Page 62

PEN EMULATION The operating mode parameters are complete commands and do not require reading the Enter and Exit configuration codes.

OPERATING MODE interpret mode

Interprets commands without sending them to the decoder.

transparent mode i<-k i<-k i<-k Sends commands to the decoder without interpreting them.

54

Page 63

Enter configuration i i

Exit and Save Configuration

PEN EMULATION k k

MINIMUM OUTPUT PULSE high resolution code emulation

200 µs i%( =k i%( =k i%( =k 400 µs i%(@k i%(@k i%(@k

600 µs

800 µs i%( Fk i%( Fk i%( Fk

1 ms i%(-Ik i%(-Ik i%(-Ik 1.2 ms low resolution code emulation

See par. 5.2.1 for details.

55

Page 64

Enter configuration i i

Exit and Save Configuration

PEN EMULATION k k

CONVERSION TO CODE 39 disable conversion to Code 39 i%" 1k i%" 1k i%" 1k Transmits codes in their original format.

enable conversion to Code 39 i%"4k i%"4k i%"4k Converts codes read into Code 39 format.

56

Page 65

Enter configuration i i

Exit and Save Configuration

PEN EMULATION k k

OVERFLOW narrow i%) ?k i%) ?k i%) ?k medium i%)Bk i%)Bk i%)Bk wide

See par. 5.2.2 for details.

OUTPUT LEVEL normal (white = logic level 0)

i%% 7k i%% 7k i%% 7k inverted (white = logic level 1)

i%%:k i%%:k i%%:k

See par. 5.2.3 for details.

57

Page 66

Enter configuration i i

Exit and Save Configuration

PEN EMULATION

IDLE LEVEL normal (black level)

i%& 9k i%& 9k i%& 9k inverted (white level)

i%&<k i%&<k i%&<k

See par. 5.2.3 for details.

INTER-BLOCK DELAY delay between character blocks transmitted to Host

☞ i$, k i$, k i$, k

Read 2 numbers from the table where: 00 = DELAY disabled 01-99 = DELAY from .1 to 9.9 seconds delay disabled

See par. 5.2.4 for details

58 k k

Page 67

DATA FORMAT NOT FOR PEN INTERFACES

CODE IDENTIFIER CUSTOM CODE IDENTIFIER HEADER TERMINATOR FIELD ADJUSTMENT FIELD ADJ. CHARACTER CODE LENGTH TX CHARACTER REPLACEMENT NO READ CHARACTER

1.

Read the Enter Configuration code ONCE, available at the top of each page.

2.

Read configuration codes from the desired groups.

☞

= Read the code and follow the procedure given = Default value

3.

Read the Exit and Save Configuration code ONCE, available at the top of each page.

59

Page 68

DATA FORMAT

CODE IDENTIFIER TABLE CODE

AIM STANDARD

DATALOGIC STANDARD

2/5 interleaved 2/5 industrial 2/5 normal 5 bars 2/5 matrix 3 bars EAN 8 EAN 13 UPC A UPC E EAN 8 with 2 ADD ON EAN 8 with 5 ADD ON EAN 13 with 2 ADD ON EAN 13 with 5 ADD ON UPC A with 2 ADD ON UPC A with 5 ADD ON UPC E with 2 ADD ON UPC E with 5 ADD ON Code 39 Code 39 Full ASCII CODABAR ABC CODABAR Code 128 EAN 128 ISBT 128 Code 93 CIP/39 CIP/HR Code 32 Codablock-A Codablock-F Std Codablock-F EAN MSI Plessey Standard Plessey Anker Telepen Delta IBM Code 16K Code 49 PDF417 Pharmacode

]Iy ]Xy ]Sy ]Xy ]E4 ]E0 ]Xy ]Xy ]E5 ]E6 ]E1 ]E2 ]Xy ]Xy ]Xy ]Xy ]Ay ]Ay ]Fy ]Xy ]Cy ]Cy ] C4 ]Gy ]Xy ]Xy ]Xy ]O6 ]O4 ]O5 ]My ]P0 ]P1 ]X0 ]X0 ]K0 ]Ty ]L0

N P O Q A B C D J K L M F G H I V W R S T k f U Y e X n l m Z a o d c p q r s

60

Custom

Page 69

DATA FORMAT •

AIM standard identifiers are not defined for all codes: the X identifier is assigned to the code for which the standard is not defined. The y value depends on the selected options (check digit tested or not, check digit tx or not, etc.).

•

When customizing the Datalogic Standard code identifiers, 1 or 2 identifier characters can be defined for each code type. If only 1 identifier character is required, the second character must be selected as FF (disabled).

•

The code identifier can be singly disabled for any code by simply selecting FF as the first identifier character.

•

Write in the Custom character identifiers in the table above for your records.

61

Page 70

Enter configuration i i

Exit and Save Configuration

DATA FORMAT CODE IDENTIFIER disable i&# 4k i&# 4k i&# 4k

Datalogic standard i&#7k i&#7k i&#7k

AIM standard custom i&# =k i&# =k i&# =k

62 k k

Page 71

Enter configuration i i

Exit and Save Configuration

DATA FORMAT k k

CUSTOM CODE IDENTIFIER define custom code identifier(s)

☞

Read the above code. (Code Identifiers default to Datalogic standard, see table on previous page).

Select the code type from the code table in Appendix A for the identifier you want to change.

You can define 1 or 2 identifier characters for each code type. If only 1 identifier character is required, the second character must be selected as FF (disabled). Read the hexadecimal value corresponding to the character(s) you want to define as identifiers for the code selected in step : valid characters are in the range 00-FD.

Example:

To define Code 39 Code Identifier = @ define custom code identifier(s)

Read i&' i&' k k

Code 39

+ i78k i78k

+

40

+

FF

63