The text of a manual · part 3 of 16
TC1100 Reference Manual: 2 Installation, pages 12 to 19
Pages 12 to 19 of 131, from TC1100 Reference Manual
The original document is the PDF (979 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic TC1100
Page 12
TC1100
2
2
INSTALLATION
2.1
TC1100 CCD SCANNER
2.1.1
Mechanical Installation
54 [2.13] 24 [0.94]
68.6 [2.70] 10.4 [0.41]
9.5 [0.37]
7.6 [0.30]
70.7 [2.78]
30.5 [1.20]
The diagram below gives the overall dimensions of the reader and may be used for its installation.
31.6 [1.25] mm [in.]
17.7 [0.70]
Optical Axis
Figure 1 - Overall Dimensions
4
Page 13
INSTALLATION
2.1.2
2
Electrical Connections
The TC1100 Scanner is equipped with a 25-pin female D-Sub connector for connection to the power supply and input/output signals. The details of the connector pins are indicated in the following table:
Figure 2 - 25-pin Female D-sub Connector
25-pin Connector 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
Shield TX RX RTS CTS nc SGND EXT BEEPER VCC+ nc OUT+ OUTVCC+ nc nc nc nc EXT TRIG+ EXT TRIGDATAIN_WAND DATAOUT OUTCLKIN CLKOUT GND earth ground transmit data receive data request to send clear to send not connected signal ground external beeper connection +5 Vdc not connected see Figure 10 +5 Vdc not connected not connected not connected not connected See Figures 6 to 9 power ground
Table 1 - TC1100 Scanner Pinout
5
Page 14
TC1100
2
RS232 Interface The TC1100 Scanner can communicate with the Host using the RS232 signals provided on the 25-pin connector. The pins are indicated in Table 1 and in the following diagram: It is always advisable to use shielded cables. The overall maximum cable length must be less than 15 m (49.2 ft). TC1100 25-pin
Host 2
TX
3
RX
TXD
4
RTS
DCD
5
CTS
DTR
7
SGND
RXD
SGND Earth Ground
Figure 3 - RS232 Interface Connection to Host
WEDGE Interface The TC1100 Scanner can communicate with the Host in a WEDGE Interface (Keyboard Emulation) using the signals provided on the 25-pin connector. The pins are indicated in Table 1 and in the following diagram: Host DATA
TC1100 25-pin
CLK
21
DATAOUT
24
CLKOUT
13
VCC+
25
GND
20
DATAIN
23
CLKIN
VCC+ GND
Keyboard VCC+ GND DATA CLK
Figure 4 - Wedge Interface Connection to Host (PC AT) and Keyboard
6
Page 15
INSTALLATION
2
PEN Emulation Interface The TC1100 Scanner can communicate with the Host in a PEN Emulation Interface using the signals provided on the 25-pin connector. The pins are indicated in Table 1 and in the following diagram: TC1100 25-pin
Host 20 WAND
DATA
13 VCC+
VCC+
25 GND
GND Earth Ground
Figure 5 – Pen Emulation Interface Connection to Host
It is always advisable to use shielded cables.
Inputs There is an input available on the TC1100 Scanner relative to the External Trigger. The pins are indicated in Table 1. These inputs are optocoupled and can be driven by both an NPN or PNP type command. The connections are indicated in the following diagrams: TC1100
Vext 30 Vdc max. EXTERNAL TRIGGER
+ 5V 18
EXT TRIG+
19
EXT TRIG-
V
Signal
Figure 6 - Input NPN Command Using External Power
Vext 30 Vdc max.
TC1100
EXTERNAL TRIGGER V
+ 5V 18
EXT TRIG+
19
EXT TRIG-
Signal
Ground
Figure 7 - Input PNP Command Using External Power
7
Page 16
TC1100
2 TC1100
EXTERNAL TRIGGER 13 Vcc 5Vdc
V
+ 5V 18 EXT TRIG+ 19 EXT TRIG25 GND
Signal Ground
Figure 8 - Input NPN Command Using TC1100 Power
TC1100
EXTERNAL TRIGGER 13 Vcc 5Vdc
V
+ 5V
Signal
18 EXT TRIG+ 19
EXT TRIG-
25
GND
Ground
Figure 9 - Input PNP Command Using TC1100 Power
Outputs There is an output available on the TC1100 Scanner relative to the Good Read event. The pins are indicated in Table 1. The connections are indicated in the following diagram:
USER INTERFACE
TC1100 11
OUT +
12
OUT -
Vext 40 Vdc max
Figure 10 - Output Connection (Good Read). Example NPN
8
Page 17
INSTALLATION
2
External Beeper Connection A beeper output signal is provided on pin 8 so that an external piezoelectric buzzer with internal oscillator can be connected for Good Read acoustic signaling. The complete circuit to be built is shown in the schematic diagram below. +5 Vdc (pin 13)
+5 Vdc (pin 13)
+ D1 (1N4148)
BZ1 (see below)
R2 (10K)
BEEPER (pin 8)
Q1 (BC337) R1 (1K)
GND (pin 25)
Figure 11 - TC1100 Scanner Beeper Connection
The following list indicates several piezoelectric buzzers that can be used in the circuitry above (part BZ1). Manufacturer
Type
MURATA DIGISOUND CITIZEN BUJEON
PKB30SPC - 2001/3001 F/TCW05 MEB-12C-5 BS12-A
See chapter 3 for Beeper Control commands.
9
Page 18
TC1100
2
2.2
TC1100 CCD SCAN ENGINE
2.2.1
Mechanical Installation
The diagram below gives the overall dimensions of the TC1100 Scan Engine and may be used for its installation.
63 [2.48]
Veritcal Optical Axis 25.7 [1.01] 12.2 [0.48]
63 [2.48] 40.5 [1.59]
2.5 [0.10]
Ø2.7 [Ø0.11] n°4 18 [0.71]
50 [1.97] mm [ in.]
2.5 [0.10]
57 [2.24]
2.5 [0.10]
28.5 [1.12]
Horizontal Optical Axis
Figure 12 - Overall Dimensions
10
60.5 [2.38]
Page 19
INSTALLATION
2.2.2
2
Electrical Connections
The TC1100 Scan Engine is equipped with two 8-pin DF13 connectors for connection to the power supply and input/output signals. The details of the connector pins are indicated in the following table:
1
J1
1
J2
Figure 13 - 8-pin Connectors
J1 1 2 3 4 5 6 7 8
SGND OUTOUT+ EXT BEEPER CTS RX RTS TX signal ground see Figure 21 beeper output signal clear to send receive data request to send transmit data
J2 1 2 3 4 5 6 7 8
VCC+ GND CLKOUT DATAOUT DATAIN_WAND CLKIN EXT TRIG+ EXT TRIG-
+5 Vdc power ground
See Figures 17 to 20
Table 2 - TC1100 Scan Engine Pinout
11