Page 73

Chapter 2. Getting Started the BHT-4000 and System Mode

[ 5.4 ] LCD, reading confirmation LED, and marker LEDs tests Selecting "LCD" on the TEST MENU displays the test pattern shown at left on the LCD and turns on the reading confirmation LED in green. Each time ENT key is pressed, the screen shifts to the next test pattern. To stop this test in progress, press C key.

⇓

ENT key

The screen shown at left appears and the reading confirmation LED lights in red.

⇓

ENT key

The checker pattern shown at left appears, the reading confirmation LED goes off, and the marker LEDs come on to display the markers.

⇓

ENT key

The checker pattern is reversed and the marker LEDs go off.

⇓

ENT key

63

Page 74

⇓

ENT key

The fine checker pattern shown at left appears.

⇓

ENT key

The fine checker pattern is reversed.

⇓

ENT key

⇓

ENT key

After showing all of the test patterns, the screen automatically displays symbols, and alphanumerics. Upon completion of this test, the BHT-4000 beeps once and returns to the TEST MENU screen.

64

Page 75

Chapter 2. Getting Started the BHT-4000 and System Mode

[ 5.5 ] Aging test TEST AGING DATE

93/10/20

TIME

15:00:00

Selecting "Aging" on the TEST MENU proceeds to the aging test while showing the current date and time on the LCD. (This test is intended for personnel which check the BHT-4000 in the factory.) To return to the TEST MENU screen, press C key.

Once this test is selected, the automatic powering-off function becomes disabled. Be sure to turn the power off or press C key to return to the TEST MENU screen.

[ 5.6 ] Communications test Before starting the communications test in System Mode, it is necessary to jump back the RS-232C interface ports on the CU-4000 and on the BHT-4000 with the testing connectors arranged as shown on the next page.

Interface port

Testing connectors required

Optical interface port on the CU-4000

25-pin D-sub connector (DB-25P)

Direct-connect interface port on the BHT-4000

QM connector

65

Page 76

Preparation for the communications test (1) Jump back the optical interface port on the CU-4000 Arrange the Dsub-25P (DB-25P) connector as illustrated below and connect it to the interface port on the CU-4000. Pin No.

SD

2

RD

3

RS

4

CS

5

(2) Jump back the direct-connect interface port on the BHT-4000 Arrange the QM connector as illustrated below, then connect it to the direct-connect interface port on the BHT-4000. Pin No.

SD

2

RD

3

2

4

6

8

RS

4

1

3

5

7

CS

5

CD

6

ER

7

(Test loop terminating connector)

(3) Place the BHT-4000 on the CU-4000.

66

Page 77

Chapter 2. Getting Started the BHT-4000 and System Mode

TEST COMMUNICATION

Selecting "Com" on the TEST MENU displays the screen shown at left. 1 Optical

1:Optical 2:Connector

: Tests the optical interface port.

2 Connector : Tests the direct-connect interface port. Select the interface port to be tested by using the numerical keys, then press ENT key.

TEST COMMUNICATION < Optical > ** Testing **

TEST COMMUNICATION < Optical >

During the test, the screen shown at left is displayed, showing the selected interface port (optical or direct-connect interface) in the center of the LCD. (This example is testing the optical interface port.)

If an error occurs, the beeper beeps three times and the error message shown at left appears. Press C key to return to the TEST MENU screen.

** Test NG **

TEST COMMUNICATION < Optical > ** Test OK **

Upon normal completion of the test, the BHT-4000 beeps once and displays the screen shown at left. Press C key to return to the TEST MENU screen.

67

Page 78

[ 5.7 ] Beeper test TEST

BEEPER

Selecting "Beeper" on the TEST MENU displays the screen shown at left and makes the beeper sound at three octaves. Upon completion of this test, the BHT-4000 automatically returns to the TEST MENU screen. To stop this test in progress, turn the power off and on.

68

Page 79

Chapter 2. Getting Started the BHT-4000 and System Mode

[ 6 ] System Program Version & RAM Capacity SYSTEM/RAM INFORMATION SYSTEM Ver. X.XXX RAM

: XXXXKB

Selecting "Version" on the SYSTEM MENU displays the screen shown at left, indicating the System Program version and the RAM capacity. Press C key to return to the SYSTEM MENU screen.

69

Page 80

70