Page 37

Chapter 6 RS-232 Introduction This chapter describes how to set up the scanner with an RS-232 host. The RS-232 interface is used to connect the scanner to point-of-sale devices, host computers, or other devices with an available RS-232 port (e.g., com port). If the host is not listed in Table 6, refer to the documentation for the host device to set communication parameters to match the host.

The scanner uses TTL RS-232 signal levels, which will interface with most system architectures. NOTE

Throughout the programming bar code menus, default values are indicated with asterisks (*).

* Indicates Default

Product Reference Guide

*Baud Rate 57,600

Feature/Option

31

Page 38

RS-232

Connecting an RS-232 Interface This connection is made directly from the scanner to the host computer. Figure 8. RS-232 Direct Connection

Interface Cable Serial Port Connector to Host

Power Supply Cable

Interface cables vary depending on configuration. The connectors illustrated in Figure 8 are examples only. The connectors may be different than those illustrated, but the steps to connect the scanner remain the same. NOTE

1. Attach the modular connector of the RS-232 interface cable to the cable interface port on the scanner (see Installing the Interface Cable on page 6). 2. Connect the other end of the RS-232 interface cable to the serial port on the host. 3. Connect the power supply1 to the serial connector end of the RS-232 interface cable. Plug the power supply into an appropriate outlet. 4. Select the RS-232 host type by scanning the appropriate bar code from RS-232 Host Types on page 36. 5. To modify any other parameter options, scan the appropriate bar codes in this chapter. Refer to RS-232 Host Commands on page 179 for a listing of host commands the scanner will respond to when in RS-232 interface mode. NOTE

1. Use only aDatalogic power supply approved for this product.

32

QuickScan® L

Page 39

RS-232 Parameter Defaults

RS-232 Parameter Defaults Table 5 lists the defaults for RS-232 host parameters. If any option needs to be changed, scan the appropriate bar code(s) provided in the Parameter Descriptions section beginning on page 33.

See Appendix B, Standard Defaults for all user preferences, hosts, symbologies, and miscellaneous default parameters. NOTE Table 5. RS-232 Defaults Parameter

Default

Page Number

RS-232 Host Parameters RS-232 Host Types

Standard

36

Baud Rate

9600

37

Parity Type

None

38

Stop Bit Select

1 Stop Bit

39

Data Bits (ASCII Format)

8-Bit

39

Check Receive Errors

Enable

40

Hardware Handshaking

None

42

Software Handshaking

None

44

Host Serial Response Time-out

2 Sec

45

RTS Line State

Low RTS

46

Beep on <BEL>

Disable

46

Intercharacter Delay

0 msec

47

Nixdorf Beep/LED Options

Normal Operation

48

Ignore Unknown Characters

Send Bar Code

48

RS-232 Host Parameters Various RS-232 hosts are set up with their own parameter default settings (Table 6). Selecting the ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, Olivetti, Omron, or terminal sets the defaults listed in Table 6. Selecting the ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS terminal enables the transmission of code ID characters listed in Table 7 on page 34. These code ID characters are not programmable and are separate from the Transmit Code ID feature. The Transmit Code ID feature should not be enabled for these terminals. Product Reference Guide

33

Page 40

RS-232

Table 6. Terminal Specific RS-232

Fujitsu

WincorNixdorf Mode A

WincorNixdorf Mode B/ OPOS

Olivetti

Omron

Yes

Yes

Yes

Yes

Yes

Yes

Data as is

Data/Suffix

Data/Suffix

Data/Suffix

Data/Suffix

Prefix/Data/Suffix

Data/Suffix

Suffix

CR/LF (7013)

CR (1013)

CR (1013)

CR (1013)

CR (1013)

ETX (1002)

CR (1013)

Baud Rate

9600

9600

9600

9600

9600

9600

9600

Parity

None

Even

None

Odd

Odd

Even

None

Hardware Handshaking

None

RTS/CTS Option 3

None

RTS/CTS Option 3

RTS/CTS Option 3

None

None

Software Handshaking

None

None

None

None

None

Ack/Nak

None

Serial Response Time-out

2 Sec.

9.9 Sec.

2 Sec.

9.9 Sec.

9.9 Sec.

9.9 Sec.

9.9 Sec.

Stop Bit Select

One

One

One

One

One

One

One

ASCII Format

8-Bit

8-Bit

8-Bit

8-Bit

8-Bit

7-Bit

8-Bit

Beep On <BEL>

Disable

Disable

Disable

Disable

Disable

Disable

Disable

RTS Line State

Low

High

Low

Low

Low = No data to send

Low

High

Prefix

None

None

None

None

None

STX (1003)

None

Standard (Default)

ICL

No

Data Transmission Format

Parameter

Transmit Code ID

*In the Nixdorf Mode B, if CTS is Low, scanning is disabled. When CTS is High, the user can scan bar codes. **If Nixdorf Mode B is scanned without the scanner connected to the proper host, it may appear unable to scan. If this happens, scan a different RS-232 host type within 5 seconds of cycling power to the scanner.

Table 7. Terminal Specific Code ID Characters

34

ICL

Fujitsu

WincorNixdorf Mode A

WincorNixdorf Mode B/OPOS

Olivetti

Omron

UPC-A

A

A

A

A

A

A

UPC-E

E

E

C

C

C

E

EAN-8/JAN-8

FF

FF

B

B

B

FF

QuickScan® L

Page 41

RS-232 Host Parameters

Table 7. Terminal Specific Code ID Characters ICL

Fujitsu

WincorNixdorf Mode A

WincorNixdorf Mode B/OPOS

Olivetti

Omron

EAN-13/JAN-13

F

F

A

A

A

F

Code 39

C <len>

None

M

M

M <len>

C <len>

Codabar

N <len>

None

N

N

N <len>

N <len>

Code 128

L <len>

None

K

K

K <len>

L <len>

I 2 of 5

I <len>

None

I

I

I <len>

I <len>

Code 93

None

None

L

L

L <len>

None

D 2 of 5

H <len>

None

H

H

H <len>

H <len>

UCC/EAN 128

L <len>

None

P

P

P <len>

L <len>

MSI

None

None

O

O

O <len>

None

Bookland EAN

F

F

A

A

A

F

Trioptic

None

None

None

None

None

None

Code 11

None

None

None

None

None

None

IATA

H<len>

None

H

H

None

None

Code 32

None

None

None

None

None

None

Product Reference Guide

35

Page 42

RS-232

RS-232 Host Types To select an RS-232 host interface, scan one of the following bar codes.

*Standard RS-232

ICL RS-232

RS-232 Wincor-Nixdorf Mode A

RS-232 Wincor-Nixdorf Mode B

RS-232 Olivetti ORS4500

RS-232 Omron

RS-232 OPOS

RS-232 Fujitsu

36

QuickScan® L

Page 43

RS-232 Host Parameters

Baud Rate Baud rate is the number of bits of data transmitted per second. Set the scanner's baud rate to match the baud rate setting of the host device. Otherwise, data may not reach the host device or may reach it in distorted form.

Baud Rate 600

Baud Rate 1200

Baud Rate 2400

Baud Rate 4800

*Baud Rate 9600

Baud Rate 19,200

Baud Rate 38,400

Product Reference Guide

37

Page 44

RS-232

Parity A parity check bit is the most significant bit of each ASCII coded character. Select the parity type according to host device requirements. •

Select Odd parity and the parity bit value is set to 0 or 1, based on data, to ensure that an odd number of 1 bits are contained in the coded character.

•

Select Even parity and the parity bit value is set to 0 or 1, based on data, to ensure that an even number of 1 bits are contained in the coded character.

•

Select Mark parity and the parity bit is always 1.

•

Select Space parity and the parity bit is always 0.

•

Select None when no parity bit is required.

Odd

Even

Mark

Space

*None

38

QuickScan® L