The text of a manual · part 44 of 48
QuickScan QD2100 General Purpose Corded Handheld Linear Imager Bar Code Reader Product Reference Guide: LED and Beeper Indications
Pages 361 to 364 of 388, from QuickScan QD2100 General Purpose Corded Handheld Linear Imager Bar Code Reader Product Reference Guide
The original document is the PDF (11 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic QD2110 and Datalogic QD2130
Page 361
Appendix C LED and Beeper Indications The imager’s beeper sounds and its LED illuminates to indicate various functions or errors on the imager. An optional “Green Spot” also performs useful functions. The tables below list these indications. One exception to the behaviors listed in the tables is that the imager’s functions are programmable, and may or may not be turned on. For example, certain indications, such as the power-up beep can be disabled using programming barcode labels.
Product Reference Guide
351
Page 362
LED and Beeper Indications INDICATION
DESCRIPTION
LED
BEEPER Imager beeps four times at highest frequency and volume upon powerup.
Power-up Beep
The imager is in the process of powering-up.
Good Read Beep
A label has been successfully scanned by the imager.
LED behavior for this indication is configurable via the feature “Good Read: When to Indicate”
The imager will beep once at current frequency, volume, mono/bitonal setting and duration upon a successful label scan.
ROM Failure
There is an error in the imager's software/programming
Flashes
Imager sounds one error beep at highest volume.
Limited Scanning Label Read
Indicates that a host connection is not established when the IBM or USB interface is enabled.
N/A
Imager 'chirps' six times at the highest frequency and current volume.
Imager Active Mode
The imager is active and ready to scan.
The LED is lit steadilya
N/A
Imager Disabled
The imager has been disabled by the host.
The LED blinks continuously
N/A
Green Spot is on continuously
While in Stand Mode or Trigger Object Sense mode the green spot shall be on while in stand watch state.
N/A
N/A
Green Spota flashes momentarily
Upon successful read of a label, the software shall turn the green spot on for the time specified by the configured value.
N/A
N/A
Programming Mode - The following indications ONLY occur when the imager is in Programming Mode. Label Programming Mode Entry
A valid programming label has been scanned.
Label Programming Mode Rejection of Label
LED blinks continuously
Imager sounds four low frequency beeps.
A label has been rejected.
N/A
Imager sounds three times at lowest frequency & current volume.
Label Programming Mode Acceptance of Partial Label
In cases where multiple labels must be scanned to program one feature, this indication acknowledges each portion as it is successfully scanned.
N/A
Imager sounds one short beep at highest frequency & current volume.
Label Programming Mode Acceptance of Programming
Configuration option(s) have been successfully programmed via labels and the imager has exited Programming Mode.
N/A
Imager sounds one high frequency beep and 4 low frequency beeps followed by reset beeps.
Label Programming Mode Cancel Item Entry
Cancel label has been scanned.
N/A
Imager sounds two times at low frequency and current volume.
a.
352
Except when in sleep mode or when a Good Read LED Duration other than 00 is selected
QuickScan® QD2100
Page 363
Error Codes
Error Codes Upon startup, if the imager sounds a long tone, this means the imager has not passed its automatic Selftest and has entered FRU1 isolation mode. If the imager is reset, the sequence will be repeated. The following table describes the LED flashes/beep codes associated with an error found. NUMBER OF LED FLASHES/BEEPS
ERROR
1
Configuration
2
Interface PCB
4
Imager Module
5
[Reserved]
6
Digital PCB
14
CPLD/Code Mismatch
CORRECTIVE ACTION
Contact Helpdesk for assistance
1. Field Replaceable Unit (FRU)
Product Reference Guide
353
Page 364
NOTES
354
QuickScan® QD2100