Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 31 of 48

QuickScan QD2100 General Purpose Corded Handheld Linear Imager Bar Code Reader Product Reference Guide: Symbologies, pages 241 to 250

Pages 241 to 250 of 388, from QuickScan QD2100 General Purpose Corded Handheld Linear Imager Bar Code Reader Product Reference Guide

The original document is the PDF (11 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic QD2110 and Datalogic QD2130

Page 241

Codabar

Codabar, cont. Codabar Quiet Zones This feature specifies the number of quiet zones for Codabar labels. Quiet zones are blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label.

ENTER/EXIT PROGRAMMING MODE

Codabar Quiet Zones = Quiet Zone on one side

Codabar Quiet Zones = Quiet Zones on two sides

DEFAULT Codabar Quiet Zones = Auto

Codabar Quiet Zones = Virtual Quiet Zones on two sides

Codabar Quiet Zones = Small Quiet Zones on two sides

Product Reference Guide

231

Page 242

Symbologies

Codabar, cont. Codabar Minimum Reads This feature specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as good read..

ENTER/EXIT PROGRAMMING MODE

Codabar Minimum Reads = 1

DEFAULT Codabar Minimum Reads = 2

Codabar Minimum Reads = 3

Codabar Minimum Reads = 4

232

QuickScan® QD2100

Page 243

Codabar

Codabar, cont. Codabar Decoding Level Decoding Levels are used to configure a barcode symbology decoder to be very aggressive to very conservative depending on a particular customer’s needs. •

Choosing Level 1 results in a very conservative decoder at the expense of not being able to read poorly printed or damaged labels.

•

Choosing Level 5 results in a very aggressive decoder. This aggressive behavior allows decoding of poorly printed and damaged labels at the expense of increasing the likelihood of decoding errors.

•

Choosing Level 3, which is the default setting, allows the majority of product labels to be decoded.

There are many factors that determine when to change the decoding level for a particular symbology. These factors include spots, voids, non-uniform bar/space widths, damaged labels, etc. that may be experienced in some barcode labels. If there are many hard to read or damaged labels that cannot be decoded using a conservative setting, increase the decoding level to be more aggressive. If the majority of labels are very good quality labels, or there is a need to decrease the possibility of a decoder error, lower the decoding level to a more conservative level.

Product Reference Guide

233

Page 244

Symbologies

Codabar, cont. Codabar Decoding Level, cont.

ENTER/EXIT PROGRAMMING MODE

Codabar Decoding Level = 1

Codabar Decoding Level = 2

DEFAULT Codabar Decoding Level = 3

Codabar Decoding Level = 4

Codabar Decoding Level = 5

234

QuickScan® QD2100

Page 245

Codabar

Codabar, cont. Codabar Length Control This feature specifies either variable length decoding or fixed length decoding for the Codabar symbology. Variable Length, For variable length decoding, a minimum and maximum length may be set. Fixed Length, For fixed length decoding, two different lengths may be set.

ENTER/EXIT PROGRAMMING MODE

DEFAULT Codabar Length Control = Variable Length

Codabar Length Control = Fixed Length

Product Reference Guide

235

Page 246

Symbologies

Codabar, cont. Codabar Set Length 1 This feature specifies one of the barcode lengths for Codabar Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s start, stop, check and data characters. The length must include at least one data character. The length can be set from 3 to 50 characters. Follow these instructions to set this feature: 1. Determine the desired character length (from 3 to 50). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 3. Scan the barcode: SELECT CODABAR LENGTH 1 SETTING. 4. Scan the appropriate two digits from the keypad in Appendix E, Keypad, that represent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE

5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 29 for some examples of how to set this feature. Table 29. Codabar Length 1 Setting Examples STEP

EXAMPLES

1

Desired Setting (and pad with leading zeroes)

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT CODABAR LENGTH 1 SETTING

4 5

236

ACTION

Scan Two Characters From

Appendix E, Keypad

03 Characters

‘0’ and ‘3’

09 Characters

15 Characters

50 Characters

‘0’ and ‘9’

‘1’ and ‘5’

‘5’ AND ‘0’

Scan ENTER/EXIT PROGRAMMING MODE

QuickScan® QD2100

Page 247

Codabar

Codabar, cont. Codabar Set Length 1, cont.

ENTER/EXIT PROGRAMMING MODE

Select Codabar Length 1 Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

Product Reference Guide

03 = Length 1 is 3 Characters

237

Page 248

Symbologies

Codabar, cont. Codabar Set Length 2 This feature specifies one of the barcode lengths for Codabar Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. The length includes the barcode’s start, stop, check and data characters. The length must include at least one data character. The length can be set from 3 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Follow these instructions to set this feature: 1. Determine the desired character length (from 3 to 50, or 0 to ignore this length). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 3. Scan the barcode: SELECT CODABAR LENGTH 2 SETTING. 4. Scan the appropriate two digits from the keypad in Appendix E, Keypad, that represent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE

5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 30 for some examples of how to set this feature. Table 30. Codabar Length 2 Setting Examples STEP

EXAMPLES

1

Desired Setting (and pad with leading zeroes)

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT CODE 39 LENGTH 2 SETTING

4 5

238

ACTION

Scan Two Characters From

Appendix E, Keypad

00 Ignore This Length

‘0’ and ‘0’

07 Characters

15 Characters

50 Characters

‘0’ and ‘7’

‘1’ and ‘5’

‘5’ AND ‘0’

Scan ENTER/EXIT PROGRAMMING MODE

QuickScan® QD2100

Page 249

Codabar

Codabar, cont. Codabar Set Length 2, cont.

ENTER/EXIT PROGRAMMING MODE

Select CodabarLength 2 Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

Product Reference Guide

50 = Length 2 is 50 Characters

239

Page 250

Symbologies

Codabar, cont. Codabar Interdigit Ratio This feature specifies the ratio between an intercharacter space and module for Codabar labels.

ENTER/EXIT PROGRAMMING MODE

Codabar Interdigit Ratio = Disable

Codabar Interdigit Ratio = 1

Codabar Interdigit Ratio = 2

Codabar Interdigit Ratio = 3

DEFAULT Codabar Interdigit Ratio = 4

Codabar Interdigit Ratio = 5

240

QuickScan® QD2100