Page 11

Getting Started

Select the desired interface by scanning the associated barcode below. INTERFACE

SELECTION BARCODE

RS-232 Standard RS-232 Wincor-Nixdorf RS-232 for OPOS/UPOS/ JavaPOS Wand Emulation IBM 46XX Port 5B IBM 46XX Port 9B

USB Coma

USB Keyboard

USB Alternate Keyboard

USB OEM a.

Download the correct USB Com driver from www.datalogic.com

Quick Reference Guide

9

Page 12

Interface selection, continued INTERFACE

SELECTION BARCODE

Keyboard AT Keyboard Wedge for PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Standard Key Encoding Keyboard AT-NK

Keyboard AT-ALT

Keyboard AT-ALT-NK

Keyboard Wedge for IBM AT PS2 with standard key encoding but without external keyboard

Keyboard Wedge for AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Alternate Key

Keyboard Wedge for IBM AT PS2 with alternate key encoding but without external keyboard

Keyboard XT Keyboard Wedge for PC/XT w/Standard Key Encoding Keyboard IBM 3153 Keyboard Wedge for IBM Terminal 3153 Keyboard IBM-M

10

Keyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make only keyboard

PowerScanTM PD7100 Corded

Page 13

Defaults INTERFACE

SELECTION BARCODE

Keyboard IBM-MB

Keyboard Wedge for IBM Terminals 31xx, 32xx, 34xx, 37xx make break keyboard

Keyboard DIG-VT Keyboard Wedge for DIGITAL Terminals VT2xx, VT3xx, VT4xx Keyboard USB-KBDApple

USB Keyboard for Apple computers

Defaults For your convenience, standard defaults are shown here for each of the major interface types. For more details or to change these settings, reference the Product Reference Guide (PRG). RS-232 Standard Default Settings, 9600 Baud, no Parity, 1 Stop Bit, Handshaking disabled, no Intercharacter Delay, Beep on ASCII BEL disabled, Beep On Not On File enabled, ACK Character = ‘ACK’, NAK Character = ‘NAK’, ACK NAK Timeout Value = 600ms, ACK NAK Retry Count = 3, ACK NAK Error Handling = Ignore, Indicate Transmission Failure enabled, Disable Reader Command = ‘D’, Enable Reader Command = ‘E’. Wand Emulation Standard Default Settings, Wand Idle State =

Low, Wand Polarity = Quiet Zones & Spaces High - Bars Low, No Label Symbology Conversion, Transmit Noise = Disabled. OEM/IBM Standard Default Settings, OEM-USB Device Usage

= Table Top Scanner, Transmit Labels in Code 39 Format = OEM Standard Format, 46xx Number of Host Resets = 6. USB Standard Default Settings, USB Keyboard Speed = Fast

(1ms).

Quick Reference Guide

11

Page 14

Keyboard Standard Default Settings (Keyboard AT), Country Mode = U.S., Caps Lock= OFF, Numlock Key =Unchanged, Send Control Characters = Disabled, Wedge Quiet Interval = 100ms, No Wedge Intercode Delay.

Resetting the Standard Product Defaults If programming settings for your reader are in an unknown condition, factory settings can be restored by scanning the “Factory Default Settings” barcode below. A listing of factory default settings is available in the PRG. Settings can vary, depending upon the interface type.

Factory Default Settings

Symbologies Symbologies are factory enabled or disabled in the reader as follows:

Enabled Symbologies •

UPC-A, UPC-E, EAN 13, EAN 8, without add-ons, Check Character Transmission enabled, no Expansion, Minimum Reads = 1 (except In-Store Minumum Reads = 2), System Number Transmission = enabled, 2D Components = disabled, EAN 8 Guard Insertion/Substitution Options = disabled (except EAN 8 Guard Substitution), Stitching = disabled.

•

Code 39, Check Character Calculation/Transmission enabled, Start/Stop Character disabled, Full ASCII disabled, Quiet Zones = auto, Minimum Reads = 1, Decoding Level and Aggressiveness = 3, Variable Length Control, Length One = 2, Length Two = 50, Interdigit Ratio = 4, Character Correlation = Disabled, Stitching is enabled.

•

Code 128, No Expansion, Check Character Transmission enabled, SubCode Change not transmitted, Quiet Zones = Auto, Minimum Reads = 1, Decoding Levels and Aggressiveness = 3,

12

PowerScanTM PD7100 Corded

Page 15

How to Scan

Variable Length Control, Length One = 1, Length two = 80, Character Correlation = disabled, Stitching = enabled. •

Interleaved 2 of 5, Zero Pattern and Check Character Calculation = disabled, Check Character Transmission = enabled, Minimum Reads = 1, Decoding Levels and Aggressiveness = 3, Variable Length Control, Length One = 12, Length Two = 100, Character Correlation and Stitching = disabled.

Disabled Symbologies GS1 DataBar (Omnidirectional, Expanded and Limited), GTIN formatting, Pharmacode 39, Codabar, Code 93, Code 11, Standard 2 of 5.

How to Scan When the trigger is pressed, the reader projects a red, horizontal illuminating beam. This beam will remain on until the trigger is released, a barcode is read, or until a time-out1 period expires.

NOTE

If the surface being scanned is highly reflective (e.g., laminated), it may be necessary to tilt the item or the reader slightly (15° to 18°) to prevent unwanted reflection.

Linear Barcodes, To scan a linear barcode, center the illumination beam over the barcode as shown in Figure 3. The reader must “see” across the width of all of the bars. Move the reader further away from the barcode to increase the scanning coverage area, and closer in to read very small barcodes.

1. Reference the Product Reference Guide (PRG) for more information about the aiming beam time-out period.

Quick Reference Guide

13

Page 16

Figure 3. Scanning Barcodes

Decrease...

(Green spot provides good read feedback)

...or Increase distance from barcode to adjust aiming beam width to cross all bars.

Troubleshooting The reader will automatically perform a set of self-tests whenever you turn it on. If your reader doesn’t seem to be functioning properly, follow these steps to try and isolate the problem. 1. Is the power on? Does the illumination beam come on? If no illumination beam, check that... • all connections are fully seated and in the appropriate port(s). • the host system power is on (if external power isn’t used). • the trigger works. 2. Is the reader having trouble reading your symbols? If the reader isn’t reading symbols well, check that the symbols... • aren’t smeared, rough, scratched, or exhibiting voids. • aren’t coated with frost or water droplets on the surface. • are enabled in the reader. See the Product Reference Guide (PRG) for more about configuring the reader to read symbologies.

14

PowerScanTM PD7100 Corded

Page 17

How to Scan

3. Is the barcode displayed but not entered? The barcode is displayed on the host device correctly, but you still have to press a key to enter it (the Enter/Return or Tab key, for example). You need to program a suffix which enables the reader to output the barcode data plus the key you need (such as a carriage return “CR”) to enter the data into your application. Refer to the PRG for further information. 4. Does the reader read the barcode incorrectly? If the reader reads a barcode, but the data is not displayed correctly on the host screen: • The reader may not be programmed for the appropriate terminal interface. For example, you scan “12345” and the host displays “@es%.” Reprogram the reader with the correct interface selection barcode. See Programming in this manual and/or the PRG. • The reader may not be programmed to output your barcode data properly. For example, you scan “12345” and the host displays “A12345B.” Reprogram the reader with the proper Data Editing selections. Reference the PRG. 5. The reader won’t read your barcode at all. • Scan the part number barcode in the back of this manual or the samples from the PRG. If the reader reads sample barcodes, check that your barcode is readable. • Verify that your barcode symbology is enabled. See the PRG. 6. If you aren’t sure what programming options have been set in the reader, or if you want the factory default settings restored, go to the Resetting the Standard Product Defaults section of this manual and scan the standard factory default settings barcode.

Quick Reference Guide

15

Page 18

Figure 4. Labeling and Nomenclature This illustration shows label placement ONLY. For actual regulatory, patent and other applicable information, view the labels on the product itself, or call your nearest sales or service office.

Scan Window

Trigger LASER RADIATION. DO NOT STARE INTO BEAM. 1mW, 635 - 670 nm Class 2 LASER PRODUCT DATALOGIC 959 Terry St. Eugene, OR 97402 USA

INPUT:

4-14VDC

Model: PD7100

S / N : B E TA 0 0 8 5

DATE: 2008-04-03

Class: PD7130-YB-PTR

S/N and Laser Safety Label Safety/EMC Marks Indicator LEDs Speaker Port

Interface (I/F) Cable

FOR LASER POINTER VERSION: COMPLIES WITH 21 CFR 1040.10 AND 1040.11 EXCEPT FOR DEVIATIONS PURSUANT TO LASER NOTICE NO. 50 DATED JUNE 24, 2007. IEC/EN60825-1:2007. SEE QRG FOR PATENT INFO. N263

16

PowerScanTM PD7100 Corded

Page 19

EUROPEAN DECLARATION OF CONFORMITY

Datalogic Scanning,lnc. hereby declares that the apparatus specified below has been tested and found compliant to the following European Council Directives and Hannonized Standards: Apparatus: PowerScan PD7100 family

Directives: EMC 2004/108/EC Low Voltage 2006/95/EC RoHS 2002/95/EC WEEE 2002/96/EC

Standards: EN 61000 6-4:2007

Generic Emissions, for Industrial environments CISPR 22:2006 Generic Emissions AN/NZS CISPR 22:2006 Generic Emissions EN 61000 6-2:2005 Generic Immunity, for Industrial environments (Includes EN61000-4-2 (ESD), 4-3 (Radiated Immunity) 4-4 (EFT), 4-5 (Surge), 4-6 (Cond Immunity) and 4-11 (Voltage dips/interruptions) EN 60950-1:2007 ITE Safety EN 60825-1:2007 Laser Safety EN 61000-3-2:2006 Harmonic Current EN 61000-3-3:1995+A1:2001+A2:2005 Voltage Fluctuation/Flicker

Equipment Type: Handheld Barcode Scanning Equipment Interface Protocol: RS-232, USB, Keyboard Wedge, IBM, Wand Emulation Placed into EU Service: July 2008 under the Datalogic logo. Responsible Manufacturer: Datalogic Scanning, Inc. 959 Terry St. Eugene, OR 97402 USA

July 18, 2008

Brad West Vice President Supply Chain Operations Datalogic Scanning, Inc.

Page 20

Australia

Japan

Datalogic Scanning Pty Ltd

Datalogic Scanning KK

Telephone: [61] (2) 9870 3200

Telephone: 81 (0)3 3491 6761 australia.scanning@datalogic.com japan.scanning@datalogic.com

France and Benelux

Latin America

Datalogic Scanning SAS

Datalogic Scanning, Inc

Telephone: [33].01.64.86.71.00

Telephone: (305) 591-3222 france.scanning@datalogic.com latinamerica.scanning@datalogic.com

Germany

Singapore

Datalogic Scanning GmbH

Datalogic Scanning Singapore PTE LTD

Telephone: 49 (0) 61 51/93 58-0

Telephone: (65) 6435-1311 germany.scanning@datalogic.com singapore.scanning@datalogic.com

India

Iberia

Datalogic Scanning India

Datalogic Scanning SAS Sucursal en España

Telephone: 91- 22 - 64504739

Telephone: 34 91 746 28 60 india.scanning@datalogic.com spain.scanning@datalogic.com

Italy

United Kingdom

Datalogic Scanning SpA

Datalogic Scanning LTD

Telephone: [39] (0) 39/62903.1

Telephone: 44 (0) 1582 464900 italy.scanning@datalogic.com uk.scanning@datalogic.com www.scanning.datalogic.com

Datalogic Scanning, Inc. 959 Terry Street Eugene, OR 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140

©2008 - 2011 Datalogic Scanning, Inc.

820032314 (Rev. B)

March / 2011