Page 15

DATALOGIC

Hz 0.5 0.6 0.75 0.85 1 1.5 2 2.5 3 4 5 7 10 14 20

OM4000

Max. Aperture

Extreme Angle Positions

40°

+ 20° - 20°

30° 24° 18°

+ 18° - 18°

NOTE: By limiting the raster width to the minimum necessary, the number of scans on the reading surface is increased.

2.5.2 Triggered Mode With this operating mode the oscillating mirror movement is stopped after the reading phase OFF signal (EXT TRIG becomes inactive) plus a fixed 5.3-second timeout. In low-throughput applications or applications with scheduled operating cycles, it is possible to extend the life of the oscillating mirror by limiting operation and therefore mechanical wear, to the specific time that barcodes are present in the reading area. The mirror begins movement again at the reading phase ON signal (EXT TRIG becomes active). NOTE: You must allow for the start-up time of the oscillator's motor (≈ 3 ms) and therefore position the system photocell to compensate for this time.

9

Page 16

OM4000

DATALOGIC less than 5.3 sec. EXT TRIG

Internal Timer

5.3 sec.

5.3 sec.

ON

Mirror movement

OFF t = motor startup ≈ 3 ms

Figure 10 - State diagram for Triggered mode

The EXT TRIG+ and EXT TRIG- inputs must be connected as well as the power VS and GND.

To use the OM4000 in this mode: 1. Set the MODE switch to Triggered. 2. Set the Frequency switch to 0 (setup). The mirror will toggle between the Min and Max positions aiding the configuration. 3. Set the Max Position switch to the correct value for your application. 4. Set the Min Position switch to the correct value for your application. 5. Set the Frequency switch to the desired value for your application between 1-F (triggered mode).

NOTE: The following limits apply to the Triggered Mode settings: The Min Position value must be less than the Max Position (2 switch positions).

10

Page 17

DATALOGIC

Hz 0.5 0.6 0.75 0.85 1 1.5 2 2.5 3 4 5 7 10 14 20

OM4000

Max. Aperture

Extreme Angle Positions

40°

+ 20° - 20°

30° 24° 18°

+ 18° - 18°

This mode is further signalled by the yellow Trigger LED. The LED is on when oscillation is stopped. The LED is OFF when the mirror is oscillating.

11

Page 18

OM4000

DATALOGIC

2.5.3 Fixed Mode Fixed mode allows you to position the laser beam at any angle between +20° and -20° with respect to the mounting position of the scanner. To use the OM4000 in this mode: 1. Set the Frequency switch to 0. 2. Set the Min Position switch to 0. 3. Set the Max Position switch to the correct value for your application between 1-F. (the laser will move to the value aiding the configuration) The MODE switch setting is indifferent.

Example:

FIXED MODE

MAX POSITION

4 = -12°

0 = disabled MIN POSITION

Figure 11

12

Page 19

OM4000

DATALOGIC

3 MAINTENANCE AND TROUBLESHOOTING OM4000 has no user replaceable components and, apart from periodically cleaning the output window, no particular maintenance is necessary; dust and dirt on the surface may alter the reading performance of the system. Clean the window with soft material and alcohol, absolutely avoiding all abrasive substances.

WARNING Do not remain in the laser beam output zone during these procedures.

If the device does not operate correctly, verify the power supply is present and the raster width setting is correct. If the red ERROR LED is on check the switch settings for correct operating mode configuration. Integrate the operating controls of the scanner with the above. Please consult your nearest Datalogic distributor if the problem persists after all the tests.

13

Page 20

OM4000

DATALOGIC

4 TECHNICAL FEATURES ELECTRICAL CHARACTERISTICS Operating voltage

10 to 30 Vdc

Input current

80 mA max without scanner

Raster width user adjustable from 0° to 40° (for further details see paragraph 2.5)

Oscillation frequency user adjustable from 0.5 Hz to 20 Hz (for further details see paragraph 2.5)

READING FEATURES See paragraph 2.4 and the scanner Installation manual

ENVIRONMENTAL FEATURES Operating temperature

0 °C/+40 °C (32 °F/104 °F)

Storage temperature

-20 °C/+70 °C (-4 °F to 158 °F)

Max. relative humidity

90% non condensing

Vibration Resistance

IEC 68-2-6 Test FC 1.5 mm; 10: 55 Hz; 2 hours x, y, z axis

Shock resistance

IEC 68-2-27 Test EA 30 G; 11 ms; 3 shocks x, y, z axis

Protection class

IP64 (when correctly mounted to the scanner)

PHYSICAL FEATURES Mechanical dimensions

74 x 101 x 58 mm (2.9 x 4.0 x 2.3 in.)

Weight approximately 600 g (21 oz)

Note: The features indicated are to be considered typical at an ambient temperature of 25 °C (77 °F), if not specified differently.

14

Page 21

DATALOGIC

OM4000

A READING DIAGRAMS EXAMPLE READING DIAGRAM DS4600-X10X 650

S ID E V IE W

+20°

690

+12°

R eading Zone

0° -12°

690

-20° 65 0 0

100

20 0

3 00

400

5 00

600

7 00 m m

200 150 T O P V IE W 100 50 0

±12° ±20°

50 1 00 15 0 200 mm

15