Page 77

Chapter 7 Keyboard Interface Introduction Use the programming barcodes in this chapter to select options for USB Keyboard and Wedge Interfaces.

Standard Factory Settings Reference Appendix B, Standard Defaults for a listing of standard factory settings.

Scancode Tables Information about control character emulation which applies to keyboard interfaces is listed in Appendix F, Scancode Tables.

Product Reference Guide

67

Page 78

Keyboard Interface

Country Mode This feature specifies the country/language supported by the keyboard. Only the following interfaces support ALL Country Modes. •

USB Keyboard (without alternate key encoding)

•

AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Std Key Encoding

•

Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard

•

AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 without Alternate Key

•

Keyboard Wedge for IBM AT PS2 without alternate key encoding but without external keyboard

All other interfaces support ONLY the following Country Modes: U.S., Belgium, Britain, France, Germany, Italy, Spain, Sweden.

ENTER/EXIT PROGRAMMING MODE

DEFAULT Country Mode = U.S.

Country Mode = Belgium

Country Mode = Britain

Supports only the interfaces listed in theCountry Mode feature description. Country Mode = Croatia

Supports only the interfaces listed in theCountry Mode feature description. Country Mode = Czechoslovakia

68

QuickScan® QD2100

Page 79

Country Mode

Country Mode, continued

ENTER/EXIT PROGRAMMING MODE

Supports only the interfaces listed in theCountry Mode feature description. Country Mode = Denmark

Country Mode = France

Country Mode = Germany

Supports only the interfaces listed in theCountry Mode feature description. Country Mode = Hungary

Country Mode = Italy

Supports only the interfaces listed in theCountry Mode feature description. Country Mode = Japanese 106-key

Supports only the interfaces listed in theCountry Mode feature description. Country Mode = Norway

Product Reference Guide

69

Page 80

Keyboard Interface

Country Mode, continued

ENTER/EXIT PROGRAMMING MODE

Supports only the interfaces listed in theCountry Mode feature description. Country Mode = Poland

Supports only the interfaces listed in theCountry Mode feature description. Country Mode = Portugal

Supports only the interfaces listed in theCountry Mode feature description. Country Mode = Romania

Supports only the interfaces listed in theCountry Mode feature description. Country Mode = Slovakia

Country Mode = Spain

Country Mode = Sweden

Supports only the interfaces listed in theCountry Mode feature description. Country Mode = Switzerland

70

QuickScan® QD2100

Page 81

Caps Lock State

Caps Lock State This option specifies the format in which the reader sends character data. This applies to keyboard wedge interfaces. This does not apply when an alternate key encoding keyboard is selected.

ENTER/EXIT PROGRAMMING MODE

DEFAULT Caps Lock State = Caps Lock OFF

Caps Lock State = Caps Lock ON

Caps Lock State = AUTO Caps Lock Enable

Numlock This option specifies the setting of the Numbers Lock (Numlock) key while in keyboard wedge interface. This only applies to alternate key encoding interfaces. It does not apply to USB keyboard.

ENTER/EXIT PROGRAMMING MODE

DEFAULT Numlock = Numlock key unchanged

Numlock = Numlock key toggled

Product Reference Guide

71

Page 82

Keyboard Interface

Send Control Characters This feature Specifies how the reader transmits ASCII control characters to the host. Reference Appendix F, Scancode Tables for more information about control characters. Options are as follows: Control Character 00, Characters from 00 to 0x1F are sent as control character

Ctrl+Keys, special keys are located from 0x80 to 0xA1. Control Character 01, Characters from 00 to 0x1F are sent as control character

Ctrl+Capital Key, special keys are located from 0x80 to 0xA1. Control Character 02, Special keys are located from 00 to 0x1F and characters from

0x80 to 0xFE are intended as an extended ASCII table (Microsoft Windows Codepage 1252, see Microsoft Windows Codepage 1252 on page 374).

ENTER/EXIT PROGRAMMING MODE

DEFAULT Wedge Send Control Characters = 00

Wedge Send Control Characters = 01

Wedge Send Control Characters = 02

72

QuickScan® QD2100

Page 83

Wedge Quiet Interval

Wedge Quiet Interval This option specifies the amount of time to look for keyboard activity before the reader breaks the keyboard connection in order to transmit data to host. The selectable range for this feature is from 0 to 990ms in 10ms increments.

This feature applies ONLY to the Keyboard Wedge interface. NOTE

Follow these instructions to set this feature: 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT WEDGE QUIET INTERVAL SETTING. 5. Scan the appropriate two digits from the keypad in Appendix E, Keypad, that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE

6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode.

This completes the procedure to set the Wedge Quiet Interval. See Table 14 for some examples of how to set this feature. Table 14. Timeout Setting Examples STEP

ACTION

EXAMPLES

1

Desired Setting

10ms

150ms

600ms

850ms

2

Divide by 10 (and pad with leading zeroes)

01

15

60

85

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT WEDGE QUIET INTERVAL SETTING ‘1’ and ‘5’

‘6’ and ‘0’

‘8’ and ‘5’

5 6

Scan Two Characters From

Appendix E, Keypad

‘0’ and ‘1’

Scan ENTER/EXIT PROGRAMMING MODE

Product Reference Guide

73

Page 84

Keyboard Interface

Wedge Quiet Interval, cont.

ENTER/EXIT PROGRAMMING MODE

Select Wedge Quiet Interval Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

74

10 = Quiet Interval of 100 ms

QuickScan® QD2100

Page 85

Intercharacter Delay

Intercharacter Delay This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay.

This feature applies ONLY to the Keyboard Wedge interface. NOTE

To set the delay: 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT INTERCHARACTER DELAY SETTING. 5. Scan the appropriate two digits from the keypad in Appendix E, Keypad, that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE

6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 14 for some examples of how to set this feature. Table 15. Intercharacter Delay Setting Examples STEP

ACTION

EXAMPLES

1

Desired Setting

50ms

150ms

600ms

850ms

2

Divide by 10 (and pad with leading zeroes to yield two-digits)

05

15

60

85

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT INTERCHARACTER DELAY SETTING ‘1’ and ‘5’

‘6’ and ‘0’

‘8’ and ‘5’

5 6

Scan Two Characters From

Appendix E, Keypad

‘0’ and ‘5’

Scan ENTER/EXIT PROGRAMMING MODE

Product Reference Guide

75

Page 86

Keyboard Interface

Intercharacter Delay, cont.

ENTER/EXIT PROGRAMMING MODE

Intercharacter Delay = No Delay

Select Intercharacter Delay Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

76

00 = No Intercharacter Delay

QuickScan® QD2100

Page 87

Intercode Delay

Intercode Delay Specifies the delay between labels transmitted to the host for this interface. The selectable range for this feature is from 0 to 99 seconds. Follow these instructions to set this feature: 1. Determine the desired setting. 2. Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT INTERCODE DELAY SETTING. 5. Scan the appropriate two digits from the keypad in Appendix E, Keypad, that represent the duration which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE

6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 16 for some examples of how to set this feature. Table 16. Wedge Intercode Delay Examples STEP

ACTION

EXAMPLES

1

Desired Setting

2

Pad with leading zero(es)

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT INTERCODE DELAY SETTING

5 7

Scan Two Characters From

Appendix E, Keypad

No Delay

5 Seconds

60 Seconds

99 Seconds

00

05

60

99

‘0’ and ‘5’

‘6’ and ‘0’

‘9’ AND ‘9’

‘0’ and ‘0’

Scan ENTER/EXIT PROGRAMMING MODE

Product Reference Guide

77

Page 88

Keyboard Interface

Intercode Delay, cont.

ENTER/EXIT PROGRAMMING MODE

Set Intercode Delay

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

78

00 = No Wedge Intercode Delay

QuickScan® QD2100

Page 89

USB Keyboard Speed

USB Keyboard Speed This option specifies the USB poll rate for a USB keyboard.

This feature applies ONLY to the USB Keyboard interface. NOTE

ENTER/EXIT PROGRAMMING MODE

DEFAULT USB Keyboard Speed = 1ms

USB Keyboard Speed = 2ms

USB Keyboard Speed = 3ms

USB Keyboard Speed = 4ms

USB Keyboard Speed = 5ms

Product Reference Guide

79

Page 90

Keyboard Interface

USB Keyboard Speed, continued

ENTER/EXIT PROGRAMMING MODE

USB Keyboard Speed = 6ms

USB Keyboard Speed = 7ms

USB Keyboard Speed = 8ms

USB Keyboard Speed = 9ms

USB Keyboard Speed = 10ms

80