The text of a manual · part 40 of 48
QuickScan QD2100 General Purpose Corded Handheld Linear Imager Bar Code Reader Product Reference Guide: Symbologies, pages 331 to 340
Pages 331 to 340 of 388, from QuickScan QD2100 General Purpose Corded Handheld Linear Imager Bar Code Reader Product Reference Guide
The original document is the PDF (11 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic QD2110 and Datalogic QD2130
Page 331
Codablock F
Codablock F, cont. Codablock F Set Length 1 This feature specifies one of the barcode lengths for Codablock F Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 003 to 255 characters. Follow these instructions to set this feature: 1. Determine the desired character length (from 3 to 255). Pad the number with leading zeroes to yield three digits. For example: 3 = 003, 5 = 005, 20 = 020, etc. 2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 3. Scan the barcode: SELECT CODABLOCK F LENGTH 1 SETTING. 4. Scan the appropriate three digits from the keypad in the Keypad Appendix, that represent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure. See the table below for some examples of how to set this feature. Table 43. CODABLOC K F Length 1 Setting Examples STEP
ACTION
EXAMPLES
1
Desired Setting
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODABLOCK F LENGTH 1 SETTING
4
Scan three Characters From the Keypad Appendix
5
Scan ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
003 Characters
‘0’, ‘0’ and ‘3’
007 Characters
015 Characters
050 Characters
‘0’, ‘0’ and ‘7’
‘0’,‘1’ and ‘5’
‘0’,‘5’ AND ‘0’
321
Page 332
Symbologies
Codablock F, cont. Codablock F Set Length 1, cont.
ENTER/EXIT PROGRAMMING MODE
Select Codablock F Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
322
003 = Length 1 is 3 Characters
QuickScan® QD2100
Page 333
Codablock F
Codablock F, cont. Codablock F Set Length 2 This feature specifies one of the barcode lengths for Codablock F Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and fullASCII shift characters. The length does not include start/stop characters. The length can be set from 3 to 255 characters. A setting of 0 specifies to ignore this length (only one fixed length). Follow these instructions to set this feature: 1. Determine the desired character length (from 3 to 255, or 0 to ignore this length). Pad the number with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc. 2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 3. Scan the barcode: SELECT CODABLOCK F LENGTH 2 SETTING. 4. Scan the appropriate three digits from the keypad in the Keypad Appendix that represent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake, before the last character scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure. See the table below for some examples of how to set this feature. Table 44. CODABLOCK Length 2 Setting Examples STEP
ACTION
EXAMPLES 000 (Ignore This Length)
1
Desired Setting
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODABLOCK F LENGTH 2 SETTING
4
Scan three Characters From the Keypad Appendix
5
Scan ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
‘0’, ‘0’ and ‘0’
007 Characters
015 Characters
050 Characters
‘0’, ‘0’ and ‘7’
‘0’, ‘1’ and ‘5’
‘0’, ‘5’ AND ‘0’
323
Page 334
Symbologies
Codablock F, cont. Codablock F Set Length 2, cont.
ENTER/EXIT PROGRAMMING MODE
Select Codablock F Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
324
100 = Length 2 is 100 Characters
QuickScan® QD2100
Page 335
Code 4
Code 4 The following options apply to the Code 4 symbology.
Code 4 Enable/Disable Enables/Disables ability of imager to decode Code 4 labels.
ENTER/EXIT PROGRAMMING MODE
DEFAULT Code 4 = Disable
Code 4 = Enable
Product Reference Guide
325
Page 336
Symbologies
Code 4, cont. Code 4 Check Character Transmission This feature enables/disables transmission of an optional Code 4 check character.
ENTER/EXIT PROGRAMMING MODE
Code 4 Check Character Transmission = Don’t Send
DEFAULT Code 4 Check Character Transmission = Send
Code 4 Hex to Decimal Conversion This feature enables/disables the conversion of hexidecimal label data to decimal label data.
ENTER/EXIT PROGRAMMING MODE
Code 4 Hex to Decimal Conversion = Disable
DEFAULT Code 4 Hex to Decimal Conversion = Enable
326
QuickScan® QD2100
Page 337
Code 5
Code 5 The following options apply to the Code 5 symbology.
Code 5 Enable/Disable Enables/Disables ability of imager to decode Code 5 labels.
ENTER/EXIT PROGRAMMING MODE
DEFAULT Code 5 = Disable
Code 5 = Enable
Product Reference Guide
327
Page 338
Symbologies
Code 5, cont. Code 5 Check Character Transmission This feature enables/disables transmission of an optional Code 5 check character.
ENTER/EXIT PROGRAMMING MODE
Code 5 Check Character Transmission = Don’t Send
DEFAULT Code 5 Check Character Transmission = Send
Code 5 Hex to Decimal Conversion This feature enables/disables the conversion of hexidecimal label data to decimal label data.
ENTER/EXIT PROGRAMMING MODE
Code 5 Hex to Decimal Conversion = Disable
DEFAULT Code 5 Hex to Decimal Conversion = Enable
328
QuickScan® QD2100
Page 339
Code 4 and Code 5 Common Configuration Items
Code 4 and Code 5 Common Configuration Items The following options apply to both Code 4 and Code 5 symbologies.
Code 4 and 5 Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. •
Choosing Level 1 results in a very conservative decoder at the expense of not being able to read poorly printed or damaged labels.
•
Choosing Level 5 results in a very aggressive decoder. This aggressive behavior allows decoding of poorly printed and damaged labels at the expense of increasing the likelihood of decoding errors.
•
Choosing Level 3, which is the default setting, allows the majority of product labels to be decoded.
There are many factors that determine when to change the decoding level for a particular symbology. These factors include spots, voids, non-uniform bar/space widths, damaged labels, etc. that may be experienced in some barcode labels. If there are many hard to read or damaged labels that cannot be decoded using a conservative setting, increase the decoding level to be more aggressive. If the majority of labels are very good quality labels, or there is a need to decrease the possibility of a decoder error, lower the decoding level to a more conservative level.
This configuration item applies to Code 4 and Code 5. NOTE
Product Reference Guide
329
Page 340
Symbologies
Code 4 and Code 5 Common Configuration Items, cont. Code 4 and 5 Decoding Level, cont.
ENTER/EXIT PROGRAMMING MODE
Code 4 and Code 5 Decoding Level = 1
Code 4 and Code 5 Decoding Level = 2
DEFAULT Code 4 and Code 5 Decoding Level = 3
Code 4 and Code 5 Decoding Level = 4
Code 4 and Code 5 Decoding Level = 5
330
QuickScan® QD2100