, UPC-A, and UPC-E
ITF (Interleaved 2 of 5) - Select whether the check digit should be enabled or disabled. - Designate the minimum and maximum numbers of digits for a data item field.* NW7 (CODABAR) - Select whether the check digit should be enabled or disabled. - Designate the minimum and maximum numbers of digits for a data item field.* CODE39
- Select whether the check digit should be enabled or disabled. - Designate the minimum and maximum numbers of digits for a data item field.*
CODE93
- Designate the minimum and maximum numbers of digits for a data item field.*
CODE128
- Designate the minimum and maximum numbers of digits for a data item field.*
MULTI (Multi-code reading)** All of the above 6 types of bar codes can be read. - Select whether the check digit should be enabled or disabled. - Designate the minimum and maximum numbers of digits for a data item field.* *
The number of digits should be within the range from 1 to 40. Once the maximum number of digits for an item field is registered, any data exceeding it cannot be entered in both keypad entry and bar code entry.
** To read EAN-13 or UPC-A bar codes when you have selected multi-code reading, it is necessary to set at least 13 digits each for an ID-code field and data item field. If you have selected multi-code reading, ITF bar codes having less than 4 digits cannot be read.
116
Page 127
Chapter 4. Easy Pack 4.2
How to Create Data Files Pressing 1 key on the manager's menu displays the start screen to create files. If no data files have been created, four files should appear on the LCD. In the typical operation flow given below, files 1 and 2 have been created so that files 3 and 4 appear.
●
Selecting a file number Select a file number for a data file to be created. In this sample, press 3 key.
==`êÉ~íÉ=cáäÉ
==PWcáäÉP=QWcáäÉQ
⇓
==cáäÉP ===fåéìí=fa=\ ========NWvÉë=OWkç
●
Designating ID-related conditions Select whether or not it is necessary to set the ID-related conditions. If necessary, press 1 key; if not necessary, press 2 key. If 2 key is pressed, the screen skips to another screen for setting the data-related conditions.
⇓
==cáäÉP=fa
If 1 key is pressed on the previous screen, the screen shown at left appears, prompting you to select the ID code entry method.
==NW_~êÅçÇÉChÉó ==OW_~êÅçÇÉ=PWhÉó
To use both the bar code entry and keypad entry, press 1 key. To use only the bar code entry, press 2 key. To use only the keypad entry, press 3 key.
⇓
If 3 key is pressed, the screen skips to another screen for designating the number of digits for a field.
117
Page 128
==fa=====QW`labPV ==NWb^k==RW`labVP ==OWfqc==SW`labNOU ==PWktT==TWjriqf
If 1 or 2 key is pressed on the previous screen, the screen shown at left appears, prompting you to select the bar code type. Select a desired bar code type by pressing the corresponding numerical key. If 1 key is pressed, the screen shifts to the next field setting screen. If 5 or 6 key is pressed, the screen skips to another screen for designating the minimum number of digits for an ID code field.
⇓
==`ÜÉÅâ=aáÖáí ==NWbå~ÄäÉ ==OWaáë~ÄäÉ
If 2 , 3 , 4 , or 7 key is pressed on the previous screen, the screen shown at left appears, prompting you to select whether the check digit should be enabled or disabled. To enable it, press 1 key; to disable it, press 2 key.
⇓
==cáäÉP=fa
Designate the minimum number of digits for an ID-code field by using the numerical keys. Then, press ENT key.
==jáåZN
When you have selected the EAN bar code for ID entry, the number of digits for an ID code field is automatically set to 13. When you have selected the MULTIcode reading and you are to read EAN13 or UPC-A, it is necessary to set the number of digits to at least 13.
⇓
==cáäÉP=fa ==jáåZN ==j~ñZ|
Designate the maximum number of digits for an ID-code field by using the numerical keys. Then, press ENT key. This completes setting the ID-related conditions.
Once the maximum number of digits is registered, any data exceeding it cannot be entered in both keypad entry and bar code entry.
⇓ 118
Page 129
Chapter 4. Easy Pack 4.2
● Designating data-related conditions
==cáäÉPWkçKçÑ =============áíÉãë
Enter the number of data items for a record by using the numerical keys. (Up to four data items can be set.) Press ENT key.
==Z|=======Ej~ñKQF ⇓
Like the setting of the ID-related conditions, set the data-related conditions including the data entry method, the bar code type, and the minimum and maximum numbers of digits for a data item field.
==cáäÉPWfíÉã=^
When you have selected the EAN bar code for data entry, the number of digits for a data item field is automatically set to 13.
==NW_~êÅçÇÉChÉó ==OW_~êÅçÇÉ=PWhÉó
When you have selected the MULTIcode reading and you are to read EAN13 or UPC-A, it is necessary to set the number of digits to at least 13.
⇓ If the registered number of data items is one, the screen will automatically return to the manager's menu.
==cáäÉPWfíÉã=_ ==NW_~êÅçÇÉChÉó ==OW_~êÅçÇÉ=PWhÉó
If the registered number of data items is more than one, repeat the above data-related condition setting procedure by the registered number. Upon completion of setting for all data items, the screen will automatically return to the manager's menu.
119
Page 130
[ 2 ] "Delete File" Mode You can delete files containing both data collected in the "Collect Data" mode of the user's menu and the file conditions created in the "Create File" mode of the manager's menu.
The "Delete Data" mode of the user's menu erases only the data in the desired file. The file number of a file deleted in this mode reappears on the "Create File" mode screen, allowing you to use it for other applications. Pressing 2 key on the manager's menu displays the screen showing the existing file numbers.
In the sample shown at left appear files 1 and 3 which exist.
==aÉäÉíÉ=cáäÉ
Select the file to be deleted by using the numerical keys.
==NWcáäÉN ==PWcáäÉP
Upon completion of deletion, the screen will automatically return to the manager's menu.
If the above operation results in no file existing in the RAM, the message "File not found!!" appears and the beeper beeps three times.
[ 3 ] "Set Condition" Mode You can modify the communications parameters in this mode. Listed below are the communications parameter defaults in Easy Pack 4.2. Communications Parameters
Defaults
Transmission speed (Bit rate)
19200 bps
Character length
8 bits
Parity
None
Stop bits
1 bit
Protocol Serial number
Enabled
Horizontal parity (BCC)
Enabled
RS/CS control
OFF
120
Page 131
Chapter 4. Easy Pack 4.2
Pressing 3 key on the manager's menu displays the screen as shown below.
==pÉí=`çåÇáíáçå ==NWpéÉÉÇ===OWa~í~ ==PWm~êáíó==QWpíçé ==RWmêçíçÅçä
Press each of 1 through 5 keys to shift to a desired setting screen. 1
:
Transmission speed setting
2
:
Character length setting
3
:
Parity setting
4
:
Stop bit setting
5
:
Protocol setting
● Setting the transmission speed, charac- ter length, parity, and stop bits
==péÉÉÇ===NW==PMM ==OW=SMM==PW=NOMM ==QWOQMM==RW=QUMM ==SWVSMM==TWNVOMM
Pressing 1 key on the above screen displays the screen shown at left. The current setting is reverse-displayed. In this sample, the transmission speed (bit rate) is set to 19200 bps. Select a desired speed by pressing the corresponding numerical key, and your selection is registered and the screen automatically returns to the "Set Condition" menu.
==a~í~ ==NWTÄáíë=OWUÄáíë
==m~êáíó ==NWkçåÉ==OWlÇÇ ==PWbîÉå
Pressing 2 key on the "Set Condition" menu displays the screen shown at left. Select a desired character length by pressing the corresponding numerical key, and your selection is registered and the screen automatically returns to the "Set Condition" menu.
Pressing 3 key on the "Set Condition" menu displays the screen shown at left. Select a desired parity condition by pressing the corresponding numerical key, and your selection is registered and the screen automatically returns to the "Set Condition" menu.
121
Page 132
==píçé
Pressing 4 key on the "Set Condition" menu displays the screen shown at left.
=NWNÄáí==OWÄáíë
Select a desired stop bit length by pressing the corresponding numerical key, and your selection is registered and the screen automatically returns to the "Set Condition" menu.
● Setting the protocol
==mêçíçÅçä ==pÉêá~ä=kçK ==NWlk===OWlcc
Pressing 5 key on the "Set Condition" menu displays the screen shown at left. First, select whether or not the data block serial number should be added by pressing the corresponding numerical key.
⇓
==mêçíçÅçä
Next, select whether or not the horizontal parity should be added by pressing the corresponding numerical key.
==eKm~êáíó ==NWlk===OWlcc
==mêçíçÅçä ==opL`p=`çåíêçä ==NWlk===OWlcc
Select whether or not the RS/CS control should be done by pressing the corresponding numerical key, and your selections above are registered and the screen automatically returns to the "Set Condition" menu.
122