Page 64

[ 4.5 ] Setting the communications parameters and interface port When the BHT-4000 is initialized, the communications parameters and the interface port to be used are set as listed in the default table below. Do not access unless necessary. Communications parameters Transmission speed (Bit rate)

19,200 bps

Character length

8 bits

Parity

None

Stop bits

1 bit

Protocol

Serial number ON:

Adds serial numbers to data blocks.

Horizontal parity ON:

Enables horizontal parity cheking.

RS/CS control OFF:

Disables the RS/CS control.

Interface port

SET COM ENVIRONMENT 1:Optical

Optical interface port

Selecting "Com" on the SET SYSTEM menu displays the screen shown at left. 1 Optical

2:Connector 3:Default

: Shifts to the communications parameter menu screen for the optical interface. (The CU-4000 is required.)

2 Connector : Shifts to the communications parameter menu screen for the direct-connect interface. 3 Default

: Shifts to the interface port setting screen.

Select a desired item by using the numerical keys and then press ENT key to shift to the selected setting screen. To return to the SET SYSTEM menu, press C key.

54

Page 65

Chapter 2. Getting Started the BHT-4000 and System Mode

Setting the communications parameters SET COM OPTICAL 1:Speed

2:Data

3:Parity

4:Stop bit

Selecting "Optical" or "Connector" on the SET COM ENVIRONMENT menu displays the corresponding screen shown at left. The selected interface port (OPTICAL or CONNECTOR) is shown on the 2nd line of the LCD.

5:Protocol

SET COM CONNECTOR 1:Speed

2:Data

3:Parity

4:Stop bit

5:Protocol

1 Speed

: Shifts to the speed setting screen where you may select the transmission speed: 300, 1200, 2400, 4800, 9600, 19200, 38400* bps, or High Speed.** (*38400 bps is available only when the direct-connect interface port has been selected.) (**The "High Speed" is available only in Transfer Utility, provided that the RS-232C interface cable is specially connected. Refer to Chapter 3, Subsection 3.1.2.)

2 Data

: Shifts to the character length setting screen where you may select 7 or 8 bits.

3 Parity

: Shifts to the parity setting screen where you may select none, even, or odd parity.

4 Stop bit : Shifts to the stop bit setting screen where you may select 1 or 2 bits. 5 Protocol : Shifts to the protocol setting screen where you may set the following: - Serial On/Off:

Selects whether or not the system should add serial numbers to data blocks.

- Parity On/Off:

Selects whether or not the system should add a horizontal parity.

- RS/CS Control On/Off:

Selects whether or not the system should control the RS/CS signal.

Select a desired item by using the numerical keys and press ENT key to shift to the corresponding setting screen. To return to the previous screen, press C key.

55

Page 66

Setting the interface port SET COM DEFAULT BASIC 1:Optical 2:Connector

Selecting "Default" on the SET COM ENVIRONMENT menu displays the screen shown at left. BASIC

SYSTEM MODE 3:Optical 4:Connector

: Selects the optical or direct-connect interface port to be used for user programs written in BHTBASIC 3.0 ("COM." or XFILE statements) or for Easy Pack 4.2.

SYSTEM MODE : Selects the optical or direct-connect interface port to be used for downloading and uploading files in System Mode.

Select a desired setting by using the numerical keys and press ENT . To return to the SET COM ENVIRONMENT menu screen, press C key.

56

Page 67

Chapter 2. Getting Started the BHT-4000 and System Mode

[ 4.6 ] Setting the resume function and shift-key function SET OTHERS Resume 1:ON

2:OFF

[SF]key 3:NonLock 4:OneTime

Selecting "Others" on the SET SYSTEM menu displays the screen shown at left. Reversed are the current settings. Resume : Activates or deactivates the resume function which resumes the display shown before the power was turned off, when the BHT-4000 is powered up. [ SF ] key : Switches the function of key.

SF

NonLock: The keypad will be shifted only when the SF key is held down. OneTime: Once the SF key is pressed, the next one key pressed will be shifted and the following keys will not be shifted. Select a desired setting by using the numerical keys, then press ENT key. To return to the SET SYSTEM menu, press C key.

Reference: The BHT-4000 automatically displays the shift-key icon on the bottom of the LCD (as default) when the keys are shifted. You may erase it by modifying the system status indication setting on the SET DISPLAY menu (refer to [4.2]) or by using the OUT statement in user programs (refer to the "BHT-BASIC 3.0 Programmer's Manual").

57

Page 68

[ 4.7 ] Deleting a user program file or data file Pressing SF and 0 keys on the SET SYSTEM menu screen displays the screen shown at left.

DELETE 1:Program File 2:Data File

1 Program File : Deletes a user program file (including Easy Pack 4.2). 2 Data File

: Deletes a data file.

Select the file to be deleted by using the numerical keys and press ENT key.

⇓

To return to the SET SYSTEM menu, press C key.

DELETE PROGRAM EASYPACK.PD3 SAMPLE1.PD3 SAMPLE2.PD3 SAMPLE3.PD3

The selected file type (PROGRAM or DATA) is shown on the 2nd line of the LCD. In the screen shown at left, the PROGRAM file is selected. If more than one program file is stored in the user area of the RAM as shown at left, use F5 and F7 keys to move the cursor to the program to be deleted and then press ENT key.

⇓ The screen shown at left will appear.

DELETE PROGRAM To delete the program, press 1 key; to cancel, press 2 key.

SAMPLE1.PD3 Delete ? 1:Yes

2:No

⇓ DELETE PROGRAM SAMPLE1.PD3

When the designated file is deleted, the screen shown at left appears. To return to the SYSTEM MENU screen, press C key two times.

** Completed **

58

Page 69

Chapter 2. Getting Started the BHT-4000 and System Mode

[ 5 ] Testing TEST MENU 1:Barcode

2:Memory

3:Key

4:LCD

5:Aging

6:Com

7:Beeper

Selecting "Test" on the SYSTEM MENU displays the screen shown at left. 1 Barcode : Selects the bar-code reading test. 2 Memory : Selects the ROM and RAM tests. 3 Key

: Selects the key entry test.

4 LCD

: Selects the LCD, reading confirmation LED, and marker LEDs tests.

5 Aging

: Selects the aging test.

6 Com

: Selects the communications test.

7 Beeper

: Selects the beeper test.

Select a desired item by using the numerical keys, then press ENT key. To return to the SYSTEM MENU screen, press C key.

If an error occurs in any of the above tests, contact your nearest dealer.

[ 5.1 ] Bar-code reading test TEST BARCODE

Selecting "Barcode" on the TEST MENU displays the screen shown at left. Actually read bar codes with the BHT-4000 and check the read data displayed on the LCD.

59

Page 70

Bar-code type Number of digits of the bar code

TEST BARCODE

B 08 49400403

Upon completion of bar-code reading, the BHT-4000 beeps, turns on the reading confirmation LED in green, and displays the read data together with the bar-code type and the number of data digits.

Data

Listed below is a table showing the relationship between the bar-code types and the identifier letters to be displayed on the LCD. (CODE39 sample) Bar-code Type

TEST BARCODE

M 20 12345678901234567890

ID Letters

EAN-13, UPC-A

A

EAN-8

B

UPC-E

C

Standard 2 of 5 (STF)

H

Interleaved 2 of 5 (ITF)*

I

CODABAR (NW7)

N

CODE39

M

CODE93

L

CODE128

K

*

The BHT-4000 can read only those ITF bar codes having 4 digits or more in length.

To return to the TEST MENU screen, press C key.

60

Page 71

Chapter 2. Getting Started the BHT-4000 and System Mode

[ 5.2 ] ROM and RAM tests TEST MEMORY ROM Testing

TEST MEMORY ROM Test OK RAM Testing xxxx/yyyy

Selecting "Memory" on the TEST MENU displays the screen shown at left and starts testing the ROM and RAM.

Upon normal completion of the ROM test, the BHT-4000 automatically starts testing the RAM. The screen shows the "tested RAM capacity/total RAM capacity" in kilobytes.

TEST MEMORY ROM Test OK RAM Test NG XXXX/YYYY Address : hhmmll Write : AA Read : BB

If any error is detected, the BHT-4000 beeps, shows the message as shown at left, and terminates the test. (This example indicates that an error has occurred in the RAM.) Where, hhmmll: Address where an error has occurred. AA:

Data to write

BB:

Data read out from the RAM

To return to the TEST MENU screen, press C key.

TEST MEMORY ROM test OK RAM Test OK yyyy/yyyy

Upon normal completion of the ROM and RAM tests, the BHT-4000 beeps, shows the message as shown at left, and returns to the TEST MENU screen.

61

Page 72

[ 5.3 ] Key entry test Selecting "Key" on the TEST MENU displays the screen shown at left and makes the BHT4000 ready for entry from the keypad.

TEST KEY

Pressing individual keys displays the identifier letters in the positions preassigned to those keys on the LCD and sounds the beeper. (While the individual key is held down, the beeper continues beeping.) Pressing the same key again erases the displayed letter.

The table below shows the relationship among the keys, the identifier letters to be displayed on the LCD, and the frequencies (Hz) of the beeper. Key

Letter

Beeper (Hz)

Key

Letter

Beeper (Hz)

Key

Letter

Beeper (Hz)

F1 F2

A

261

F8

H

587

2

2

1318

B

293

7

7

659

3

3

1396

F3

C

329

8

8

698

0

0

1567

F4

D

349

9

9

783

.

.

1760

F5

E

391

4

4

880

C

I

1975

SF

_

440

5

5

987

BS

J

2093

F6

F

493

6

6

1046

ENT

=

2349

F7

G

523

1

1

1174

TEST KEY ABCDE_FGH 7894561230.

After all keys are pressed and displayed on the LCD, this test automatically ends and the screen returns to the TEST MENU screen. To stop this test in progress, turn the power off and on.

IJ=

62