Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact
Page 1 of DataMyte 501 Spec Sheet

Spec sheet · DataMyte

DataMyte 501 Spec Sheet

Spec sheet4 pagesPDF 307 KB

All 4 pages are below, each with its text.

Download the PDF307 KB

Covers · 1 model

The models it covers

From the sheet · read page by page

Key facts from this sheet

Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.

A four-page ASI DataMyte spec sheet (2003) for the DataMyte 501, a handheld data collector for gage and bar code data on the factory floor. It describes the four-channel analog gage option with true position and time at level reading, the keypad choices, TranSend software, the SPC option and the hardware specifications.

Device
Handheld data collector for roving gage and bar code data collection p. 2, 3
Display
128 x 128 dot matrix LCD panel; backlit panel optional p. 4
Memory
1000K standard, 2000K optional p. 4
Power
Two AA batteries p. 3, 4
Connectors
1 serial, 1 alarm output, 1 DC power in, 1 gage; analog option adds 1 true position and 2 analog p. 4
Digital gages
Mitutoyo, Chicago Dial Indicator, Federal Maxµm, Ono Sokki, RS232, RS422, RS423, Sylvac Serial; 300 to 38.4 Kbaud p. 4
Analog option
Four channels for LMI, JS and MP Components gages; port G1 digital/serial, G2 and G3 true position, G4 and G5 for LMI 200-, 300- or 700- series p. 2, 4
Size and weight
4.08” x 10.5” x 1.77”; under one pound p. 4
Operating range
0-45°C (32-115°F); 10%-90% noncondensing humidity p. 4
Keypad
Simple (large keys, gloved use) or alphanumeric with dedicated number keys; silicone rubber p. 3, 4
Software
TranSend: builds and downloads setups, uploads data to Excel, tab or comma delimited, or Statistica files p. 3
SPC software
TurboSPC VA 4.3 or higher, Quantum SPC/QA 2.3 or higher, Quantum SPC/RCSL 2.41 or higher p. 4
Drop rating
Four foot drop to concrete without loss of function p. 3
Case
ABS plastic case p. 4

What this sheet walks you through

  • Connecting digital and analog gages to the analog option bulkhead p. 2
  • Real-time true position gaging in two or three axes p. 2
  • Time at Level gage reading with the LMI Model 200 probe p. 3
  • Choosing the simple or alphanumeric keypad p. 3
  • Making setups and uploading data with TranSend p. 3
  • SPC option charts and on-board menu p. 3, 4

Good to know

  • True position gaging and Time at Level reading need the four-channel analog option. p. 3
  • The cable for analog ports 4 and 5 is the same as a standard telephone handset cable. p. 2
  • TranSend works with Excel 5.0, Excel for Office 95/98 (V 7.0) and Excel for Office 97 (V 8.0). p. 4

Questions this sheet answers

What batteries does the DataMyte 501 use?

Two AA batteries. p. 3

How much memory does the DataMyte 501 have?

1000K standard, with 2000K optional. p. 4

Which gages connect to the DataMyte 501?

Digital gages from Mitutoyo, Chicago Dial Indicator, Federal, Ono Sokki and Sylvac plus RS232/RS422/RS423; the analog option adds LMI, JS and MP Components gages. p. 4

Can the DataMyte 501 do true position gaging?

Yes, in two or three axes in real time, with the analog option. p. 2

What software does the DataMyte 501 use?

TranSend, which creates and downloads setups and uploads collected data to spreadsheet or delimited files. p. 3

The file

Size and text

Pages4
PDF307 KB
TextText from the PDF itself; page 1 is a scan, read by OCR, which may hold reading errors.

Every page · 4

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of DataMyte 501 Spec Sheet

The text of page 1, read from a scan by OCR; it may hold reading errors

"ASI DataMy®? “SRA eT Quality Solutions

i

ASI DataMyte 501 Data Collector Breakthrough Technology with handheld convenience

Page 2 of DataMyte 501 Spec Sheet

The text of page 2, from the PDF itself

The DataMyte 501 data collector is a true breakthrough in handheld design. This distinctive unit weighs under one pound and brings new convenience to roving data collection. It is ideal for many data collection operations, especially in confined spaces. The DataMyte 501 features an LCD panel to display collected information, with a backlight option for use in lowlight conditions. The ergonomic design features keys oriented for either right-or left-hand operation. The contoured grip reduces operator fatigue and the likelihood of motion injuries. Analog Capability A four-channel analog option is available for the DataMyte 501. This option is useful for sheet metal applications that use analog gaging, such as those from LMI, MP Components, or JS Gages. These gages are industry standards in automotive assembly, sheet metal stamping, and aircraft rivet height applications. The 501 analog option includes a unique connector bulkhead. The standard digital/serial gage port with caliper icon is designated G1. The true position port with the true position icon (cross hairs) is designated G2 and G3, as this one port supports two analog channels. The true position port supports true position gages from LMI and MP Components, as well as the new 2-4-1 gage from LMI that measures gap & flush simultaneously. The remaining two ports are designated G4 and G5 and either port can be used with LMI 200-, 300-, or 700- series gages. These ports allow for direct connection of the gages they support without costly and cumbersome signal conditioning/switch boxes. The cable for ports 4 and 5 is the same as the cable between the handset and base unit on standard telephones to simplify cable replacement. All of the supported gages can be connected simultaneously. For example, a caliper, a true position probe, a gap & flush gage and an LMI 200 series probe can be used simultaneously to address complex applications without changing cables or gages.

The 501 data collector with analog option can be used with an LMI gap and flush gage

Real-Time True Position Gaging Real-time true position gaging, in two or three axes, is a DataMyte 501 capability with the analog option. True position gaging measures the distance from an actual hole center to its desired position expressed as a diameter in accordance with ANSI standards. The mechanical sensors necessary to measure true position are available from either LMI or Component Engineering. These true position gages have two built-in analog transducers that measure the center deviation of the hole in two 90° displaced coordinates (X axis and Y axis), and these two channels plug into the single true position port on the DataMyte 501 analog board. Connector Bulkhead for 501 Analog Option

With the real-time column display on the DataMyte 501 LCD panel, one column can be used to display X-axis deviation, the second column can be used to display Y-axis deviation and the third column can be used to show the true position deviation. A fourth column may be used to display the Z-axis if required.

Page 3 of DataMyte 501 Spec Sheet

The text of page 3, from the PDF itself

Time at Level Gage Reading Time at Level Gage Reading is another 501 feature included with the four channel analog board option, and works with the LMI Model 200 probe. The Time at Level algorithm overcomes the simple peak algorithm susceptibility to false readings when the measurement probe bumps into the edge of the fixture. The Time at Level algorithm requires the signal from the gage to be steady for a short period of time before the reading is captured. The collector takes the reading, beeps, and provides LED feedback as soon as the Time at Level condition is met.

The toolbelt can hold a DataMyte 501 and a variety of digital and analog gages for roving applications

Using the Time at Level algorithm, readings are more certain and more accurate as well as collected quicker than either the peak or switch-actuated methods. In addition, since 20 to 40 check points on a fixture are not uncommon, less operator hand motion will be needed to actuate the Enter key or switch.

Optional Keypad Configurations The DataMyte 501 supports two different keypad options. The simple keypad is optimized for gage or barcode data collection in a factory environment. It has large, well-spaced keys that may be conveniently operated with even a single gloved hand for most data collection applications. Text, symbols, and numbers are entered via an LCD character pallet. The alphanumeric keypad has dedicated number keys for those applications that require frequent keyed numeric data entry. Text and symbols may be entered using the three “pointer” keys in conjunction with the “Shift” and “Symb” keys. TranSend Communication Software DataMyte’s TranSend™ utility software lets you create and download variables data collection setups as well as upload collected data to an Excel™ spreadsheet, tab delimited, comma delimited or Statistica® file. The TranSend setup editor supports creation of pick lists for both piece and subgroup labels. Making setups with several similar characteristics is easy since copy and paste are supported. Variables characteristics, subgroup and piece labels are also supported.

Standard Features A red/green/yellow LED display provides visual indication of in/out of spec conditions and caution alerts for operators. A standard internal warning buzzer, or an optional lapel buzzer, also serves as a warning indicator. The LEDs are position and color coded for easy recognition, even by operators who are unable to distinguish colors. SPC Option The 501 may be ordered with either the SPC option for on-board SPC analysis, or a non-SPC option. The onboard menu provides these choices: ƒ ƒ ƒ ƒ

ƒ ƒ ƒ ƒ

Choose Setup Review Setup Delete Gage (for gage configuration) ƒ

Off

Export Preferences Views About Screen

Rugged Design The 501 data collector is designed to survive a four foot drop to a concrete surface without loss of function. It resists damage from puddled oil, water-based cutting fluid, abrasives, dust, metal chips and filings. Standard power is two rechargeable commercial AA batteries.

Page 4 of DataMyte 501 Spec Sheet

The text of page 4, from the PDF itself

DataMyte 501 Data Collector Specifications Hardware

Gage InterfacesTranSend Softwareƒ ƒDigitalƒƒ ƒ ƒ ƒ ƒ ƒƒ ƒ ƒ ƒ

Weight: Under one pound Dimensions: 4.08” x 10.5” x 1.77” Construction: Case: ABS plastic; Keypad: Silicone rubber Power supply: Two AA 1.5 V batteries Display: 128 x 128 dot matrix LCD panel; backlit panel optional Audible output: Buzzer with volume and frequency control Numerical precision: 8 digits plus decimal point and sign Connectors: 1 serial, 1 alarm output, 1 DC power in, 1 gage: Analog option adds 1 true position, 2 analog. Operating temp. range: 0-45°C (32-115°F); 10%-90% noncondensing humidity Memory- 1000K standard, 2000K optional Keypad: Simple or alphanumeric Tool belt

Export Feature ƒ ƒ ƒ ƒ ƒ

Data summary Database export Spreadsheet export With or without headers With or without characteristic labels

SPC Option ƒ ƒ ƒ ƒ ƒ ƒ ƒ

x-bar & R control charts and stats x-bar & Σ control charts and statistics SPC histogram and statistics Charts can be automatically graphed as data is collected Trends and out-of-control points indicated on control charts (SPC option) Calculate control limits (SPC option) Enter assignable causes (SPC option)

ƒ

ƒ ƒ

Inputs from Mitutoyo, Chicago Dial Indicator, Federal Maxµm, Ono Sokki,RS232, RS422, RS423, Sylvac Serial Smart serial gage support 300 to 38.4 Kbaud

ƒ ƒ ƒ

TranSend software is compatible with: Excel Version 5.0/Windows 3.1 or Windows for Workgroups 3.11 Excel for Office 95/98 (V 7.0)/ Windows 95/98 or Windows NT Excel for Office 97 (V 8.0)/ Windows 95/98 or Windows NT

Analog ƒ ƒ ƒ ƒ ƒ

Four channel analog option supports LMI, JS and MP Components gages Real time two-or three-axis true position gaging Automatic time at level gage reading Prompted zero before read option 0-1% full scale accuracy

DataMyte, TranSend, Quantum SPC and TurboSPC are trademarks of ASI DataMyte, Inc. Microsoft and Excel are trademarks of Microsoft Corporation.

Other Functions ƒ ƒ ƒ ƒ

Enter, review, retake data Data logging Footswitch input Unreasonable reading actions

Additional Features ƒ ƒ ƒ ƒ ƒ ƒ

Red/green/yellow LCD trend alert Flash memory for field updates Built-in multiple languages Interface compatible with popular electronic gages Password protection Built-in help

The DataMyte 501 is available with an alphanumeric keypad at no extra charge.

Compatibility The 501 is compatible with: ƒ TurboSPC VA software version 4.3 or higher ƒ Quantum SPC/QA™ software version 2.3 or higher ƒ Quantum SPC/RCSL software version 2.41 or higher

Total Quality Solutions www.asidatamyte.com ● Plymouth, MN ● Phone: 763.553.1040 ● Fax: 763.553.1041 Royal Oak, MI ● Phone: 248.543.6040 ● Fax: 248.543.2882 Hasselt, Belgium ● Phone: +32 11 870 830 ● Fax: +32 11 870 833 Copyright 2003, ASI DataMyte, Inc.