Page 116

4.3 Operating in Easy Pack 4.2 4.3.1 User's Menu The user's menu is designed for applications to be handled by users or operators. The user's menu screen displays the four modes as shown below. Press any of 1 to 4 keys to select a desired mode. To return to the user's menu screen from each mode, press F1 key. To shift to the manager's menu screen, press F4 while holding down SF key.

User's Menu Screen

==NW`çääÉÅí=a~í~ ==OWpÉäÉÅí=cáäÉ ==PWqê~åëãáí=cáäÉ ==QWaÉäÉíÉ=a~í~

1

"Collect Data" mode : Collects data by reading a bar code or entering it from the keypad.

2

"Select File" mode

3

"Transmit File" mode : Transmits data files to the host computer.

4

"Delete Data" mode : Deletes collected data.

: Selects the data file already prepared, according to the applications.

106

Page 117

Chapter 4. Easy Pack 4.2

[ 1 ] "Collect Data" Mode In this mode, you can read bar codes and enter data from the keypad. You can also refer to or modify the ID code and data entered previously. Before accessing this mode, it is necessary to prepare a data file in the "Create File" mode of the manager's menu (refer to Subsection 4.3.2, [ 1 ]). Also, you should select a desired file number in the "Select File" mode of the user's menu. Pressing 1 key on the user's menu displays either of the following screens, depending upon whether the ID code entry has been selected or not in the "Create File" mode of the manager's menu. Current date

File number

Data item

==cáäÉN===ONJMVJVP ==fa|

==cáäÉN===ONJMVJVP ==^W|

=====jriqf=h=MMMMN

=====jriqf=h=MMMMN

ID item

Bar code type

Keypad entry availability

[ When the ID code entry has been selected ]

Record number

[ When the ID code entry has not been selected ]

File number

1 to 4

File number selected in the "Select File" mode

Current date

DD-MM-YY

Day, month, and year

Item designation

ID item Data item

ID code Data item codes A to D (Up to 4 data items are available.)

Bar code type

EAN ITF NW7 CODE39 CODE93 CODE128 MULTI (No indication)

EAN-13, EAN-8, UPC-A, or UPC-E Interleaved 2 of 5 CODABAR (NW7) CODE39 CODE93 CODE128 Multi-code reading Bar code entry not available

Keypad entry

K (No indication)

Keypad entry available Keypad entry not available

Record number

00001-32767 107

Page 118

If the ID code entry has been selected in the "Create File" mode, enter a desired ID code (by bar code entry or keypad entry). Next, read bar codes or enter data from the keypad according to the preset conditions. When the BHT-4000 shifts to this "Collect Data" mode at the second use of this mode or later, it becomes ready to accept data at the record area immediately following the last record previously collected.

How to Collect Data Supposing that a data file has been prepared in the "Create File" mode according to the conditions listed below, the data collecting procedure is described below.

File number

1

ID code to be registered (from keypad)

2 digits

Number of data items (Number of fields)

2

Data item A (bar code entry)

8 digits

Data item B (keypad entry)

2 digits

Number of entered records

10

==cáäÉN===ONJMVJVP ==faOP|

Enter the ID code. If the ID code is 23, for example, press 2 , 3 , and ENT keys.

===========h=MMMNN ⇓

==^WNOPQRSTU ==_W| ===========h=MMMNN ⇓

Scan a bar code to be entered to data item A. If a CODE39 bar code whose value is 12345678 is read, for example, the value appears on the LCD as shown at left, the beeper beeps, and the reading confirmation LED illuminates in green. Then, the screen becomes ready to accept data from the keypad for data item B.

108

Page 119

Chapter 4. Easy Pack 4.2

At this stage, the read data appears in data item "A" but it is not yet registered into the data file. To register the data, be sure to enter data for all of the specified data items of the record and then press ENT key. If data entry (either with keypad or bar codes) is not necessary, skip the data item by pressing ENT key. If you turn off the power without completing the entry for all data items of the record and pressing ENT key, the read data for data item A will be lost when the resume function is deactivated in System Mode (refer to Subsection 2.4.3 [ 4.6 ] Setting the resume function and shift-key function.)

==_WNO ==^W|

Enter data for data item B from the keypad, and then press ENT key. The entered data appears in data item B and the beeper beeps.

=====jriqf===MMMNO

If you press 1 and 2 keys and then ENT key, for example, Easy Pack starts registering the entered ID code, data for data items A and B, and the current date into the data file as a unit of record. Repeating the above operation accumulates records in the data file.

109

Page 120

How to Review and Modify Data You can review the previously entered data, by using F5 and F7 keys. While the data is being reviewed, the reference mark shown below appears on the screen. On this screen, you may modify the displayed data.

==^WQVQMMQRU

▲ ==x==z=======MMMNM ▼

Each time you press F5 key, the screen scrolls up so as to show data entered to the preceding data items starting from the last data; each time you press F7 key, the screen scrolls down. To return to the screen ready for data entry, press ENT key.

Reference mark

When the screen shows the data to be modified, press C key to erase the old data and enter the new in the same way as for normal data collection. Upon completion of new data entry, the new data will be automatically registered into the data file. To return to the screen ready for data entry, press ENT key.

If any modification is made, the date will be automatically updated to that day.

[ 2 ] "Select File" Mode In this mode, you can select a desired data file suitable to the specific application from the previously defined files, just by pressing the corresponding numerical key. Pressing 2 key on the user's menu displays the screen showing only the previously prepared files. The screen example shown below indicates that file 1 and file 2 have been defined.

==pÉäÉÅí=cáäÉ

Use any of the 1 to 4 keys to select a desired data file, and the screen automatically shifts to the user's menu screen.

==NWcáäÉN=OWcáäÉO

In this example, press 1 or 2 key.

110

Page 121

Chapter 4. Easy Pack 4.2

[ 3 ] "Transmit File" Mode This mode allows you to transmit (upload) the currently selected data file to the host computer. Pressing 3 key on the user's menu displays the screen as shown below. What follows is a typical procedure for uploading file 1.

==qê~åëãáí=cáäÉ

Press 1 key to start transmitting data file 1. (To return to the user's menu, press 2 key.)

==cáäÉN=\ ========NWvÉë=OWkç ⇓

==qê~åëãáí=cáäÉ ==cáäÉN=ÄÉáåÖ=ëÉåí =======MMNOPLMMRMM Current record number being transmitted

While the file transmission is in progress, the communications monitor function displays the current record number (serial number) being transmitted and the total number of the records to be transmitted on the LCD, making it easy to check the file transmission status. To abort the file transmission in progress, press C key.

Total number of records to be transmitted

⇓

==qê~åëãáí=lh=> ==aÉäÉíÉ=cáäÉN=\ ========NWvÉë=OWkç

Upon normal end of file transmission, the BHT-4000 beeps and displays the message asking whether or not the data in the transmitted data file should be deleted. To delete the data, press 1 key. The beeper beeps and the screen shifts to the user's menu. To retain the data, press 2 key. The screen shifts to the user's menu.

If a communications error occurs during file transmission or you abort the file transmission by pressing C key, the BHT-4000 displays the error message shown at left and beeps three times. To retry file transmission, press 1 key; to cancel it and return to the user's menu screen, press 2 key.

==qê~åëãáí=Éêêçê>> ==oÉíêó=cáäÉN=\ ========NWvÉë=OWkç 111

Page 122

[ 4 ] "Delete Data" Mode You can delete current data collected in the "Collect Data" mode and registered in the selected data file, without erasing the file conditions prepared in the "Create File" mode of the manager's menu. Pressing 4 key on the user's menu displays the screen as shown below.

==aÉäÉíÉ=a~í~

To delete data, press 1 key. The beeper beeps and the screen shifts to the user's menu.

==cáäÉN=\ ========NWvÉë=OWkç

To cancel this operation, press 2 key. The data remains as it is and the screen shifts to the user's menu.

Difference between the "Delete Data" mode in the user's menu and the "Delete File" mode in the manager's menu is the following: The "Delete Data" mode erases only the data in the file; the "Delete File" mode erases the file itself. For data files which are unnecessary, use the "Delete File" mode.

112

Page 123

Chapter 4. Easy Pack 4.2

4.3.2 Manager's Menu The manager's menu is designed for applications to be managed by system supervisors. The manager's menu screen displays the three modes as shown below. Press any of 1 to 3 keys to select a desired mode. To return to the manager's menu screen from each mode, press F4 key while holding down SF key. To shift to the user's menu screen, press F1 key.

Manager's Menu Screen

==j~å~ÖÉê}ë=jÉåì ==NW`êÉ~íÉ=cáäÉ ==OWaÉäÉíÉ=cáäÉ ==PWpÉí=`çåÇáíáçå

Manager's menu 1

"Create File" mode

: Creates new data files.

2

"Delete File" mode

: Deletes data files.

3

"Set Condition" mode : Sets the communications parameters.

113

Page 124

[ 1 ] "Create File" Mode What you should do first before starting data collection in Easy Pack 4.2 is to select this "Create File" mode and create a data file where the collected data is to be stored. This mode allows you to create data files matching the practical data collection applications by interactive key operations. In this mode, you should set the ID-related conditions and data-related conditions.

■ Data File Structure Generally a data file is made of one or more records having the same data type. A record consists of one or more fields. In Easy Pack 4.2, a data file is made of a maximum of 32767 records and a record consists of a maximum of six fields, as illustrated below. The six fields are used for four data items (4 fields), ID item (1 field), and date (1 field). The data items are called data items A, B, C, and D in the order of entry. Each item field will be occupied by one operator entry job. The date field, which is automatically assigned in a record, contains 10-digit character string (two digits each for year, month, day, hour, and minute). In the inventory application, for example, a record is a set of data consisting of the merchandise name (data item A) field and quantity (data item B) field.

Item (field)

Data file

File 1 Record

ID item (ID code field)

Data Data Data Data item item item item A B C D 144424443 Date field (Data item fields)

114