2 INSTALLATION When opening the packaging, verify that the OM4000 oscillating mirror is complete with the installation manual and set of fixture screws. Check that the output window of the scanner is clean, otherwise clean with soft material and alcohol; all abrasive substances must be absolutely avoided as they cause irreparable damage to the transparency of the glass.

2.1 MECHANICAL DIMENSIONS The following figure gives the overall dimensions of the OM4000 and may be used for its installation.

Figure 1 - Overall dimensions

2

Page 9

DATALOGIC

OM4000

2.2 ASSEMBLY TO THE SCANNER

1)

Clean the mirror surface with a clean soft cloth and alcohol before assembling it to the scanner.

2)

Remove the two cover screws from the scanner on the side closest to the Laser beam output window (see figure Figure 2.)

3)

Align the OM4000 over the output window of the scanner and join the devices using the two long fixing screws supplied, tighten the screws (see figure Figure 3.)

4)

Figure 2

Figure 3

Turn the assembly over, insert and tighten the two short fixing screws (see figure Figure 4.)

Figure 4

3

Page 10

OM4000

DATALOGIC

2.3 ELECTRICAL CONNECTION The OM4000 has a four-wire cable that extends from the compression connector and allows connection to either a C-Box or the junction box of the scanner. The following signals must be connected: Wire Color Red Black Yellow Brown

Signal VS GND EXT TRIG+ EXT TRIG-

Function Power Supply + Power Supply External Trigger input + External Trigger input C-Box

Scanner connected to C-Box

Scanner with OM4000 OM4000 power and input directly from C-Box

System cables Scanner connected to Junction box

Junction Box

Scanner with OM4000 OM4000 power and input directly from Junction box

System cables

Figure 5 - OM4000 connections

4

Page 11

DATALOGIC

OM4000

2.4 READING FEATURES Furthermore, the reading features decrease by about 10% in typical conditions due to the optical signal passing through the output window of the OM4000 and the reflection on the mirror surface.

MAX POSITION

+20°

0°

-20° MIN POSITION

Figure 6 - OM4000 reading distance

5

Page 12

OM4000

DATALOGIC

2.5 ADJUSTMENT The OM4000 can be configured to operate in different modes by setting hardware switches located inside the oscillating mirror body. See the figure below. To access these switches you must remove the four cover screws shown in the figure below.

Figure 7 - Opening the OM4000 body for configuration

The following operating modes can be configured: •

Oscillating - mirror always oscillating (see par. 2.5.1).

•

Triggered - mirror stopped after reading phase off (see par. 2.5.2).

•

Fixed - mirror set to fixed angle (see par. 2.5.3).

The following table describes the allowable switch settings for OM4000 configuration. Operating Modes Switches

Oscillating

Triggered

Fixed

Mode Min Position Max Position Frequency

1 1-D 3-F 1-F

0 1-D 3-F 1-F indifferent 0 1-F 0

Table 1 - Allowable switch settings

Combinations other than those specified in the table are erroneous and will cause the red ERROR LED to turn on.

6

Page 13

DATALOGIC

OM4000

ERROR LED (red)

TRIGGER LED (yellow) TRIGGERED MODE OSCILLATING MODE

MIN POSITION

FREQUENCY MAX POSITION

Figure 8 - Configuration switches

The raster width of the OM4000 is adjustable between +20° and -20° with reference to center 0° (see Figure 6). The raster width is factory set to 20°. The oscillation frequency of the OM4000 mirror can be set between 0.5 and 20 Hz. The oscillating frequency is factory set to 10 Hz. Min and Max Position Switch Setting 1 2 3 4 5 6 7 8 9 A B C D E F

Angle in °

Frequency Switch Setting

Frequency in Hz

-20 -18 -15 -12 -9 -6 -3 0 3 6 9 12 15 18 20

1 2 3 4 5 6 7 8 9 A B C D E F

0.5 0.6 0.75 0.85 1 1.5 2 2.5 3 4 5 7 10 14 20

Table 2 - Raster width settings

Table 3 - Oscillating frequency setting

7

Page 14

OM4000

DATALOGIC

2.5.1 Oscillating Mode In Oscillating mode, the mirror is in continuous movement between the Min and Max position settings. It requires only the power inputs VS and GND to be connected. To use the OM4000 in this mode: 1. Set the MODE switch to Oscillating (default setting). 2. Set the Frequency switch to 0 (setup). The mirror will toggle between the Min and Max positions aiding the configuration. 3. Set the Max Position switch to the correct value for your application. 4. Set the Min Position switch to the correct value for your application. 5. Set the Frequency switch to the desired value for your application between 1-F (oscillating mode). Example: OSCILLATING MODE

MAX POSITION

F = 20° B = 9° MIN POSITION

Figure 9

NOTE: The following limits apply to the Oscillating Mode settings: The Min Position value must be less than the Max Position (2 switch positions).