The text of a manual · part 6 of 25
QuickScan L QD 2300 Bar Code Scanner Product Reference Guide: General Features
Pages 25 to 36 of 192, from QuickScan L QD 2300 Bar Code Scanner Product Reference Guide
The original document is the PDF (3.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic QD-2300
Page 25
Chapter 5 General Features User Preferences User preferences for the general features listed in this chapter can be selected using the programming bar codes that accompany each feature description. To set feature values, scan a single programming bar code or a short bar code sequence as instructed for each feature. The settings are stored in non-volatile memory and are preserved even when the scanner is powered down. Typically, a scanner ships with the settings shown in User General Feature Defaults on page 20 (also see Appendix B, Standard Defaults for all host defaults). If the default values suit requirements, programming may not be necessary. If not using a USB cable, select a host type (see each host chapter for specific host information) after the power-up beeps sound. This is only necessary upon the first power-up when connecting to a new host. To return all features to their default values, reference the topic, Return to Factory Defaults. Throughout the programming bar code menus, default values are indicated with asterisks (*).
* Indicates Default
*High Frequency
Feature/Option
Scanning Sequence Examples In most cases, scanning one bar code sets the parameter value. For example, to set the beeper tone to high, scan the High Frequency (beeper tone) bar code on page 19. The scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry. Other parameters, such as Serial Response Time-Out or Data Transmission Formats, require the scanning of a sequence of bar codes. See these parameter descriptions for this procedure.
Errors While Scanning Unless otherwise specified, when an error is made during a scanning sequence, just rescan the correct feature bar code(s).
Product Reference Guide
19
Page 26
General Features
User General Feature Defaults Table 4 lists the factory defaults for the general features described in this chapter, plus provides a place for you to log any special requirements or user-preferred settings at your installation. To change any option, scan the appropriate programming bar code(s) provided in this chapter. See Appendix B, Standard Defaults for a listing of all programmable features. NOTE Table 4. General Feature Defaults General Feature
20
Standard Factory Default
Page Number
Beeper Tone
Medium
22
Beeper Volume
High
22
Power Mode
Continuous On
23
Scanning Mode
Trigger Single
23
Scan Line Width
Full Width
25
Laser On Time
3.0 Sec
25
Beep After Good Decode
Enable
26
Transmit Label ID Character
None
26
Prefix Value
7013 <CR><LF>
27
Suffix Value
7013 <CR><LF>
27
Scan Data Transmission Format
Data as is
26
FN1 Substitution Values
Set
30
Transmit “No Read” Message
Disable
30
Record Your Setting
QuickScan® L
Page 27
Default Parameters
Default Parameters The scanner can be reset using one of two default settings: factory defaults or custom defaults. Scan the appropriate bar code(s) below to reset the scanner to its default settings and/or set the scanner’s current settings as the custom default. Set Factory Defaults, Scan the Set Factory Defaults bar code below to eliminate all custom default values and return the scanner to factory default values. (For factory default values, see Appendix B, Standard Defaults.) Write to Custom Defaults, Custom default parameters can be configured to set unique default values for all parameters. After changing all parameters to the desired default values, scan the Write to Custom Defaults bar code below to configure custom defaults.
Restore Defaults Resets all default parameters as follows: •
If custom default values were configured (see Write to Custom Defaults above), the custom default values are set for all parameters each time the Restore Defaults bar code below is scanned.
•
If no custom default values were configured, the factory default values are set for all parameters each time the Restore Defaults bar code below is scanned. (For factory default values, see Appendix B, Standard Defaults.)
Set Factory Defaults
Write to Custom Defaults
*Restore Defaults
Product Reference Guide
21
Page 28
General Features
Beeper Tone To select a decode beep frequency (tone), scan the Low Frequency, Medium Frequency, or High Frequency bar code.
Low Frequency
*Medium Frequency (Optimum Settings)
High Frequency
Beeper Volume To select a beeper volume, scan the Low Volume, Medium Volume, or High Volume bar code.
Low Volume
Medium Volume
*High Volume
22
QuickScan® L
Page 29
Power Mode
Power Mode This parameter determines whether or not power remains on after a decode attempt. When in reduced power mode, the scanner enters low power consumption mode after each decode. When in continuous power mode, power remains on after each decode.
*Continuous On
Reduced Power Mode
Scan Mode This parameter determines whether the scanner is in Trigger Single Mode or Stand Mode. In Trigger Single Mode, the scanner trigger button must be pressed to decode each scanned bar code. In Stand Mode, the scanner laser is in constant ON state and no trigger button press is required to scan a bar code. Depending upon which mode the scanner currently is in, scan the “Toggle Scan Mode” to switch from Trigger Single to Stand Mode, or from Stand Mode to Trigger Single Mode. The standard default setting for this feature is Trigger Single Mode. While in the Stand Mode of operation, if the scanner has not been used for several minutes it will shift to low power operation, signalled by a narrowing of the scanning beam. When in low power mode, the scanner will respond to a barcode and come back to normal Stand Mode operation upon seeing/reading the label. If the scanner has been idle for an extended configurable period1, it will timeout, then enter sleep mode with the scanning beam turned off. To wake the scanner from sleep mode, press the trigger button.
*Toggle Scan Mode
1. See the following topic Stand Mode Timeout Period.
Product Reference Guide
23
Page 30
General Features
Stand Mode Timeout Period The Timeout Period for the transition from low power to sleep mode can be set to one of the following durations: •
1 Hour
•
5 Hours (default)
•
Infinite Timeout, With this setting, there is no timeout, thus the scanner will never go into sleep mode or beam shut-off but will remain in low power mode until a label is read.
Stand Mode Timeout Period = 1 Hour
*Stand Mode Timeout Period = 5 Hours
Stand Mode Timeout Period = Infinite Timeout
24
QuickScan® L
Page 31
Scan Line Width
Scan Line Width Scan a bar code below to set the scan line width. A full scan line width is the default. The medium scan line width is useful for scanning menus or pick-lists.
This feature applies to scanners in Trigger Single Mode only. NOTE
*Full Width
Medium Width
Laser On Time This parameter sets the maximum time that decode processing continues during a scan attempt. It is programmable in 0.1 second increments from 0.5 to 9.9 seconds. The default Laser On Time is 3.0 seconds. To set a Laser On Time, scan the bar code below. Next, scan the two numeric bar codes from Appendix E, Keypad, that correspond to the desired On Time. Single digit numbers must be padded with a leading zero. For example, to set an On Time of 0.5 seconds, scan the bar code below, then scan the “0” and “5” bar codes. If an error is made, or the selection needs to be changed, scan Cancel on page 166.
This feature applies to scanners in Trigger Single Mode only. NOTE
Laser On Time
Product Reference Guide
25
Page 32
General Features
Beep After Good Read Scan a bar code below to select whether or not the scanner should beep after a good read. If Do Not Beep After Good Read is selected, the beeper still operates during parameter menu scanning and indicates error conditions.
*Beep After Good Read (Enable)
Do Not Beep After Good Read (Disable)
Transmit Label ID Label ID characters identify the code (symbology) type of a scanned bar code. This may be useful when the scanner is decoding more than one code type. In addition to any single character prefix already selected, the Label ID character is inserted between the prefix and the decoded bar code. Select no Label ID character, a Datalogic Label ID, or an AIM Label ID. For a listing of Label ID Characters, see Datalogic Label ID Identifiers on page 157 and AIM Label ID Identifiers on page 157.
Datalogic Label ID
AIM Label ID
*No Label ID
26
QuickScan® L
Page 33
Prefix/Suffix Values
Prefix/Suffix Values A prefix and/or suffix can be appended to scan data for use in data editing as described in the feature description, Global Prefix/Suffix on page 28. To set a value for a prefix or suffix: 1. Change the scan data format using the instructions in the feature description, Global Prefix/Suffix on page 28. 2. Scan the appropriate prefix/suffix bar code below. 3. Scan a four-digit number (i.e., four bar codes from Appendix E, Keypad) that corresponds to that value.
NOTE
When using host commands to set the prefix or suffix, set the key category parameter to 1, then set the 3-digit decimal value corresponding to the desired keystroke as listed in Table 34 on page 167 (results in a four-digit ASCII code).
4. To correct an error or change a selection, scan Data Format Cancel on page 29.
Set Prefix
Set Suffix
Product Reference Guide
27
Page 34
General Features
Global Prefix/Suffix ASCII characters may be added as a prefix (in a position before the bar code data) and/ or as a suffix (in a position following the bar code data). Scan the bar code below labeled “Scan Options”, then one of the following four bar codes corresponding to the position(s) you wish to specify: •
Data As Is
•
<DATA> <SUFFIX>
•
<PREFIX> <DATA>
•
<PREFIX> <DATA> <SUFFIX>.
Scan the “Enter” bar code to complete the change. To set values for the prefix and/or suffix, See Prefix/Suffix Values on page 27. Scan the bar code “Data Format Cancel” if you wish to cancel the change. If a carriage return/enter is required after each scanned bar code, scan the following bar codes in order: 1. “Scan Options” 2. <DATA> <SUFFIX> 3. “Enter”
Scan Options
*Data As Is
<DATA> <SUFFIX>
28
QuickScan® L
Page 35
Global Prefix/Suffix
Global Prefix/Suffix, continued
<PREFIX> <DATA>
<PREFIX> <DATA> <SUFFIX>
Enter
Data Format Cancel
Product Reference Guide
29
Page 36
General Features
FN1 Substitution Values The Wedge and USB HID Keyboard hosts support an FN1 substitution feature. When enabled, any FN1 character (0x1b) in an EAN128 bar code is substituted with a value. This value defaults to 7013 (Enter Key). To select an FN1 substitution value via bar code menus: 1. Scan the bar code below.
*Set FN1 Substitution Value 2. Look up the keystroke desired for FN1 Substitution inAppendix F, ASCII Character Sets for the currently installed host interface. 3. Enter the 4-digit substitution value by scanning each digit in Appendix E, Keypad.
To correct an error or change the selection, scan Cancel. To enable FN1 substitution for keyboard wedge, scan the Enable FN1 Substitution on page 63. To enable FN1 Substitution for USB HID keyboard, scan the Enable FN1 Substitution on page 82.
Transmit “No Read” Message Scan a bar code below to select whether or not to transmit a No Read message. When enabled, the characters NR are transmitted when a bar code is not decoded. When disabled, if a bar code does not decode, nothing is sent to the host.
Enable No Read
*Disable No Read
30
QuickScan® L