Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 9 of 16

TC1100 Reference Manual: 4 Barcode Configuration, pages 72 to 81

Pages 72 to 81 of 131, from TC1100 Reference Manual

The original document is the PDF (979 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic TC1100

Page 72

Enter configuration i i

Exit and Save Configuration

DATA FORMAT k k

HEADER no header i&" i&" i&" k k k one character header

☞ i&" i&" i&" two character header

☞ i&" i&" i&" three character header

☞ i&" i&" i&" four character header

☞ i&" i&" i&" five character header

☞ i&" i&" i&" six character header

☞ i&" i&" i&" seven character header

☞ i&" i&" i&" eight character header

☞ i&" i&" i&"

After selecting one of the desired Header codes, read the character(s) from the HEX table. Valid characters for all readers are in the range:

00-FE

Example: four character header

+ 41 + 42 + 43 + 44 = Header ABCD For more details about default and WEDGE Interface Extended Keyboard values, see pars. 5.3.1 and 5.3.2.

64

Page 73

Enter configuration i i

Exit and Save Configuration

DATA FORMAT k k

TERMINATOR no terminator i&" i&" i&" one character terminator

☞ i&"k i&"k i&"k two character terminator

☞ three character terminator

☞ i&" i&" i&" four character terminator

☞ five character terminator

☞ six character terminator

☞ seven character terminator

☞ eight character terminator

☞

After selecting one of the desired Terminator codes, read the character(s) from the HEX table. Valid characters for all readers are in the range:

00-FE

Example: two character terminator

+ 0D + 0A = Terminator CR LF For more details about default and WEDGE Interface Extended Keyboard values, see par. 5.3.1 and 5.3.2.

65

Page 74

Enter configuration i i

Exit and Save Configuration

DATA FORMAT k k

FIELD ADJUSTMENT disable field adjustment i&' <k i&' <k i&' <k Field adjustment allows a number of characters n, to be added to or subtracted from the barcode read. The adjustment can be different for each enabled code type. To define the field adjustment: Read the enable field adjustment code: enable field adjustment

☞ i&' i&' i&' k k k

Select the code type from the Code Identifier Table in Appendix A. Select the type of adjustment to perform: right addition i k i k i k left addition right deletion k k k left deletion i -k i -k i -k Read a number in the range 01 - 32 from the Hex/Numeric Table to define how many characters to add or delete:

Conditions: •

Adjustment is only performed on the barcode data, the Code Identifier and Code Length Transmission fields are not modified by the field adjustment parameter.

•

If the field setting would subtract more characters than exist in the barcode, the subtraction will take place only to code length 0.

•

You can set up to a maximum of 10 different field adjustments on the same barcode family or on different barcode families.

Example: To add 4 characters to the right of Standard Code 39 Codes: enable field adjustment

Read

66 i&' i&' k k

+

Code 39 right addition i78k i78k i k i k

+

+

04

Page 75

Enter configuration i i

Exit and Save Configuration

DATA FORMAT k k

FIELD ADJUSTMENT CHARACTER Read the field adjustment character code: field adjustment character

☞

Read the hexadecimal value corresponding to the character you want to use for field adjustment.

00-FE

Valid characters for all readers are in the range:

Example: To define the field adjustment character = A: field adjustment character

+ 41

Read

CODE LENGTH TX code length not transmitted i&& :k i&& :k i&& :k code length transmitted in variable-digit format i&&=k i&&=k i&&=k code length transmitted in fixed 4-digit format

The code length is transmitted in the message after the Headers and Code Identifier characters. The code length is calculated after performing any field adjustment operations.

67

Page 76

Enter configuration i i

Exit and Save Configuration

DATA FORMAT k k

CHARACTER REPLACEMENT disable character replacement i&0 Nk i&0 Nk i&0 Nk

This parameter allows up to three characters to be replaced from the barcode read. These substitutions are stored in memory. To define each character replacement:

Read one of the following character replacement codes: first character replacement

☞ i&0Qk i&0Qk i&0Qk second character replacement

☞ third character replacement

☞ i&0 Wk i&0 Wk i&0 Wk

From the Code Identifier Table in Appendix A, read the Code Identifier for the desired code family. 0 = character replacement will be effective for all code families. From the Hex/Numeric Table read two characters corresponding to the Hex value which identifies the character to be replaced. Valid values for all readers are in the range 00-FE. From the Hex/Numeric Table read two characters corresponding to the Hex value which identifies the new character to replace. Valid values for all readers are in the range 00-FE.

FF = the character to be replaced will be substituted with no character, that is, it will be removed from the code.

68

Page 77

DATA FORMAT Example: The following strings define:

1.

First Character Replacement: substitution in Code 39 barcodes of all occurrences of the 0 character with the 1 character.

2.

Second Character Replacement: substitution in Code 39 barcodes of all occurrences of the A character with the B character.

first character replacement

Code 39 i&0Qk + i78k + i&0Qk i78k

ASCII characters corresponding to the HEX value for character 0

30

ASCII characters corresponding to the HEX value for character 1

+

31

For Code 39 codes containing the string "0123", the contents transmitted will be "1123".

second character replacement

Code 39

+ i78k + i78k

ASCII characters corresponding to the HEX value for character A

41

ASCII characters corresponding to the HEX value for character B

+

42

For Code 39 codes containing the string "ABCD", the contents transmitted will be "BBCD".

69

Page 78

Enter configuration i i

Exit and Save Configuration

DATA FORMAT k k

NO READ CHARACTER disable i&1 Pk i&1 Pk i&1 Pk enable i&1Sk i&1Sk i&1Sk

Read the “enable” code above: Read the hexadecimal value corresponding to the character you want to use for no read character.

00-FE

Valid characters for all readers are in the range:

Example: To define the no read character = A: Enable No Read Character i&1Sk i&1Sk i&1Sk

ASCII characters corresponding to the HEX value for character A

+

41 no read character = <CAN>

70

Page 79

POWER SAVE READ RATE SLEEP STATE ENTER SLEEP TIMEOUT STANDBY

1.

Read the Enter Configuration code ONCE, available at the top of each page.

2.

Read configuration codes from the desired groups.

☞

= Read the code and follow the procedure given

= Default value

3.

Read the Exit and Save Configuration code ONCE, available at the top of each page.

71

Page 80

Enter configuration i i

Exit and Save Configuration

POWER SAVE k k

READ RATE 67 reads per sec.

i#5 Uk i#5 Uk i#5 Uk

135 reads per sec.

i#5Xk i#5Xk i#5Xk

270 reads per sec.

A lower read rate reduces power consumption but can lengthen reading response time.

SLEEP STATE disable i#2 Ok i#2 Ok i#2 Ok enable i#2Rk i#2Rk i#2Rk See par. 5.4.1 for details.

72

Page 81

Enter configuration i i

Exit and Save Configuration

POWER SAVE k k

ENTER SLEEP TIMEOUT enter sleep timeout

☞ i#3!k i#3!k i#3!k

Read 2 numbers in the range 00-99: 00 =

Enter Sleep state immediately

01-99 = corresponds to a max. 9.9 sec. delay before entering the Sleep state. enter sleep timeout = 0.6 sec

See par. 5.4.2 for details.

STANDBY disable i#.Jk i#.Jk i#.Jk optimize for reading speed enable i#. Gk i#. Gk i#. Gk optimize for low power consumption

See par. 5.4.3 for details.

73