Manual · Datalogic
OM4000 Installation Manual
Manual21 pagesPDF 135 KB
Installation manual for the Datalogic OM4000 oscillating mirror, an accessory for the DS41, DS4300 and DS4600 laser scanners.
Covers · 1 model
The models it covers
Summary
What is in it
The installation manual for the Datalogic OM4000 oscillating mirror, an accessory that attaches to a 4000 series laser scanner (DS41, DS4300, DS4600) and deflects its beam so the scanner reads a surface instead of a line. It covers the mechanical dimensions, assembly to the scanner, the four-wire electrical connection to a C-Box or junction box, reading features, switch settings for oscillating, triggered and fixed modes, maintenance and troubleshooting, technical features and reading diagrams.
Its parts
- Introduction
- Installation
- Maintenance and Troubleshooting
- Technical Features
From the manual · read page by page
Key facts from this manual
Each line names its page in the PDF.
The installation manual (2000, marked preliminary) for the Datalogic OM4000 oscillating mirror, an accessory that turns the scan line of a DS41, DS4300 or DS4600 laser scanner into an adjustable raster. It covers mounting the mirror on the scanner, wiring, switch settings for the three operating modes, maintenance and technical features.
- Device
- Oscillating mirror accessory that deflects the scanner's laser beam into an adjustable raster p. 7
- Compatible scanners
- 4000 series laser scanners: DS41, DS4300, DS4600 p. 7
- Power
- 10 to 30 Vdc; 80 mA max input current without scanner; powered from the scanner's C-Box or junction box p. 7, 20
- Cable
- Four-wire cable from a compression connector, carrying VS, GND, EXT TRIG+ and EXT TRIG- p. 10
- Raster width
- User adjustable from 0° to 40°; factory set to 20° p. 13, 20
- Oscillation frequency
- User adjustable from 0.5 Hz to 20 Hz; factory set to 10 Hz p. 13, 20
- Operating modes
- Oscillating (always moving), Triggered (stops after the reading phase), Fixed (mirror at a set angle) p. 12
- Indicators
- Red ERROR LED (invalid switch settings); yellow TRIGGER LED (on when oscillation is stopped in Triggered mode) p. 12, 17
- Reading loss
- Reading features drop by about 10% in typical conditions through the mirror p. 11
- Size and weight
- 74 x 101 x 58 mm (2.9 x 4.0 x 2.3 in.); approximately 600 g (21 oz) p. 20
- Environment
- Operating 0 °C/+40 °C (32 °F/104 °F); storage -20 °C/+70 °C; 90% non condensing humidity p. 20
- Protection class
- IP64 when correctly mounted to the scanner p. 20
- Triggered timeout
- Mirror stops 5.3 seconds after the reading phase OFF signal; motor start-up about 3 ms p. 15
What this manual walks you through
- Mounting the mirror on the scanner with the long and short fixing screws p. 9
- Wiring the mirror to a C-Box or the scanner's junction box p. 10
- Opening the body to reach the configuration switches p. 12
- Setting raster angles and frequency with the switch tables p. 13
- Setting up Oscillating mode p. 14
- Setting up Triggered mode with the external trigger inputs p. 15, 16
- Setting up Fixed mode at one beam angle p. 18
- Cleaning the window and troubleshooting p. 19
Good to know
- Switch combinations not in the settings table are errors and turn on the red ERROR LED. p. 12
- In Oscillating and Triggered modes the Min Position must be below the Max Position; the note gives 2 switch positions. p. 14, 16
- Never use abrasive substances on the scanner window; clean it with soft material and alcohol. p. 8
- The OM4000 has no user replaceable components. p. 19
- In Triggered mode, allow for the motor start-up time when positioning the photocell. p. 15
Questions this manual answers
Which scanners does the Datalogic OM4000 oscillating mirror fit?
The 4000 series laser scanners: DS41, DS4300 and DS4600. p. 7
How do I connect the OM4000?
Its four-wire cable goes to the scanner's C-Box or junction box; Oscillating mode needs only VS and GND, Triggered mode also EXT TRIG+ and EXT TRIG-. p. 10, 14, 16
Why is the red ERROR LED on my OM4000 lit?
The configuration switches are set to a combination the settings table does not allow; check the switches for the chosen operating mode. p. 12, 19
What power does the OM4000 need?
10 to 30 Vdc, drawing 80 mA max without the scanner. p. 20
The whole text · 3 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file