Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 39 of 48

QuickScan QD2100 General Purpose Corded Handheld Linear Imager Bar Code Reader Product Reference Guide: Symbologies, pages 321 to 330

Pages 321 to 330 of 388, from QuickScan QD2100 General Purpose Corded Handheld Linear Imager Bar Code Reader Product Reference Guide

The original document is the PDF (11 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic QD2110 and Datalogic QD2130

Page 321

Code 93

Code 93, cont. Code 93 Set Length 2 This feature specifies one of the barcode lengths for Code 93 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Follow these instructions to set this feature: 1. Determine the desired character length (from 1 to 50, or 0 to ignore this length). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 3. Scan the barcode: SELECT CODE 93 LENGTH 2 SETTING. 4. Scan the appropriate two digits from the keypad in the Keypad Appendix that represent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake, before the last character scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE

5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.

This completes the procedure. See the table below for some examples of how to set this feature. Table 42. CODE 93 Length 2 Setting Examples STEP

ACTION

EXAMPLES 00 (Ignore This Length)

1

Desired Setting

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT CODE 93 LENGTH 2 SETTING

4

Scan Two Characters From the Keypad Appendix

5

Scan ENTER/EXIT PROGRAMMING MODE

Product Reference Guide

‘0’ and ‘0’

07 Characters

15 Characters

50 Characters

‘0’ and ‘7’

‘1’ and ‘5’

‘5’ AND ‘0’

311

Page 322

Symbologies

Code 93, cont. Code 93 Set Length 2, cont.

ENTER/EXIT PROGRAMMING MODE

Select Code 93 Length 2 Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

312

50 = Length 2 is 50 Characters

QuickScan® QD2100

Page 323

Code 93

Code 93, cont. Code 93 Minimum Reads This feature specifies the minimum number of consecutive times a Code 93 label must be decoded before it is accepted as good read.

ENTER/EXIT PROGRAMMING MODE

DEFAULT Code 93 Minimum Reads = 1

Code 93 Minimum Reads = 2

Code 93 Minimum Reads = 3

Code 93 Minimum Reads = 4

Product Reference Guide

313

Page 324

Symbologies

Code 93, cont. Code 93 Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. •

Choosing Level 1 results in a very conservative decoder at the expense of not being able to read poorly printed or damaged labels.

•

Choosing Level 5 results in a very aggressive decoder. This aggressive behavior allows decoding of poorly printed and damaged labels at the expense of increasing the likelihood of decoding errors.

•

Choosing Level 3, which is the default setting, allows the majority of product labels to be decoded.

There are many factors that determine when to change the decoding level for a particular symbology. These factors include spots, voids, non-uniform bar/space widths, damaged labels, etc. that may be experienced in some barcode labels. If there are many hard to read or damaged labels that cannot be decoded using a conservative setting, increase the decoding level to be more aggressive. If the majority of labels are very good quality labels, or there is a need to decrease the possibility of a decoder error, lower the decoding level to a more conservative level.

ENTER/EXIT PROGRAMMING MODE

Code 93 Decoding Level = Disable

Code 93 Decoding Level = 1

Code 93 Decoding Level = 2

314

QuickScan® QD2100

Page 325

Code 93

Code 93, cont. Code 93 Decoding Level, cont.

DEFAULT Code 93 Decoding Level = 3

Code 93 Decoding Level = 4

Code 93 Decoding Level = 5

Product Reference Guide

315

Page 326

Symbologies

Code 93, cont. Code 93 Quiet Zones Enables/disables fixed length stitching for Code 93.

ENTER/EXIT PROGRAMMING MODE

Code 93 Quiet Zones = No Quiet Zones

Code 93 Quiet Zones = Quiet Zone on one side

Code 93 Quiet Zones = Quiet Zones on two sides

DEFAULT Code 93 Quiet Zones = Auto

Code 93 Quiet Zones = Virtual Quiet Zones on two sides

316

QuickScan® QD2100

Page 327

Code 93

Code 93, cont. Code 93 Stitching Disable/enable fixed or variable length stitching for Code 93.

ENTER/EXIT PROGRAMMING MODE

Code 93 Stitching = Disable

DEFAULT Code 93 Stitching = Enable

Code 93 Character Correlation Enables/disables Character Correlation for Code 93.

ENTER/EXIT PROGRAMMING MODE

Code 93 Character Correlation = Disable

DEFAULT Code 93 Character Correlation = Enable

Product Reference Guide

317

Page 328

Symbologies

Codablock F The following options apply to the Codablock F symbology.

Codablock F Enable/Disable Enables/Disables the ability of the imager to decode Codablock F labels.

ENTER/EXIT PROGRAMMING MODE

DEFAULT Codablock F = Disable

Codablock F = Enable

318

QuickScan® QD2100

Page 329

Codablock F

Codablock F, cont. Codablock F EAN Enable/Disable Enables/Disables the Codablock F EAN subtype (code with FNC1 in the first position).

ENTER/EXIT PROGRAMMING MODE

DEFAULT Codablock F EAN = Disable

Codablock F EAN = Enable

Codablock F AIM Check Specifies if Check Digit calculation algorithm is AIM compliant or not.

ENTER/EXIT PROGRAMMING MODE

Codablock F AIM Check = Disable

DEFAULT Codablock F AIM Check = Enable Check C

Product Reference Guide

319

Page 330

Symbologies

Codablock F, cont. Codablock F Length Control This feature specifies either variable length decoding or fixed length decoding for the Codablock F symbology. Variable Length, For variable length decoding, a minimum and maximum length may be set. Fixed Length, For fixed length decoding, two different lengths may be set.

ENTER/EXIT PROGRAMMING MODE

DEFAULT Codablock F Length Control = Variable Length

Codablock F = Fixed Length

320

QuickScan® QD2100