Page 67

ACK NAK Options

ACK NAK Timeout Value, cont.

ENTER/EXIT PROGRAMMING MODE

Select ACK NAK Timeout Value Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

Product Reference Guide

01 ACK NAK Timeout value is 200ms

57

Page 68

RS-232/USB-Com Interfaces

ACK NAK Retry Count This feature specifies the number of times the reader retries a label transmission due to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies unlimited retries. To set this feature: 1. Determine the desired setting. 2. Pad the number with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT ACK NAK RETRY COUNT SETTING. 5. Scan the appropriate three digits from the keypad in Appendix E, Keypad, that represent the number which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake before the last character, scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. NOTE

6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 11 for some examples of how to set this feature. Table 11. ACK NAK Retry Count Setting Examples STEP

EXAMPLES Disable Retry Count

3 Retries

54 Retries

Unlimited Retries

000

003

054

255

‘0’, ‘0’ and ‘3’

‘0’, ‘5’ and ‘4’

‘2’, ‘5’ and ‘5’

1

Desired Setting

2

Pad with leading zero(es)

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT ACK NAK RETRY COUNT SETTING

5 6

58

ACTION

Scan Three Characters From

Appendix E, Keypad

‘0’, ‘0’ and ‘0’

Scan ENTER/EXIT PROGRAMMING MODE

QuickScan® QD2100

Page 69

ACK NAK Options

ACK NAK Retry Count, cont.

ENTER/EXIT PROGRAMMING MODE

Select ACK NAK Retry Count Setting

Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning. CANCEL

DEFAULT

Product Reference Guide

003 = 3 Retries

59

Page 70

RS-232/USB-Com Interfaces

ACK NAK Error Handling This feature specifies the method the reader uses to handle receive errors detected while waiting for an ACK character from the host. Options are: • Ignore errors detected • Process error as valid ACK character • Process error as valid NAK character

ENTER/EXIT PROGRAMMING MODE

DEFAULT ACK NAK Error Handling = Ignore Errors Detected

ACK NAK Error Handling = Process Error as Valid ACK Character

ACK NAK Error Handling = Process Error as Valid NAK Character

60

QuickScan® QD2100

Page 71

Indicate Transmission Failure

Indicate Transmission Failure This option enables/disables the reader’s ability to sound an error beep to indicate a transmission failure while in ACK/NAK mode.

ENTER/EXIT PROGRAMMING MODE

Indicate Transmission Failure = Disable Indication

DEFAULT Indicate Transmission Failure = Enable Indication

Product Reference Guide

61

Page 72

RS-232/USB-Com Interfaces

Disable Character Specifies the value of the RS-232 host command used to disable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected.

NOTE

Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit data is not recognized when the option Data Bits has been set as 7 Data Bits.

To set the value: 1. Determine the desired character or value. A setting of 0xFF indicates the the Disable Character is not used (not available). 2. Use the ASCII Chart on the inside back cover of this manual to find the hex equivalent for the desired character/value. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT DISABLE CHARACTER SETTING. 5. Scan the appropriate two alpha-numeric characters from the keypad in Appendix E, Keypad, that represent the desired character/value in step 1 above. The second character will cause a two-beep indication. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 12 for some examples of how to set this feature. Table 12. Disable Character Setting Examples STEP

EXAMPLES

1

Desired character/value

‘d’

‘}’

‘D’

Disable Command Not Used

2

Hex equivalent

0x64

0x7D

0x44

0xFF

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT DISABLE CHARACTER VALUE SETTING ‘7’ and ‘D’

‘4’ and ‘4’

‘F’ AND ‘F’

5 6

62

ACTION

Scan Two Characters From

Appendix E, Keypad

‘6’ and ‘4’

Scan ENTER/EXIT PROGRAMMING MODE

QuickScan® QD2100

Page 73

Disable Character

Disable Character, cont.

ENTER/EXIT PROGRAMMING MODE

Select Disable Character Setting

DEFAULT

Product Reference Guide

0x44 = Disable Character is ‘D’

63

Page 74

RS-232/USB-Com Interfaces

Enable Character Specifies the value of the RS-232 host command used to enable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected.

NOTE

Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit data is not recognized when the option Data Bits has been set as 7 Data Bits.

To set this feature: Determine the desired character or value. A setting of 0xFF indicates the the Enable Character is not used (not available). 1. Determine the desired character or value. 2. Use the ASCII Chart on the inside back cover of this manual to find the hex equivalent for the desired character/value. 3. Scan the ENTER/EXIT PROGRAMMING MODE barcode to enter Programming Mode. 4. Scan the barcode: SELECT ENABLE CHARACTER SETTING. 5. Scan the appropriate two alpha-numeric characters from the keypad in Appendix E, Keypad, that represent the desired character/value in step 2 above. The second character will cause a two-beep indication. 6. Scan the ENTER/EXIT PROGRAMMING MODE barcode to exit Programming Mode. This completes the procedure. See Table 13 for some examples of how to set this feature. Table 13. Enable Character Setting Examples STEP

EXAMPLES

1

Desired character/value

‘e’

‘}’

‘E’

Enable Command Not Used

2

Hex equivalent

0x65

0x7D

0x45

0xFF

3

Scan ENTER/EXIT PROGRAMMING MODE

4

Scan SELECT DISABLE CHARACTER VALUE SETTING ‘7’ and ‘D’

‘4’ and ‘5’

‘F’ AND ‘F’

5 6

64

ACTION

Scan Two Characters From

Appendix E, Keypad

‘6’ and ‘5’

Scan ENTER/EXIT PROGRAMMING MODE

QuickScan® QD2100

Page 75

Enable Character

Enable Character, cont.

ENTER/EXIT PROGRAMMING MODE

Select Enable Character Setting

DEFAULT

Product Reference Guide

0x45 = Enable Character is ‘E’

65

Page 76

RS-232/USB-Com Interfaces

NOTES

66

QuickScan® QD2100