Page 9

INTRODUCTION

1

1

INTRODUCTION

The TC1100 compact CCD reader is the perfect solution for many OEM applications. It contains a built-in decoder and multi-standard interface. Due to its well-balanced mix of technical characteristics it is perfect for integration into custom equipment, setting a new standard in this product class. This Reference Manual provides connection diagrams, default parameter listing, complete application parameter settings, specific technical features and reading diagrams.

1.1 1.1.1

CONFIGURATION METHODS Configuration for RS232 Interface Users

The easiest way to configure TC1100 is by using the DL Sm@rtSet™ utility program installed from the CD included with this manual. It provides a user-friendly graphic interface that sends the command strings to the TC1100 and Help On-Line to explain configuration parameters. This manual contains the complete set of command strings for TC1100 configuration. These strings must be sent via the RS232 interface using a terminal emulator such as HyperTerminal, or with the WinHost Terminal. Configurations can also be sent as batch files. Refer to paragraph 3.2 for configuration procedures.

1.1.2

Configuration for Wedge Interface Users

For Wedge Interface Users, configuration can be accomplished either by reading the barcode labels available in this manual with the TC1100 (see chapter 4 ) or by reading the Return to RS232 Interface barcode and then configuring through the RS232 Interface. To configure TC1100 by reading the configuration barcodes:

1) Open the folded page in Appendix B with the hex-numeric table and keep it open during the device configuration.

2) Read the Enter Configuration code ONCE, available at the top of each page of configuration.

1

Page 10

TC1100

1

3) Modify the desired parameters in one or more sections following the procedures given for each group.

4) Read the Exit and Save Configuration code ONCE, available at the top of each page of configuration. Reference notes describing the operation of the more complex parameters are given in chapter 5.

1.2

STATUS INDICATORS

The reader has two LED indicators signaling several operating conditions which are described in the tables below.

Led2

Led1

TC1100 Scan Engine

TC1100 Scanner

POWER UP POWER ON / LED2

Meaning

ON

Power supply ON

OFF

Power supply OFF

DATA ENTRY GOOD READ / LED1 Meaning

2

ON

Good read (LED1 will remain ON until status changes)

OFF

Miss read

Page 11

INTRODUCTION

1.3

1

AVAILABLE MODELS

The TC1100 reader is available in models that differ in regard to the following characteristics: •

Barcode type

•

Enclosure

The following models are therefore available: •

TC1100-0100 = CCD Scan Engine for linear codes

•

TC1100-0200 = CCD Scan Engine for linear and PDF417 codes

•

TC1100-1100 = CCD Scanner for linear codes

•

TC1100-1200 = CCD Scanner for linear and PDF417 codes

3