Page 347

Appendix B Standard Defaults The most common configuration settings are listed in the “Default” column of Table 47. The settings in this table are as applied to a standard RS-232 interface. See Table 48 for a listing of default exceptions to this list as appled to other interface types. Page references are also provided for feature descriptions and programming barcodes for each parameter. A column has also been provided for recording of your preferred default settings for these same configurable features. Table 47. Standard Defaults Parameter

Default

Your Setting

Page Number

General Features

Double Read Timeout

0.4 Second

17

Label Gone Timeout

160 ms

19

Power On Alert

4 Beeps

21

After Decode

22

Good Read Beep Type

Mono

23

Good Read Beep Frequency

Medium

24

Good Read Beep Length

80 ms

24

Good Read Beep Volume

High

26

Good Read LED Duration

LED on until next trigger pull

27

Scan Mode

Trigger Single

29

Stand Mode Triggered Timeout

0.5 Seconds

31

Scanning Active Time

5 Seconds

33

Flash On Time

1 Second

35

Flash Off Time

600 ms

37

Stand Mode Sensitivity

Medium

39

Green Spot Duration

300 ms

40

Good Read: When to Indicate

Product Reference Guide

337

Page 348

Parameter

Default

Your Setting

Page Number

RS-232

Baud Rate

9600

41

Data Bits

8 Data Bits

43

Stop Bits

1 Stop Bit

44

Parity

None

45

Handshaking Control

Disable

46

Intercharacter Delay

No Delay

48

Beep On ASCII BEL

Disable

50

Beep On Not on File

Enable

50

ACK Character

‘ACK’

52

NAK Character

‘NAK’

54

ACK NAK Timeout Value

600 ms

56

ACK NAK Retry Count

3 Retries

58

ACK NAK Error Handling

Ignore Errors Detected

60

Enable

61

Disable Character

‘D’

62

Enable Character

‘E’

64

Country Mode

U.S. Keyboard

68

Caps Lock State

Caps Lock OFF

71

Numlock

Numlock Key Unchanged

71

Send Control Characters

Disable

72

Intercode Delay

100 ms

77

Intercharacter Delay

No Delay

75

Intercode Delay

100 ms

78

USB Keyboard Speed

1 ms

79

Handheld Scanner

82

RS-232/USB-COM

Indicate Transmission Failure

Keyboard Wedge

USB-OEM

USB-OEM Device Usage

338

QuickScan® QD2100

Page 349

Parameter

USB-OEM Interface Options

Default

Your Setting

Page Number

Ignore

83

6

86

IBM Std Format

89

Ignore

90

Wand Idle State

High

91

Wand Polarity

QZ & Spaces High, Bars Low

92

660ms

93

No Conversion

94

Disable

95

No Global Prefix Global Suffix = 0x0D (CR)

98

Global AIM ID

Disable

100

Label ID Control

Disable

108

Case Conversion

Disable

117

No Char Conversion

118

Enable only UPC/ EAN

123

UPC-A Enable/Disable

Enable

124

UPC-A Check Character Transmission

Enable

124

Don’t Expand

125

Transmit

125

UPC-A Minimum Reads

1

143

In-Store Minimum Reads

2

126

IBM 46XX

46xx Number of Host Resets Transmit Labels in Code 39 Format IBM 46XX Interface Options Wand Emulation

Wand Signal Speed Wand Label Symbology Conversion Wand Transmit Noise Data Editing

Global Prefix/Suffix

Character Conversion Symbologies

Coupon Control

UPC-A

Expand UPC-A to EAN-13 UPC-A Number System Character Transmission

UPC-E

Product Reference Guide

339

Page 350

Parameter

Default

Your Setting

Page Number

UPC-E Enable/Disable

Enable

127

UPC-E Check Character Transmission

Send

127

Expand UPC-E to EAN-13

Don’t Expand

128

Expand UPC-E to UPC-A

Don’t Expand

128

Transmit

129

2

130

Disable

131

EAN 13 Enable/Disable

Enable

132

EAN 13 Check Character Transmission

Send

132

EAN-13 Flag 1 Character

Transmit

133

EAN-13 ISBN Conversion

Disable

134

ISSN Enable/Disable

Disable

134

1

135

EAN 8 Enable/Disable

Enable

136

EAN 8 Check Character Transmission

Send

136

Expand EAN 8 to EAN 13

Disable

137

EAN 8 Minimum Reads

1

138

2

139

UPC/EAN Correlation

Disable

141

UPC/EAN Price Weight Check

Disable

142

Disable P2, P5 and P8

144

Optional Add-On Timer

70 ms

146

Optional GS1-128 Add-On Timer

Disable

149

2

152

UPC-E Number System Character Transmission UPC-E Minimum Reads

GTIN GTIN Formatting

EAN 13

EAN 13 Minimum Reads

EAN 8

UPC/EAN Global Settings UPC/EAN Decoding Level

Add-Ons Optional Add-ons

P2 Add-Ons Minimum Reads

340

QuickScan® QD2100

Page 351

Parameter

Default

Your Setting

Page Number

P5 Add-Ons Minimum Reads

1

153

GS1-128 Add-Ons Minimum Reads

1

154

GS1 DataBar Omnidirectional Enable/ Disable

Disable

155

GS1 DataBar Omnidirectional GS1-128 Emulation

Disable

155

GS1 DataBar Omnidirectional Minimum Reads

1

156

GS1 DataBar Expanded Enable/Disable

Disable

157

GS1 DataBar Expanded GS1-128 Emulation

Disable

157

GS1 DataBar Expanded Minimum Reads

1

158

GS1 DataBar Expanded Length Control

Variable

159

GS1 DataBar Expanded Set Length 1

1

160

GS1 DataBar Expanded Set Length 2

74

162

GS1 DataBar Limited Enable/Disable

Disable

164

GS1 DataBar Limited GS1-128 Emulation

Disable

164

GS1 DataBar Limited Minimum Reads

1

165

Code 39 Enable/Disable

Enable

166

Code 39 Check Character Calculation

Calculate

167

Code 39 Check Character Transmission

Send

168

Code 39 Start/Stop Character Transmission

Don’t Transmit

168

Code 39 Full ASCII

Disable

169

Code 39 Quiet Zones

Auto

170

Code 39 Minimum Reads

2

171

Code 39 Decoding Level

3

172

GS1 DataBar Omnidirectional

GS1 DataBar Expanded

GS1 DataBar Limited

Code 39

Product Reference Guide

341

Page 352

Parameter

Default

Your Setting

Page Number

Code 39 Length Control

Variable

174

Code 39 Set Length 1

2

175

Code 39 Set Length 2

50

177

Code 39 Interdigit Ratio

4

179

Code 39 Character Correlation

Disable

181

Code 39 Stitching

Enable

182

Disable

183

3

183

Code 32 Check Character Transmission

Don’t Send

184

Code 32 Start/Stop Character Transmission

Don’t Transmit

184

Disable

185

Enable

185

Don’t Expand

186

Code 128 Check Character Transmission

Send

186

Code 128 Quiet Zones

Auto

189

Code 128 Minimum Reads

1

190

Code 128 Decoding Level

3

191

Code 128 Length Control

Variable

193

Code 128 Set Length 1

1

194

Code 128 Set Length 2

80

196

Code 128 Character Correlation

Disable

198

Code 128 Stitching

Enable

199

Transmit in Code 128 Data Format

200

Code 32 Code 32 Enable/Disable Code 32 Feature Setting Exceptions

Code 39 CIP Code 39 CIP Enable/Disable

Code 128 Code 128 Enable/Disable Expand Code 128 to Code 39

GS1-128 GS1-128 Enable

Interleaved 2 of 5

342

QuickScan® QD2100

Page 353

Parameter

Default

Your Setting

Page Number

I 2 of 5 Enable/Disable

Disable

201

I 2 of 5 Check Character Calculation

Disable

202

I 2 of 5 Check Character Transmission

Send

203

I 2 of 5 Minimum Reads

2

216

2 of 5 Decoding Level

3

205

I 2 of 5 Length Control

Variable

207

I 2 of 5 Set Length 1

12

208

I 2 of 5 Set Length 2

100

210

I 2 of 5 Character Correlation

Disable

212

I 2 of 5 Stitching

Disable

213

Disable

214

Datalogic 2 of 5 Enable/Disable

Enable

214

Datalogic 2 of 5 Check Character Calculation

Disable

215

Datalogic 2 of 5 Minimum Reads

2

216

Datalogic 2 of 5 Length Control

Variable

217

Datalogic 2 of 5 Set Length 1

12

218

Datalogic 2 of 5 Set Length 2

100

220

Datalogic 2 of 5 Character Correlation

Disable

224

Datalogic 2 of 5 Stitching

Disable

225

Disable

226

Codabar Check Character Calculation

Don’t Calculate

227

Codabar Check Character Transmission

Send

228

Codabar Start/Stop Character Transmission

Transmit

228

Codabar Start/Stop Character Set abcd/abcd

229

Codabar Start/Stop Character Match

Don’t Require Match

230

Interleaved 2 of 5 CIP Interleaved 2 of 5 CIP HR Enable/Disable

Datalogic 2 of 5

Codabar Codabar Enable/Disable

Product Reference Guide

343

Page 354

Parameter

Default

Your Setting

Page Number

Codabar Quiet Zones

Auto

231

Codabar Minimum Reads

2

232

Codabar Decoding Level

3

233

Codabar Length Control

Variable

235

Codabar Set Length 1

3

236

Codabar Set Length 2

50

238

Codabar Interdigit Ratio

4

240

Codabar Character Correlation

Disable

242

Codabar Stitching

Disable

243

ABC Codabar Enable/Disable

Disable

244

ABC Codabar Concatenation Mode

Static

244

ABC Codabar Dynamic Concatenation Timeout

200mS

245

ABC Codabar Force Concatenation

Disable

246

Disable

247

1

247

Code 11 Check Character Calculation

Check C and K

248

Code 11 Check Character Transmission

Send

249

Code 11 Minimum Reads

2

250

Code 11 Length Control

Variable

251

Code 11 Set Length 1

4

252

Code 11 Set Length 2

50

254

Code 11 Interdigit Ratio

4

256

Code 11 Decoding Level

3

258

Code 11 Character Correlation

Disable

260

Code 11 Stitching

Disable

261

Disable

262

ABC Codabar

Code 11 Code 11 Enable/Disable

Standard 2 of 5 Standard 2 of 5 Enable/Disable

344

QuickScan® QD2100

Page 355

Parameter

Default

Your Setting

Page Number

Standard 2 of 5 Check Character Calculation

Disable

263

Standard 2 of 5 Check Character Transmission

Send

263

Standard 2 of 5 Minimum Reads

2

264

Standard 2 of 5 Decoding Level

3

264

Standard 2 of 5 Length Control

Variable

265

Standard 2 of 5 Set Length 1

8

266

Standard 2 of 5 Set Length 2

50

268

Standard 2 of 5 Character Correlation

Disable

270

Standard 2 of 5 Stitching

Disable

271

Industrial 2 of 5 Enable/Disable

Disable

272

Industrial 2 of 5 Check Character Calculation

Disable

272

Industrial 2 of 5 Check Character Transmission

Enable

273

Industrial 2 of 5 Length Control

Variable

274

Industrial 2 of 5 Set Length 1

1 Character

275

Industrial 2 of 5 Set Length 2

50 Characters

277

Industrial 2 of 5 Minimum Reads

1 Read

279

Industrial 2 of 5 Stitching

Disable

280

Industrial 2 of 5 Character Correlation

Disable

280

IATA Enable/Disable

Disable

281

IATA Check Character Transmission

Enable

281

ISBT 128 Concatenation

Disable

282

ISBT 128 Concatenation Mode

Disable

283

ISBT 128 Dynamic Concatenation Timeout

200ms

284

ISBT 128 Force Concatenation

Enable

285

Industrial 2 of 5

IATA

ISBT 128

Product Reference Guide

345

Page 356

Parameter

ISBT 128 Advanced Concatenation Options

Default

Your Setting

Page Number

Disable

285

Disable

286

MSI Check Character Calculation

Enable Mod10

287

MSI Check Character Transmission

Enable

288

MSI Length Control

Variable

288

MSI Set Length 1

1 Character

289

MSI Set Length 2

50 Characters

291

MSI Minimum Reads

4 Reads

293

MSI Decoding Level

Level 3

294

Disable

296

Plessey Check Character Calculation

Enable Plessey Std. Check Char. Verif.

297

Plessey Check Character Transmission

Enable

298

PLessey Length Control

Variable

298

Plessey Set Length 1

1 Character

299

Plessey Set Length 2

50 Characters

301

Plessey Minimum Reads

4 Reads

303

Plessey Decoding Level

Level 3

304

Plessey Stitching

Disable

305

Plessey Character Correlation

Disable

306

Code 93 Enable/Disable

Disable

306

Code 93 Check Character Calculation

Disable

307

Code 93 Check Character Transmission

Enable

308

Code 93 Length Control

Variable

308

Code 93 Set Length 1

1 Character

309

Code 93 Set Length 2

50 Characters

311

Code 93 Minimum Reads

1 Read

313

MSI MSI Enable/Disable

Plessey Plessey Enable/Disable

Code 93

346

QuickScan® QD2100

Page 357

Parameter

Default

Your Setting

Page Number

Code 93 Decoding Level

Level 3

314

Code 93 Quiet Zones

Auto

316

Code 93 Stitching

Enable

317

Code 93 Character Correlation

Enable

317

Codablock F Enable/Disable

Disable

318

Codablock F EAN Enable/Disable

Disable

319

Enable Check C

319

Codablock F Length Control

Variable

320

Codablock F Set Length 1

3 Characters

321

Codablock F Set Length 2

100 Characters

323

Code 4 Enable/Disable

Disable

325

Code 4 Check Character Transmission

Enable

326

Code 4 Hex to Decimal Conversion

Enable

326

Code 5 Enable/Disable

Disable

327

Code 5 Check Character Transmission

Enable

328

Code 5 Hex to Decimal Conversion

Enable

328

Codablock F

Codablock F AIM Check

Code 4

Code 5

Code 4 and Code 5 Common Configuration Items Code 4 and 5 Decoding Level

3

329

Code 4 and Code 5 Minimum Reads

1

331

Disable

332

Follett 2 of 5 Follett 2 of 5 Enable/Disable

Product Reference Guide

347

Page 358

Default Exceptions Table 47 lists standard default settings as applied to a standard RS-232 interface. Table 48 provides a listing of default exceptions to that list as applied to the other interface types. Table 48. Default Exceptions by Interface Type Parameter

Default Excption

Interfaces: IBM 46XX Port 5B, IBM 46XX Port 9B, USB-OEM Global Suffix Double Read Timeout

No Global Suffix 500 msec

Interfaces: All Keyboard Wedge, USB Keyboard No unique settings Interface: RS232-WN

348

Expand UPC-A to EAN-13

Enable

UPC-E Check Character Transmission

Disable

Parity

Odd Parity

Handshaking Control

RTS/CTS

Transmission Label ID Code

Prefix

GS1-128 AIM ID

Disable

UPCE Label ID Character(s)

C

EAN 8 Label ID Character(s)

B

EAN 13 Label ID Character(s)

A

Code ISBN Label ID Character(s)

A

Code 39 Label ID Character(s)

M

Interelaved 2of5 Label ID Character(s)

I

Code Standard 2/5 Label ID Character(s)

H

Codabar Label ID Character(s)

N

Code 128 Label ID Character(s)

K

GS1-128 Label ID Character(s)

P

Datalogic 2 of 5 Label ID Character(s)

H

ISBT 128 Label ID Character(s)

K

UPCE P2 Label ID Character(s)

C

UPCE/P5 Label ID Character(s)

C

UPCE/GS1-128 Label ID Character(s)

C

QuickScan® QD2100

Page 359

Default Exceptions

Parameter

Default Excption

EAN8/P2 Label ID Character(s)

B

EAN8/P5 Label ID Character(s)

B

EAN8/GS1-128 Label ID Character(s)

B

EAN13/P2 Label ID Character(s)

A

EAN13/P5 Label ID Character(s)

A

EAN13/GS1-128 Label ID Character(s)

A

GS1 DataBar 14 (Omnidirectional) Label ID Character(s)

E

GS1 DataBar Expanded Label ID Character(s)

E

GS1 DataBar Limited Label ID Character(s)

E

Character Conversion

CR to `

Interface: RS232-OPOS Baud Rate

115200 Baud

Transmission Label ID Code

Prefix

GS1-128 AIM ID

Disable

UPCA Label ID Character(s)

C

UPCE Label ID Character(s)

D

EAN 8 Label ID Character(s)

A

EAN 13 Label ID Character(s)

B

Code ISBN Label ID Character(s)

@

Code 39 Label ID Character(s)

V

Code 32 Label ID Character(s)

X

Interelaved 2of5 Label ID Character(s)

N

Code Standard 2/5 Label ID Character(s)

P

Codabar Label ID Character(s)

R

Code 11 Label ID Character(s)

b

Code 128 Label ID Character(s)

T

GS1-128 Label ID Character(s)

k

UPCA/P2 Label ID Character(s)

F

UPCA/P5 Label ID Character(s)

G

UPCA/GS1-128 Label ID Character(s)

Q

UPCE P2 Label ID Character(s)

H

Product Reference Guide

349

Page 360

Parameter

350

Default Excption

UPCE/P5 Label ID Character(s)

I

EAN8/P2 Label ID Character(s)

J

EAN8/P5 Label ID Character(s)

K

EAN8/GS1-128 Label ID Character(s)

*

EAN13/P2 Label ID Character(s)

L

EAN13/P5 Label ID Character(s)

M

EAN13/GS1-128 Label ID Character(s)

#

GS1 DataBar 14 (Omnidirectional) Label ID Character(s)

u

GS1 DataBar Expanded Label ID Character(s)

t

GS1 DataBar Limited Label ID Character(s)

v

GTIN W/o Add on Label ID Character(s)

$A

GTIN Addon 2 Label ID Character(s)

$B

GTIN Add on 5 Label ID Character(s)

$C

GTIN Add on 8 Label ID Character(s)

$D