Page 15
DATALOGIC
Hz 0.5 0.6 0.75 0.85 1 1.5 2 2.5 3 4 5 7 10 14 20
OM4000
Max. Aperture
Extreme Angle Positions
40°
+ 20° - 20°
30° 24° 18°
+ 18° - 18°
NOTE: By limiting the raster width to the minimum necessary, the number of scans on the reading surface is increased.
2.5.2 Triggered Mode With this operating mode the oscillating mirror movement is stopped after the reading phase OFF signal (EXT TRIG becomes inactive) plus a fixed 5.3-second timeout. In low-throughput applications or applications with scheduled operating cycles, it is possible to extend the life of the oscillating mirror by limiting operation and therefore mechanical wear, to the specific time that barcodes are present in the reading area. The mirror begins movement again at the reading phase ON signal (EXT TRIG becomes active). NOTE: You must allow for the start-up time of the oscillator's motor (≈ 3 ms) and therefore position the system photocell to compensate for this time.
9
Page 16
OM4000
DATALOGIC less than 5.3 sec. EXT TRIG
Internal Timer
5.3 sec.
5.3 sec.
ON
Mirror movement
OFF t = motor startup ≈ 3 ms
Figure 10 - State diagram for Triggered mode
The EXT TRIG+ and EXT TRIG- inputs must be connected as well as the power VS and GND.
To use the OM4000 in this mode: 1. Set the MODE switch to Triggered. 2. Set the Frequency switch to 0 (setup). The mirror will toggle between the Min and Max positions aiding the configuration. 3. Set the Max Position switch to the correct value for your application. 4. Set the Min Position switch to the correct value for your application. 5. Set the Frequency switch to the desired value for your application between 1-F (triggered mode).
NOTE: The following limits apply to the Triggered Mode settings: The Min Position value must be less than the Max Position (2 switch positions).
10
Page 17
DATALOGIC
Hz 0.5 0.6 0.75 0.85 1 1.5 2 2.5 3 4 5 7 10 14 20
OM4000
Max. Aperture
Extreme Angle Positions
40°
+ 20° - 20°
30° 24° 18°
+ 18° - 18°
This mode is further signalled by the yellow Trigger LED. The LED is on when oscillation is stopped. The LED is OFF when the mirror is oscillating.
11
Page 18
OM4000
DATALOGIC
2.5.3 Fixed Mode Fixed mode allows you to position the laser beam at any angle between +20° and -20° with respect to the mounting position of the scanner. To use the OM4000 in this mode: 1. Set the Frequency switch to 0. 2. Set the Min Position switch to 0. 3. Set the Max Position switch to the correct value for your application between 1-F. (the laser will move to the value aiding the configuration) The MODE switch setting is indifferent.
Example:
FIXED MODE
MAX POSITION
4 = -12°
0 = disabled MIN POSITION
Figure 11
12
Page 19
OM4000
DATALOGIC
3 MAINTENANCE AND TROUBLESHOOTING OM4000 has no user replaceable components and, apart from periodically cleaning the output window, no particular maintenance is necessary; dust and dirt on the surface may alter the reading performance of the system. Clean the window with soft material and alcohol, absolutely avoiding all abrasive substances.
WARNING Do not remain in the laser beam output zone during these procedures.
If the device does not operate correctly, verify the power supply is present and the raster width setting is correct. If the red ERROR LED is on check the switch settings for correct operating mode configuration. Integrate the operating controls of the scanner with the above. Please consult your nearest Datalogic distributor if the problem persists after all the tests.
13
Page 20
OM4000
DATALOGIC
4 TECHNICAL FEATURES ELECTRICAL CHARACTERISTICS Operating voltage
10 to 30 Vdc
Input current
80 mA max without scanner
Raster width user adjustable from 0° to 40° (for further details see paragraph 2.5)
Oscillation frequency user adjustable from 0.5 Hz to 20 Hz (for further details see paragraph 2.5)
READING FEATURES See paragraph 2.4 and the scanner Installation manual
ENVIRONMENTAL FEATURES Operating temperature
0 °C/+40 °C (32 °F/104 °F)
Storage temperature
-20 °C/+70 °C (-4 °F to 158 °F)
Max. relative humidity
90% non condensing
Vibration Resistance
IEC 68-2-6 Test FC 1.5 mm; 10: 55 Hz; 2 hours x, y, z axis
Shock resistance
IEC 68-2-27 Test EA 30 G; 11 ms; 3 shocks x, y, z axis
Protection class
IP64 (when correctly mounted to the scanner)
PHYSICAL FEATURES Mechanical dimensions
74 x 101 x 58 mm (2.9 x 4.0 x 2.3 in.)
Weight approximately 600 g (21 oz)
Note: The features indicated are to be considered typical at an ambient temperature of 25 °C (77 °F), if not specified differently.
14
Page 21
DATALOGIC
OM4000
A READING DIAGRAMS EXAMPLE READING DIAGRAM DS4600-X10X 650
S ID E V IE W
+20°
690
+12°
R eading Zone
0° -12°
690
-20° 65 0 0
100
20 0
3 00
400
5 00
600
7 00 m m
200 150 T O P V IE W 100 50 0
±12° ±20°
50 1 00 15 0 200 mm
15