Page 12

TC1100

2

2

INSTALLATION

2.1

TC1100 CCD SCANNER

2.1.1

Mechanical Installation

54 [2.13] 24 [0.94]

68.6 [2.70] 10.4 [0.41]

9.5 [0.37]

7.6 [0.30]

70.7 [2.78]

30.5 [1.20]

The diagram below gives the overall dimensions of the reader and may be used for its installation.

31.6 [1.25] mm [in.]

17.7 [0.70]

Optical Axis

Figure 1 - Overall Dimensions

4

Page 13

INSTALLATION

2.1.2

2

Electrical Connections

The TC1100 Scanner is equipped with a 25-pin female D-Sub connector for connection to the power supply and input/output signals. The details of the connector pins are indicated in the following table:

Figure 2 - 25-pin Female D-sub Connector

25-pin Connector 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

Shield TX RX RTS CTS nc SGND EXT BEEPER VCC+ nc OUT+ OUTVCC+ nc nc nc nc EXT TRIG+ EXT TRIGDATAIN_WAND DATAOUT OUTCLKIN CLKOUT GND earth ground transmit data receive data request to send clear to send not connected signal ground external beeper connection +5 Vdc not connected see Figure 10 +5 Vdc not connected not connected not connected not connected See Figures 6 to 9 power ground

Table 1 - TC1100 Scanner Pinout

5

Page 14

TC1100

2

RS232 Interface The TC1100 Scanner can communicate with the Host using the RS232 signals provided on the 25-pin connector. The pins are indicated in Table 1 and in the following diagram: It is always advisable to use shielded cables. The overall maximum cable length must be less than 15 m (49.2 ft). TC1100 25-pin

Host 2

TX

3

RX

TXD

4

RTS

DCD

5

CTS

DTR

7

SGND

RXD

SGND Earth Ground

Figure 3 - RS232 Interface Connection to Host

WEDGE Interface The TC1100 Scanner can communicate with the Host in a WEDGE Interface (Keyboard Emulation) using the signals provided on the 25-pin connector. The pins are indicated in Table 1 and in the following diagram: Host DATA

TC1100 25-pin

CLK

21

DATAOUT

24

CLKOUT

13

VCC+

25

GND

20

DATAIN

23

CLKIN

VCC+ GND

Keyboard VCC+ GND DATA CLK

Figure 4 - Wedge Interface Connection to Host (PC AT) and Keyboard

6

Page 15

INSTALLATION

2

PEN Emulation Interface The TC1100 Scanner can communicate with the Host in a PEN Emulation Interface using the signals provided on the 25-pin connector. The pins are indicated in Table 1 and in the following diagram: TC1100 25-pin

Host 20 WAND

DATA

13 VCC+

VCC+

25 GND

GND Earth Ground

Figure 5 – Pen Emulation Interface Connection to Host

It is always advisable to use shielded cables.

Inputs There is an input available on the TC1100 Scanner relative to the External Trigger. The pins are indicated in Table 1. These inputs are optocoupled and can be driven by both an NPN or PNP type command. The connections are indicated in the following diagrams: TC1100

Vext 30 Vdc max. EXTERNAL TRIGGER

+ 5V 18

EXT TRIG+

19

EXT TRIG-

V

Signal

Figure 6 - Input NPN Command Using External Power

Vext 30 Vdc max.

TC1100

EXTERNAL TRIGGER V

+ 5V 18

EXT TRIG+

19

EXT TRIG-

Signal

Ground

Figure 7 - Input PNP Command Using External Power

7

Page 16

TC1100

2 TC1100

EXTERNAL TRIGGER 13 Vcc 5Vdc

V

+ 5V 18 EXT TRIG+ 19 EXT TRIG25 GND

Signal Ground

Figure 8 - Input NPN Command Using TC1100 Power

TC1100

EXTERNAL TRIGGER 13 Vcc 5Vdc

V

+ 5V

Signal

18 EXT TRIG+ 19

EXT TRIG-

25

GND

Ground

Figure 9 - Input PNP Command Using TC1100 Power

Outputs There is an output available on the TC1100 Scanner relative to the Good Read event. The pins are indicated in Table 1. The connections are indicated in the following diagram:

USER INTERFACE

TC1100 11

OUT +

12

OUT -

Vext 40 Vdc max

Figure 10 - Output Connection (Good Read). Example NPN

8

Page 17

INSTALLATION

2

External Beeper Connection A beeper output signal is provided on pin 8 so that an external piezoelectric buzzer with internal oscillator can be connected for Good Read acoustic signaling. The complete circuit to be built is shown in the schematic diagram below. +5 Vdc (pin 13)

+5 Vdc (pin 13)

+ D1 (1N4148)

BZ1 (see below)

R2 (10K)

BEEPER (pin 8)

Q1 (BC337) R1 (1K)

GND (pin 25)

Figure 11 - TC1100 Scanner Beeper Connection

The following list indicates several piezoelectric buzzers that can be used in the circuitry above (part BZ1). Manufacturer

Type

MURATA DIGISOUND CITIZEN BUJEON

PKB30SPC - 2001/3001 F/TCW05 MEB-12C-5 BS12-A

See chapter 3 for Beeper Control commands.

9

Page 18

TC1100

2

2.2

TC1100 CCD SCAN ENGINE

2.2.1

Mechanical Installation

The diagram below gives the overall dimensions of the TC1100 Scan Engine and may be used for its installation.

63 [2.48]

Veritcal Optical Axis 25.7 [1.01] 12.2 [0.48]

63 [2.48] 40.5 [1.59]

2.5 [0.10]

Ø2.7 [Ø0.11] n°4 18 [0.71]

50 [1.97] mm [ in.]

2.5 [0.10]

57 [2.24]

2.5 [0.10]

28.5 [1.12]

Horizontal Optical Axis

Figure 12 - Overall Dimensions

10

60.5 [2.38]

Page 19

INSTALLATION

2.2.2

2

Electrical Connections

The TC1100 Scan Engine is equipped with two 8-pin DF13 connectors for connection to the power supply and input/output signals. The details of the connector pins are indicated in the following table:

1

J1

1

J2

Figure 13 - 8-pin Connectors

J1 1 2 3 4 5 6 7 8

SGND OUTOUT+ EXT BEEPER CTS RX RTS TX signal ground see Figure 21 beeper output signal clear to send receive data request to send transmit data

J2 1 2 3 4 5 6 7 8

VCC+ GND CLKOUT DATAOUT DATAIN_WAND CLKIN EXT TRIG+ EXT TRIG-

+5 Vdc power ground

See Figures 17 to 20

Table 2 - TC1100 Scan Engine Pinout

11