Page 347
Appendix B Standard Defaults The most common configuration settings are listed in the “Default” column of Table 47. The settings in this table are as applied to a standard RS-232 interface. See Table 48 for a listing of default exceptions to this list as appled to other interface types. Page references are also provided for feature descriptions and programming barcodes for each parameter. A column has also been provided for recording of your preferred default settings for these same configurable features. Table 47. Standard Defaults Parameter
Default
Your Setting
Page Number
General Features
Double Read Timeout
0.4 Second
17
Label Gone Timeout
160 ms
19
Power On Alert
4 Beeps
21
After Decode
22
Good Read Beep Type
Mono
23
Good Read Beep Frequency
Medium
24
Good Read Beep Length
80 ms
24
Good Read Beep Volume
High
26
Good Read LED Duration
LED on until next trigger pull
27
Scan Mode
Trigger Single
29
Stand Mode Triggered Timeout
0.5 Seconds
31
Scanning Active Time
5 Seconds
33
Flash On Time
1 Second
35
Flash Off Time
600 ms
37
Stand Mode Sensitivity
Medium
39
Green Spot Duration
300 ms
40
Good Read: When to Indicate
Product Reference Guide
337
Page 348
Parameter
Default
Your Setting
Page Number
RS-232
Baud Rate
9600
41
Data Bits
8 Data Bits
43
Stop Bits
1 Stop Bit
44
Parity
None
45
Handshaking Control
Disable
46
Intercharacter Delay
No Delay
48
Beep On ASCII BEL
Disable
50
Beep On Not on File
Enable
50
ACK Character
‘ACK’
52
NAK Character
‘NAK’
54
ACK NAK Timeout Value
600 ms
56
ACK NAK Retry Count
3 Retries
58
ACK NAK Error Handling
Ignore Errors Detected
60
Enable
61
Disable Character
‘D’
62
Enable Character
‘E’
64
Country Mode
U.S. Keyboard
68
Caps Lock State
Caps Lock OFF
71
Numlock
Numlock Key Unchanged
71
Send Control Characters
Disable
72
Intercode Delay
100 ms
77
Intercharacter Delay
No Delay
75
Intercode Delay
100 ms
78
USB Keyboard Speed
1 ms
79
Handheld Scanner
82
RS-232/USB-COM
Indicate Transmission Failure
Keyboard Wedge
USB-OEM
USB-OEM Device Usage
338
QuickScan® QD2100
Page 349
Parameter
USB-OEM Interface Options
Default
Your Setting
Page Number
Ignore
83
6
86
IBM Std Format
89
Ignore
90
Wand Idle State
High
91
Wand Polarity
QZ & Spaces High, Bars Low
92
660ms
93
No Conversion
94
Disable
95
No Global Prefix Global Suffix = 0x0D (CR)
98
Global AIM ID
Disable
100
Label ID Control
Disable
108
Case Conversion
Disable
117
No Char Conversion
118
Enable only UPC/ EAN
123
UPC-A Enable/Disable
Enable
124
UPC-A Check Character Transmission
Enable
124
Don’t Expand
125
Transmit
125
UPC-A Minimum Reads
1
143
In-Store Minimum Reads
2
126
IBM 46XX
46xx Number of Host Resets Transmit Labels in Code 39 Format IBM 46XX Interface Options Wand Emulation
Wand Signal Speed Wand Label Symbology Conversion Wand Transmit Noise Data Editing
Global Prefix/Suffix
Character Conversion Symbologies
Coupon Control
UPC-A
Expand UPC-A to EAN-13 UPC-A Number System Character Transmission
UPC-E
Product Reference Guide
339
Page 350
Parameter
Default
Your Setting
Page Number
UPC-E Enable/Disable
Enable
127
UPC-E Check Character Transmission
Send
127
Expand UPC-E to EAN-13
Don’t Expand
128
Expand UPC-E to UPC-A
Don’t Expand
128
Transmit
129
2
130
Disable
131
EAN 13 Enable/Disable
Enable
132
EAN 13 Check Character Transmission
Send
132
EAN-13 Flag 1 Character
Transmit
133
EAN-13 ISBN Conversion
Disable
134
ISSN Enable/Disable
Disable
134
1
135
EAN 8 Enable/Disable
Enable
136
EAN 8 Check Character Transmission
Send
136
Expand EAN 8 to EAN 13
Disable
137
EAN 8 Minimum Reads
1
138
2
139
UPC/EAN Correlation
Disable
141
UPC/EAN Price Weight Check
Disable
142
Disable P2, P5 and P8
144
Optional Add-On Timer
70 ms
146
Optional GS1-128 Add-On Timer
Disable
149
2
152
UPC-E Number System Character Transmission UPC-E Minimum Reads
GTIN GTIN Formatting
EAN 13
EAN 13 Minimum Reads
EAN 8
UPC/EAN Global Settings UPC/EAN Decoding Level
Add-Ons Optional Add-ons
P2 Add-Ons Minimum Reads
340
QuickScan® QD2100
Page 351
Parameter
Default
Your Setting
Page Number
P5 Add-Ons Minimum Reads
1
153
GS1-128 Add-Ons Minimum Reads
1
154
GS1 DataBar Omnidirectional Enable/ Disable
Disable
155
GS1 DataBar Omnidirectional GS1-128 Emulation
Disable
155
GS1 DataBar Omnidirectional Minimum Reads
1
156
GS1 DataBar Expanded Enable/Disable
Disable
157
GS1 DataBar Expanded GS1-128 Emulation
Disable
157
GS1 DataBar Expanded Minimum Reads
1
158
GS1 DataBar Expanded Length Control
Variable
159
GS1 DataBar Expanded Set Length 1
1
160
GS1 DataBar Expanded Set Length 2
74
162
GS1 DataBar Limited Enable/Disable
Disable
164
GS1 DataBar Limited GS1-128 Emulation
Disable
164
GS1 DataBar Limited Minimum Reads
1
165
Code 39 Enable/Disable
Enable
166
Code 39 Check Character Calculation
Calculate
167
Code 39 Check Character Transmission
Send
168
Code 39 Start/Stop Character Transmission
Don’t Transmit
168
Code 39 Full ASCII
Disable
169
Code 39 Quiet Zones
Auto
170
Code 39 Minimum Reads
2
171
Code 39 Decoding Level
3
172
GS1 DataBar Omnidirectional
GS1 DataBar Expanded
GS1 DataBar Limited
Code 39
Product Reference Guide
341
Page 352
Parameter
Default
Your Setting
Page Number
Code 39 Length Control
Variable
174
Code 39 Set Length 1
2
175
Code 39 Set Length 2
50
177
Code 39 Interdigit Ratio
4
179
Code 39 Character Correlation
Disable
181
Code 39 Stitching
Enable
182
Disable
183
3
183
Code 32 Check Character Transmission
Don’t Send
184
Code 32 Start/Stop Character Transmission
Don’t Transmit
184
Disable
185
Enable
185
Don’t Expand
186
Code 128 Check Character Transmission
Send
186
Code 128 Quiet Zones
Auto
189
Code 128 Minimum Reads
1
190
Code 128 Decoding Level
3
191
Code 128 Length Control
Variable
193
Code 128 Set Length 1
1
194
Code 128 Set Length 2
80
196
Code 128 Character Correlation
Disable
198
Code 128 Stitching
Enable
199
Transmit in Code 128 Data Format
200
Code 32 Code 32 Enable/Disable Code 32 Feature Setting Exceptions
Code 39 CIP Code 39 CIP Enable/Disable
Code 128 Code 128 Enable/Disable Expand Code 128 to Code 39
GS1-128 GS1-128 Enable
Interleaved 2 of 5
342
QuickScan® QD2100
Page 353
Parameter
Default
Your Setting
Page Number
I 2 of 5 Enable/Disable
Disable
201
I 2 of 5 Check Character Calculation
Disable
202
I 2 of 5 Check Character Transmission
Send
203
I 2 of 5 Minimum Reads
2
216
2 of 5 Decoding Level
3
205
I 2 of 5 Length Control
Variable
207
I 2 of 5 Set Length 1
12
208
I 2 of 5 Set Length 2
100
210
I 2 of 5 Character Correlation
Disable
212
I 2 of 5 Stitching
Disable
213
Disable
214
Datalogic 2 of 5 Enable/Disable
Enable
214
Datalogic 2 of 5 Check Character Calculation
Disable
215
Datalogic 2 of 5 Minimum Reads
2
216
Datalogic 2 of 5 Length Control
Variable
217
Datalogic 2 of 5 Set Length 1
12
218
Datalogic 2 of 5 Set Length 2
100
220
Datalogic 2 of 5 Character Correlation
Disable
224
Datalogic 2 of 5 Stitching
Disable
225
Disable
226
Codabar Check Character Calculation
Don’t Calculate
227
Codabar Check Character Transmission
Send
228
Codabar Start/Stop Character Transmission
Transmit
228
Codabar Start/Stop Character Set abcd/abcd
229
Codabar Start/Stop Character Match
Don’t Require Match
230
Interleaved 2 of 5 CIP Interleaved 2 of 5 CIP HR Enable/Disable
Datalogic 2 of 5
Codabar Codabar Enable/Disable
Product Reference Guide
343
Page 354
Parameter
Default
Your Setting
Page Number
Codabar Quiet Zones
Auto
231
Codabar Minimum Reads
2
232
Codabar Decoding Level
3
233
Codabar Length Control
Variable
235
Codabar Set Length 1
3
236
Codabar Set Length 2
50
238
Codabar Interdigit Ratio
4
240
Codabar Character Correlation
Disable
242
Codabar Stitching
Disable
243
ABC Codabar Enable/Disable
Disable
244
ABC Codabar Concatenation Mode
Static
244
ABC Codabar Dynamic Concatenation Timeout
200mS
245
ABC Codabar Force Concatenation
Disable
246
Disable
247
1
247
Code 11 Check Character Calculation
Check C and K
248
Code 11 Check Character Transmission
Send
249
Code 11 Minimum Reads
2
250
Code 11 Length Control
Variable
251
Code 11 Set Length 1
4
252
Code 11 Set Length 2
50
254
Code 11 Interdigit Ratio
4
256
Code 11 Decoding Level
3
258
Code 11 Character Correlation
Disable
260
Code 11 Stitching
Disable
261
Disable
262
ABC Codabar
Code 11 Code 11 Enable/Disable
Standard 2 of 5 Standard 2 of 5 Enable/Disable
344
QuickScan® QD2100
Page 355
Parameter
Default
Your Setting
Page Number
Standard 2 of 5 Check Character Calculation
Disable
263
Standard 2 of 5 Check Character Transmission
Send
263
Standard 2 of 5 Minimum Reads
2
264
Standard 2 of 5 Decoding Level
3
264
Standard 2 of 5 Length Control
Variable
265
Standard 2 of 5 Set Length 1
8
266
Standard 2 of 5 Set Length 2
50
268
Standard 2 of 5 Character Correlation
Disable
270
Standard 2 of 5 Stitching
Disable
271
Industrial 2 of 5 Enable/Disable
Disable
272
Industrial 2 of 5 Check Character Calculation
Disable
272
Industrial 2 of 5 Check Character Transmission
Enable
273
Industrial 2 of 5 Length Control
Variable
274
Industrial 2 of 5 Set Length 1
1 Character
275
Industrial 2 of 5 Set Length 2
50 Characters
277
Industrial 2 of 5 Minimum Reads
1 Read
279
Industrial 2 of 5 Stitching
Disable
280
Industrial 2 of 5 Character Correlation
Disable
280
IATA Enable/Disable
Disable
281
IATA Check Character Transmission
Enable
281
ISBT 128 Concatenation
Disable
282
ISBT 128 Concatenation Mode
Disable
283
ISBT 128 Dynamic Concatenation Timeout
200ms
284
ISBT 128 Force Concatenation
Enable
285
Industrial 2 of 5
IATA
ISBT 128
Product Reference Guide
345
Page 356
Parameter
ISBT 128 Advanced Concatenation Options
Default
Your Setting
Page Number
Disable
285
Disable
286
MSI Check Character Calculation
Enable Mod10
287
MSI Check Character Transmission
Enable
288
MSI Length Control
Variable
288
MSI Set Length 1
1 Character
289
MSI Set Length 2
50 Characters
291
MSI Minimum Reads
4 Reads
293
MSI Decoding Level
Level 3
294
Disable
296
Plessey Check Character Calculation
Enable Plessey Std. Check Char. Verif.
297
Plessey Check Character Transmission
Enable
298
PLessey Length Control
Variable
298
Plessey Set Length 1
1 Character
299
Plessey Set Length 2
50 Characters
301
Plessey Minimum Reads
4 Reads
303
Plessey Decoding Level
Level 3
304
Plessey Stitching
Disable
305
Plessey Character Correlation
Disable
306
Code 93 Enable/Disable
Disable
306
Code 93 Check Character Calculation
Disable
307
Code 93 Check Character Transmission
Enable
308
Code 93 Length Control
Variable
308
Code 93 Set Length 1
1 Character
309
Code 93 Set Length 2
50 Characters
311
Code 93 Minimum Reads
1 Read
313
MSI MSI Enable/Disable
Plessey Plessey Enable/Disable
Code 93
346
QuickScan® QD2100
Page 357
Parameter
Default
Your Setting
Page Number
Code 93 Decoding Level
Level 3
314
Code 93 Quiet Zones
Auto
316
Code 93 Stitching
Enable
317
Code 93 Character Correlation
Enable
317
Codablock F Enable/Disable
Disable
318
Codablock F EAN Enable/Disable
Disable
319
Enable Check C
319
Codablock F Length Control
Variable
320
Codablock F Set Length 1
3 Characters
321
Codablock F Set Length 2
100 Characters
323
Code 4 Enable/Disable
Disable
325
Code 4 Check Character Transmission
Enable
326
Code 4 Hex to Decimal Conversion
Enable
326
Code 5 Enable/Disable
Disable
327
Code 5 Check Character Transmission
Enable
328
Code 5 Hex to Decimal Conversion
Enable
328
Codablock F
Codablock F AIM Check
Code 4
Code 5
Code 4 and Code 5 Common Configuration Items Code 4 and 5 Decoding Level
3
329
Code 4 and Code 5 Minimum Reads
1
331
Disable
332
Follett 2 of 5 Follett 2 of 5 Enable/Disable
Product Reference Guide
347
Page 358
Default Exceptions Table 47 lists standard default settings as applied to a standard RS-232 interface. Table 48 provides a listing of default exceptions to that list as applied to the other interface types. Table 48. Default Exceptions by Interface Type Parameter
Default Excption
Interfaces: IBM 46XX Port 5B, IBM 46XX Port 9B, USB-OEM Global Suffix Double Read Timeout
No Global Suffix 500 msec
Interfaces: All Keyboard Wedge, USB Keyboard No unique settings Interface: RS232-WN
348
Expand UPC-A to EAN-13
Enable
UPC-E Check Character Transmission
Disable
Parity
Odd Parity
Handshaking Control
RTS/CTS
Transmission Label ID Code
Prefix
GS1-128 AIM ID
Disable
UPCE Label ID Character(s)
C
EAN 8 Label ID Character(s)
B
EAN 13 Label ID Character(s)
A
Code ISBN Label ID Character(s)
A
Code 39 Label ID Character(s)
M
Interelaved 2of5 Label ID Character(s)
I
Code Standard 2/5 Label ID Character(s)
H
Codabar Label ID Character(s)
N
Code 128 Label ID Character(s)
K
GS1-128 Label ID Character(s)
P
Datalogic 2 of 5 Label ID Character(s)
H
ISBT 128 Label ID Character(s)
K
UPCE P2 Label ID Character(s)
C
UPCE/P5 Label ID Character(s)
C
UPCE/GS1-128 Label ID Character(s)
C
QuickScan® QD2100
Page 359
Default Exceptions
Parameter
Default Excption
EAN8/P2 Label ID Character(s)
B
EAN8/P5 Label ID Character(s)
B
EAN8/GS1-128 Label ID Character(s)
B
EAN13/P2 Label ID Character(s)
A
EAN13/P5 Label ID Character(s)
A
EAN13/GS1-128 Label ID Character(s)
A
GS1 DataBar 14 (Omnidirectional) Label ID Character(s)
E
GS1 DataBar Expanded Label ID Character(s)
E
GS1 DataBar Limited Label ID Character(s)
E
Character Conversion
CR to `
Interface: RS232-OPOS Baud Rate
115200 Baud
Transmission Label ID Code
Prefix
GS1-128 AIM ID
Disable
UPCA Label ID Character(s)
C
UPCE Label ID Character(s)
D
EAN 8 Label ID Character(s)
A
EAN 13 Label ID Character(s)
B
Code ISBN Label ID Character(s)
@
Code 39 Label ID Character(s)
V
Code 32 Label ID Character(s)
X
Interelaved 2of5 Label ID Character(s)
N
Code Standard 2/5 Label ID Character(s)
P
Codabar Label ID Character(s)
R
Code 11 Label ID Character(s)
b
Code 128 Label ID Character(s)
T
GS1-128 Label ID Character(s)
k
UPCA/P2 Label ID Character(s)
F
UPCA/P5 Label ID Character(s)
G
UPCA/GS1-128 Label ID Character(s)
Q
UPCE P2 Label ID Character(s)
H
Product Reference Guide
349
Page 360
Parameter
350
Default Excption
UPCE/P5 Label ID Character(s)
I
EAN8/P2 Label ID Character(s)
J
EAN8/P5 Label ID Character(s)
K
EAN8/GS1-128 Label ID Character(s)
*
EAN13/P2 Label ID Character(s)
L
EAN13/P5 Label ID Character(s)
M
EAN13/GS1-128 Label ID Character(s)
#
GS1 DataBar 14 (Omnidirectional) Label ID Character(s)
u
GS1 DataBar Expanded Label ID Character(s)
t
GS1 DataBar Limited Label ID Character(s)
v
GTIN W/o Add on Label ID Character(s)
$A
GTIN Addon 2 Label ID Character(s)
$B
GTIN Add on 5 Label ID Character(s)
$C
GTIN Add on 8 Label ID Character(s)
$D