The text of a manual · part 30 of 48
QuickScan QD2100 General Purpose Corded Handheld Linear Imager Bar Code Reader Product Reference Guide: Symbologies, pages 231 to 240
Pages 231 to 240 of 388, from QuickScan QD2100 General Purpose Corded Handheld Linear Imager Bar Code Reader Product Reference Guide
The original document is the PDF (11 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic QD2110 and Datalogic QD2130
Page 231
Datalogic 2 of 5
Datalogic 2 of 5, cont. Datalogic 2 of 5 Set Length 2, cont.
ENTER/EXIT PROGRAMMING MODE
Select Datalogic 2 of 5 Length 2 Setting
Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL
DEFAULT
Product Reference Guide
50 = Length 2 is 50 Characters
221
Page 232
Symbologies
Datalogic 2 of 5 Interdigit Maximum Ratio This feature specifies the maximum ratio between intercharacter space and module for Datalogic 2 of 5.
ENTER/EXIT PROGRAMMING MODE
Datalogic 2 of 5 Interdigit Maximum Ratio = Disable
Datalogic 2 of 5 Interdigit Maximum Ratio = 1
Datalogic 2 of 5 Interdigit Maximum Ratio = 2
Datalogic 2 of 5 Interdigit Maximum Ratio = 3
DEFAULT Datalogic 2 of 5 Interdigit Maximum Ratio = 4
Datalogic 2 of 5 Interdigit Maximum Ratio = 5
222
QuickScan® QD2100
Page 233
Datalogic 2 of 5
Datalogic 2 of 5 Interdigit Maximum Ratio, cont.
Datalogic 2 of 5 Interdigit Maximum Ratio = 6
Datalogic 2 of 5 Interdigit Maximum Ratio = 7
Datalogic 2 of 5 Interdigit Maximum Ratio = 8
Datalogic 2 of 5 Interdigit Maximum Ratio = 9
Datalogic 2 of 5 Interdigit Maximum Ratio = 10
Product Reference Guide
223
Page 234
Symbologies
Datalogic 2 of 5, cont. Datalogic 2 of 5 Character Correlation When correlation is enabled, the barcode reader will combine label data from multiple scans when decoding. Enabling correlation will help the scanner read labels that have some spots and/or voids. It may also help read labels that have damaged areas. Enabling correlation will also increase the chances that a label will be read incorrectly.
ENTER/EXIT PROGRAMMING MODE
DEFAULT I 2 of 5 Character Correlation = Disable
I 2 of 5 Character Correlation = Enable
224
QuickScan® QD2100
Page 235
Datalogic 2 of 5
Datalogic 2 of 5, cont. Datalogic 2 of 5 Stitching This option enables/disables stitching for Datalogic 2 of 5 labels. When parts of a Datalogic 2 of 5 barcode are presented to the reader with this feature enabled, the barcode parts will be assembled by the reader’s software, and the data will be decoded if all barcode proofing requirements are met.
ENTER/EXIT PROGRAMMING MODE
DEFAULT Datalogic 2 of 5 Stitching = Disable
Datalogic 2 of 5 Stitching = Enable
Product Reference Guide
225
Page 236
Symbologies
Codabar The following options apply to the Codabar symbology.
Codabar Enable/Disable When disabled, the reader will not read Codabar barcodes.
ENTER/EXIT PROGRAMMING MODE
DEFAULT Codabar = Disable
Codabar = Enable
226
QuickScan® QD2100
Page 237
Codabar
Codabar, cont. Codabar Check Character Calculation Enable this option to enables/disables calculation and verification of an optional Codabar check character. When disabled, any check characters in the label are treated as data characters.
ENTER/EXIT PROGRAMMING MODE
DEFAULT Codabar Check Character Calculation = Don’t Calculate
Codabar Check Character Calculation = Enable AIM standard check char.
Codabar Check Character Calculation = Enable Modulo 10 check char.
Product Reference Guide
227
Page 238
Symbologies
Codabar, cont. Codabar Check Character Transmission Enable this option to transmit the check character along with Codabar barcode data.
ENTER/EXIT PROGRAMMING MODE
Codabar Check Character Transmission = Don’t Send
DEFAULT Codabar Check Character Transmission = Send
Codabar Start/Stop Character Transmission Enable this option to enable/disable transmission of Codabar start and stop characters.
ENTER/EXIT PROGRAMMING MODE
Codabar Start/Stop Character Transmission = Don’t Transmit
DEFAULT Codabar Start/Stop Character Transmission = Transmit
228
QuickScan® QD2100
Page 239
Codabar
Codabar, cont. Codabar Start/Stop Character Set This option specifies the format of transmitted Codabar start/stop characters.
ENTER/EXIT PROGRAMMING MODE
Codabar Check Character Set = ABCD/TN*E
Codabar Check Character Set = ABCD/ABCD
Codabar Check Character Set = abcd/tn*e
DEFAULT Codabar Check Character Set = abcd/abcd
Product Reference Guide
229
Page 240
Symbologies
Codabar, cont. Codabar Start/Stop Character Match When enabled, this option requires that start and stop characters match.
ENTER/EXIT PROGRAMMING MODE
DEFAULT Codabar Start/Stop Character Match = Don’t Require Match
Codabar Start/Stop Character Match = Require Match
230
QuickScan® QD2100