Page 161

Add-Ons

Add-Ons, cont. Optional GS1-128 Add-On Timer, cont.

ENTER/EXIT PROGRAMMING MODE

Optional GS1-128 Add-On Timer = 180ms

Optional GS1-128 Add-On Timer = 200ms

Optional GS1-128 Add-On Timer = 220ms

Optional GS1-128 Add-On Timer = 240ms

Optional GS1-128 Add-On Timer = 260ms

Optional GS1-128 Add-On Timer = 280ms

Optional GS1-128 Add-On Timer = 300ms

Product Reference Guide

151

Page 162

Symbologies

Add-Ons, cont. P2 Add-Ons Minimum Reads This feature specifies the minimum number of times a P2 add-on must be read before it is marked as valid and then combined with a base label.

ENTER/EXIT PROGRAMMING MODE

P2 Add-Ons Minimum Reads = 1

DEFAULT P2 Add-Ons Minimum Reads = 2

P2 Add-Ons Minimum Reads = 3

P2 Add-Ons Minimum Reads = 4

152

QuickScan® QD2100

Page 163

Add-Ons

Add-Ons, cont. P5 Add-Ons Minimum Reads This feature specifies the minimum number of times a P5 add-on must be read before it is marked as valid and then combined with a base label.

ENTER/EXIT PROGRAMMING MODE

DEFAULT P5 Add-Ons Minimum Reads = 1

P5 Add-Ons Minimum Reads = 2

P5 Add-Ons Minimum Reads = 3

P5 Add-Ons Minimum Reads = 4

Product Reference Guide

153

Page 164

Symbologies

Add-Ons, cont. GS1-128 Add-Ons Minimum Reads This feature specifies the minimum number of times an GS1-128 add-on must be read before it is marked as valid and then combined with a base label.

ENTER/EXIT PROGRAMMING MODE

DEFAULT GS1-128 Add-Ons Minimum Reads = 1

GS1-128 Add-Ons Minimum Reads = 2

GS1-128 Add-Ons Minimum Reads = 3

GS1-128 Add-Ons Minimum Reads = 4

154

QuickScan® QD2100

Page 165

GS1 DataBar

TM

Omnidirectional

GS1 DataBar Omnidirectional TM

The following options apply to the GS1 DataBar Omnidirectional (formerly RSS-14) symbology.

GS1 DataBar Omnidirectional Enable/Disable When disabled, the reader will not read GS1 DataBar Omnidirectional barcodes.

ENTER/EXIT PROGRAMMING MODE

DEFAULT GS1 DataBar Omnidirectional = Disable

GS1 DataBar Omnidirectional = Enable

GS1 DataBar Omnidirectional GS1-128 Emulation When enabled, GS1 DataBar Omnidirectional barcodes will be translated to the GS1128 label data format.

ENTER/EXIT PROGRAMMING MODE

DEFAULT GS1 DataBar Omnidirectional GS1-128 Emulation = Disable

GS1 DataBar Omnidirectional GS1-128 Emulation = Enable

Product Reference Guide

155

Page 166

Symbologies

GS1 DataBar

TM

Omnidirectional, cont.

GS1 DataBar Omnidirectional Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar Omnidirectional label must be decoded before it is accepted as good read.

ENTER/EXIT PROGRAMMING MODE

DEFAULT GS1 DataBar Omnidirectional Minimum Reads = 1

GS1 DataBar Omnidirectional Minimum Reads = 2

GS1 DataBar Omnidirectional Minimum Reads = 3

GS1 DataBar Omnidirectional Minimum Reads = 4

156

QuickScan® QD2100

Page 167

GS1 DataBar

TM

Expanded

GS1 DataBar Expanded TM

The following options apply to the GS1 DataBar Expanded (formerly RSS Expanded) symbology.

GS1 DataBar Expanded Enable/Disable When disabled, the reader will not read GS1 DataBar Expanded barcodes.

ENTER/EXIT PROGRAMMING MODE

DEFAULT GS1 DataBar Expanded = Disable

GS1 DataBar Expanded = Enable

GS1 DataBar Expanded GS1-128 Emulation When enabled, GS1 DataBar Expanded barcodes will be translated to the GS1-128 label data format.

ENTER/EXIT PROGRAMMING MODE

DEFAULT GS1 DataBar Expanded GS1-128 Emulation = Disable

GS1 DataBar Expanded GS1-128 Emulation = Enable

Product Reference Guide

157

Page 168

Symbologies

GS1 DataBar

TM

Expanded, cont.

GS1 DataBar Expanded Minimum Reads This feature specifies the minimum number of consecutive times a GS1 DataBar Expanded label must be decoded before it is accepted as good read.

ENTER/EXIT PROGRAMMING MODE

DEFAULT GS1 DataBar Expanded Minimum Reads = 1

GS1 DataBar Expanded Minimum Reads = 2

GS1 DataBar Expanded Minimum Reads = 3

GS1 DataBar Expanded Minimum Reads = 4

158

QuickScan® QD2100

Page 169

GS1 DataBar

GS1 DataBar

TM

TM

Expanded

Expanded, cont.

GS1 DataBar Expanded Length Control This feature specifies either variable length decoding or fixed length decoding for the GS1 DataBar Expanded symbology. Variable Length, For variable-length decoding, a minimum length may be set. Fixed Length, For fixed-length decoding, two different lengths may be set.

ENTER/EXIT PROGRAMMING MODE

DEFAULT GS1 DataBar Expanded Length Control = Variable Length

GS1 DataBar Expanded Length Control = Fixed Length

Product Reference Guide

159

Page 170

Symbologies

GS1 DataBar

TM

Expanded, cont.

GS1 DataBar Expanded Set Length 1 This feature specifies one of the barcode lengths for GS1 DataBar Expanded Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the barcode’s data characters only. The length can be set from 1 to 74 characters. Follow these instructions to set this feature: 1. Determine the desired character length (from 1 to 74). Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 2. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 3. Scan the barcode: SELECT GS1 DataBar EXPANDED LENGTH 1 SETTING. 4. Scan the appropriate two digits from the keypad in Appendix E, Keypad, that represent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE

5. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 19 for some examples of how to set this feature. Table 19. GS1 DataBar Expanded Length 1 Setting Examples STEP

EXAMPLES

1

Desired Setting

2

Scan ENTER/EXIT PROGRAMMING MODE

3

Scan SELECT GS1 DataBar EXPANDED LENGTH 1SETTING

4 5

160

ACTION

Scan Two Characters From

Appendix E, Keypad

01 Character

‘0’ and ‘1’

07 Characters

‘0’ and ‘7’

52 Characters

74 Characters

‘5’ and ‘2’

‘7’ AND ‘4’

Scan ENTER/EXIT PROGRAMMING MODE

QuickScan® QD2100