Page 171

GS1 DataBar

GS1 DataBar

TM

TM

Expanded

Expanded, cont.

GS1 DataBar Expanded Set Length 1, cont.

ENTER/EXIT PROGRAMMING MODE

Select GS1 DataBar Expanded Set Length 1 Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

Product Reference Guide

01 = Length 1 is 1 Character

161

Page 172

Symbologies

GS1 DataBar

TM

Expanded, cont.

GS1 DataBar Expanded Set Length 2 This feature specifies one of the barcode lengths for GS1 DataBar Expanded Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 1 to 74 characters. A setting of 0 specifies to ignore this length (only one fixed length). Follow these instructions to set this feature: 1. Determine the desired character length (from 1 to 74). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 3. Scan the barcode: SELECT GS1 DataBar EXPANDED LENGTH 2 SETTING. 4. Scan the appropriate two digits from the keypad in Appendix E, Keypad, that represent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE

5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 20 for some examples of how to set this feature. Table 20. GS1 DataBar Expanded Length 2 Setting Examples STEP

EXAMPLES 00 (ignore second length)

1

Desired Setting

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT GS1 DataBar EXPANDED LENGTH 2 SETTING

4 5

162

ACTION

Scan Two Characters From

Appendix E, Keypad

‘0’ and ‘0’

07 Characters

‘0’ and ‘7’

52 Characters

74 Characters

‘5’ and ‘2’

‘7’ and ‘4’

Scan ENTER/EXIT PROGRAMMING MODE

QuickScan® QD2100

Page 173

GS1 DataBar

GS1 DataBar

TM

TM

Expanded

Expanded, cont.

GS1 DataBar Expanded Set Length 2, cont.

ENTER/EXIT PROGRAMMING MODE

Select GS1 DataBar Expanded Set Length 2 Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

Product Reference Guide

74 = Length 2 is 74 Characters

163

Page 174

Symbologies

GS1 DataBar Limited TM

The following options apply to the GS1 DataBar Limited (formerly RSS Limited) symbology.

GS1 DataBar Limited Enable/Disable When disabled, the reader will not read GS1 DataBar Limited barcodes.

ENTER/EXIT PROGRAMMING MODE

DEFAULT GS1 DataBar Limited = Disable

GS1 DataBar Limited = Enable

GS1 DataBar Limited GS1-128 Emulation When enabled, GS1 DataBar Limited barcodes will be translated to the GS1-128 label data format.

ENTER/EXIT PROGRAMMING MODE

DEFAULT GS1 DataBar Limited GS1-128 Emulation = Disable

GS1 DataBar Limited GS1-128 Emulation = Enable

164

QuickScan® QD2100

Page 175

GS1 DataBar

GS1 DataBar

TM

TM

Limited

Limited, cont.

GS1 DataBar Limited Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar Limited label must be decoded before it is accepted as good read.

ENTER/EXIT PROGRAMMING MODE

DEFAULT GS1 DataBar Limited Minimum Reads = 1

GS1 DataBar Limited Minimum Reads = 2

GS1 DataBar Limited Minimum Reads = 3

GS1 DataBar Limited Minimum Reads = 4

Product Reference Guide

165

Page 176

Symbologies

Code 39 The following options apply to the Code 39 symbology.

Code 39 Enable/Disable When disabled, the reader will not read Code 39 barcodes.

ENTER/EXIT PROGRAMMING MODE

Code 39 = Disable

DEFAULT Code 39 = Enable

166

QuickScan® QD2100

Page 177

Code 39

Code 39, cont. Code 39 Check Character Calculation Enable this option to enables/disables calculation and verification of an optional Code 39 check character. When disabled, any check character in the label is treated as a data character.

ENTER/EXIT PROGRAMMING MODE

Code 39 Check Character Calculation = Don’t Calculate

DEFAULT Code 39 Check Character Calculation = Calculate Std Check

Code 39 Check Character Calculation = Calculate Mod 7 Check

Code 39 Check Character Calculation = Enable Italian Post Check

Code 39 Check Character Calculation = Enable Daimler Chrysler Check

Product Reference Guide

167

Page 178

Symbologies

Code 39, cont. Code 39 Check Character Transmission Enable this option to transmit the check character along with Code 39 barcode data.

ENTER/EXIT PROGRAMMING MODE

Code 39 Check Character Transmission = Don’t Send

DEFAULT Code 39 Check Character Transmission = Send

Code 39 Start/Stop Character Transmission Enable this option to enable/disable transmission of Code 39 start and stop characters.

ENTER/EXIT PROGRAMMING MODE

DEFAULT Code 39 Start/Stop Character Transmission = Don’t Transmit

Code 39 Start/Stop Character Transmission = Transmit

168

QuickScan® QD2100

Page 179

Code 39

Code 39, cont. Code 39 Full ASCII In Code 39 decoding, this enables/disables the translation of Code 39 characters to Code 39 full-ASCII characters.

ENTER/EXIT PROGRAMMING MODE

DEFAULT Code 39 Full ASCII = Disable

Code 39 Full ASCII = Enable

Product Reference Guide

169

Page 180

Symbologies

Code 39, cont. Code 39 Quiet Zones This feature specifies the number of quiet zones for Code 39 labels. Quiet zones are blank areas at the ends of a barcode and are typically 10 times the width of the narrowest bar or space in the label.

ENTER/EXIT PROGRAMMING MODE

Code 39 Quiet Zones = Quiet Zone on one side

Code 39 Quiet Zones = Quiet Zones on two sides

DEFAULT Code 39 Quiet Zones = Auto

Code 39 Quiet Zones = Virtual Quiet Zones on two sides

Code 39 Quiet Zones = Small Quiet Zones on two sides

170