Page 321
Code 93
Code 93, cont. Code 93 Set Length 2 This feature specifies one of the barcode lengths for Code 93 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Follow these instructions to set this feature: 1. Determine the desired character length (from 1 to 50, or 0 to ignore this length). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 3. Scan the barcode: SELECT CODE 93 LENGTH 2 SETTING. 4. Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake, before the last character scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.
This completes the procedure. See the table below for some examples of how to set this feature. Table 42. CODE 93 Length 2 Setting Examples STEP
ACTION
EXAMPLES 00 (Ignore This Length)
1
Desired Setting
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODE 93 LENGTH 2 SETTING
4
Scan Two Characters From the Keypad Appendix
5
Scan ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
‘0’ and ‘0’
07 Characters
15 Characters
50 Characters
‘0’ and ‘7’
‘1’ and ‘5’
‘5’ AND ‘0’
311
Page 322
Symbologies
Code 93, cont. Code 93 Set Length 2, cont.
ENTER/EXIT PROGRAMMING MODE
Select Code 93 Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
312
50 = Length 2 is 50 Characters
QuickScan® QD2100
Page 323
Code 93
Code 93, cont. Code 93 Minimum Reads This feature specifies the minimum number of consecutive times a Code 93 label must be decoded before it is accepted as good read.
ENTER/EXIT PROGRAMMING MODE
DEFAULT Code 93 Minimum Reads = 1
Code 93 Minimum Reads = 2
Code 93 Minimum Reads = 3
Code 93 Minimum Reads = 4
Product Reference Guide
313
Page 324
Symbologies
Code 93, cont. Code 93 Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. •
Choosing Level 1 results in a very conservative decoder at the expense of not being able to read poorly printed or damaged labels.
•
Choosing Level 5 results in a very aggressive decoder. This aggressive behavior allows decoding of poorly printed and damaged labels at the expense of increasing the likelihood of decoding errors.
•
Choosing Level 3, which is the default setting, allows the majority of product labels to be decoded.
There are many factors that determine when to change the decoding level for a particular symbology. These factors include spots, voids, non-uniform bar/space widths, damaged labels, etc. that may be experienced in some barcode labels. If there are many hard to read or damaged labels that cannot be decoded using a conservative setting, increase the decoding level to be more aggressive. If the majority of labels are very good quality labels, or there is a need to decrease the possibility of a decoder error, lower the decoding level to a more conservative level.
ENTER/EXIT PROGRAMMING MODE
Code 93 Decoding Level = Disable
Code 93 Decoding Level = 1
Code 93 Decoding Level = 2
314
QuickScan® QD2100
Page 325
Code 93
Code 93, cont. Code 93 Decoding Level, cont.
DEFAULT Code 93 Decoding Level = 3
Code 93 Decoding Level = 4
Code 93 Decoding Level = 5
Product Reference Guide
315
Page 326
Symbologies
Code 93, cont. Code 93 Quiet Zones Enables/disables fixed length stitching for Code 93.
ENTER/EXIT PROGRAMMING MODE
Code 93 Quiet Zones = No Quiet Zones
Code 93 Quiet Zones = Quiet Zone on one side
Code 93 Quiet Zones = Quiet Zones on two sides
DEFAULT Code 93 Quiet Zones = Auto
Code 93 Quiet Zones = Virtual Quiet Zones on two sides
316
QuickScan® QD2100
Page 327
Code 93
Code 93, cont. Code 93 Stitching Disable/enable fixed or variable length stitching for Code 93.
ENTER/EXIT PROGRAMMING MODE
Code 93 Stitching = Disable
DEFAULT Code 93 Stitching = Enable
Code 93 Character Correlation Enables/disables Character Correlation for Code 93.
ENTER/EXIT PROGRAMMING MODE
Code 93 Character Correlation = Disable
DEFAULT Code 93 Character Correlation = Enable
Product Reference Guide
317
Page 328
Symbologies
Codablock F The following options apply to the Codablock F symbology.
Codablock F Enable/Disable Enables/Disables the ability of the imager to decode Codablock F labels.
ENTER/EXIT PROGRAMMING MODE
DEFAULT Codablock F = Disable
Codablock F = Enable
318
QuickScan® QD2100
Page 329
Codablock F
Codablock F, cont. Codablock F EAN Enable/Disable Enables/Disables the Codablock F EAN subtype (code with FNC1 in the first position).
ENTER/EXIT PROGRAMMING MODE
DEFAULT Codablock F EAN = Disable
Codablock F EAN = Enable
Codablock F AIM Check Specifies if Check Digit calculation algorithm is AIM compliant or not.
ENTER/EXIT PROGRAMMING MODE
Codablock F AIM Check = Disable
DEFAULT Codablock F AIM Check = Enable Check C
Product Reference Guide
319
Page 330
Symbologies
Codablock F, cont. Codablock F Length Control This feature specifies either variable length decoding or fixed length decoding for the Codablock F symbology. Variable Length, For variable length decoding, a minimum and maximum length may be set. Fixed Length, For fixed length decoding, two different lengths may be set.
ENTER/EXIT PROGRAMMING MODE
DEFAULT Codablock F Length Control = Variable Length
Codablock F = Fixed Length
320
QuickScan® QD2100