Page 241
Codabar
Codabar, cont. Codabar Quiet Zones This feature specifies the number of quiet zones for Codabar labels. Quiet zones are blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label.
ENTER/EXIT PROGRAMMING MODE
Codabar Quiet Zones = Quiet Zone on one side
Codabar Quiet Zones = Quiet Zones on two sides
DEFAULT Codabar Quiet Zones = Auto
Codabar Quiet Zones = Virtual Quiet Zones on two sides
Codabar Quiet Zones = Small Quiet Zones on two sides
Product Reference Guide
231
Page 242
Symbologies
Codabar, cont. Codabar Minimum Reads This feature specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as good read..
ENTER/EXIT PROGRAMMING MODE
Codabar Minimum Reads = 1
DEFAULT Codabar Minimum Reads = 2
Codabar Minimum Reads = 3
Codabar Minimum Reads = 4
232
QuickScan® QD2100
Page 243
Codabar
Codabar, cont. Codabar Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. •
Choosing Level 1 results in a very conservative decoder at the expense of not being able to read poorly printed or damaged labels.
•
Choosing Level 5 results in a very aggressive decoder. This aggressive behavior allows decoding of poorly printed and damaged labels at the expense of increasing the likelihood of decoding errors.
•
Choosing Level 3, which is the default setting, allows the majority of product labels to be decoded.
There are many factors that determine when to change the decoding level for a particular symbology. These factors include spots, voids, non-uniform bar/space widths, damaged labels, etc. that may be experienced in some barcode labels. If there are many hard to read or damaged labels that cannot be decoded using a conservative setting, increase the decoding level to be more aggressive. If the majority of labels are very good quality labels, or there is a need to decrease the possibility of a decoder error, lower the decoding level to a more conservative level.
Product Reference Guide
233
Page 244
Symbologies
Codabar, cont. Codabar Decoding Level, cont.
ENTER/EXIT PROGRAMMING MODE
Codabar Decoding Level = 1
Codabar Decoding Level = 2
DEFAULT Codabar Decoding Level = 3
Codabar Decoding Level = 4
Codabar Decoding Level = 5
234
QuickScan® QD2100
Page 245
Codabar
Codabar, cont. Codabar Length Control This feature specifies either variable length decoding or fixed length decoding for the Codabar symbology. Variable Length, For variable length decoding, a minimum and maximum length may be set. Fixed Length, For fixed length decoding, two different lengths may be set.
ENTER/EXIT PROGRAMMING MODE
DEFAULT Codabar Length Control = Variable Length
Codabar Length Control = Fixed Length
Product Reference Guide
235
Page 246
Symbologies
Codabar, cont. Codabar Set Length 1 This feature specifies one of the barcode lengths for Codabar Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s start, stop, check and data characters. The length must include at least one data character. The length can be set from 3 to 50 characters. Follow these instructions to set this feature: 1. Determine the desired character length (from 3 to 50). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 3. Scan the barcode: SELECT CODABAR LENGTH 1 SETTING. 4. Scan the appropriate two digits from the keypad in Appendix E, Keypad, that represent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 29 for some examples of how to set this feature. Table 29. Codabar Length 1 Setting Examples STEP
EXAMPLES
1
Desired Setting (and pad with leading zeroes)
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODABAR LENGTH 1 SETTING
4 5
236
ACTION
Scan Two Characters From
Appendix E, Keypad
03 Characters
‘0’ and ‘3’
09 Characters
15 Characters
50 Characters
‘0’ and ‘9’
‘1’ and ‘5’
‘5’ AND ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
QuickScan® QD2100
Page 247
Codabar
Codabar, cont. Codabar Set Length 1, cont.
ENTER/EXIT PROGRAMMING MODE
Select Codabar Length 1 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
Product Reference Guide
03 = Length 1 is 3 Characters
237
Page 248
Symbologies
Codabar, cont. Codabar Set Length 2 This feature specifies one of the barcode lengths for Codabar Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. The length includes the barcode’s start, stop, check and data characters. The length must include at least one data character. The length can be set from 3 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Follow these instructions to set this feature: 1. Determine the desired character length (from 3 to 50, or 0 to ignore this length). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 3. Scan the barcode: SELECT CODABAR LENGTH 2 SETTING. 4. Scan the appropriate two digits from the keypad in Appendix E, Keypad, that represent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE
5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 30 for some examples of how to set this feature. Table 30. Codabar Length 2 Setting Examples STEP
EXAMPLES
1
Desired Setting (and pad with leading zeroes)
2
Scan ENTER/EXIT PROGRAMMING MODE
3
Scan SELECT CODE 39 LENGTH 2 SETTING
4 5
238
ACTION
Scan Two Characters From
Appendix E, Keypad
00 Ignore This Length
‘0’ and ‘0’
07 Characters
15 Characters
50 Characters
‘0’ and ‘7’
‘1’ and ‘5’
‘5’ AND ‘0’
Scan ENTER/EXIT PROGRAMMING MODE
QuickScan® QD2100
Page 249
Codabar
Codabar, cont. Codabar Set Length 2, cont.
ENTER/EXIT PROGRAMMING MODE
Select CodabarLength 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
Product Reference Guide
50 = Length 2 is 50 Characters
239
Page 250
Symbologies
Codabar, cont. Codabar Interdigit Ratio This feature specifies the ratio between an intercharacter space and module for Codabar labels.
ENTER/EXIT PROGRAMMING MODE
Codabar Interdigit Ratio = Disable
Codabar Interdigit Ratio = 1
Codabar Interdigit Ratio = 2
Codabar Interdigit Ratio = 3
DEFAULT Codabar Interdigit Ratio = 4
Codabar Interdigit Ratio = 5
240