Page 41
INSTALLATION
3 Double Power Supply Installation
2 nd
Power Unit max. 2 m.
120 Ohm
VSGND2
1
DS41
4
#x (up to 31)
2 7
! DS41
4 2
1
#1
DS41
4 2
CHASSIS
1
7
#0
7
14 MX4000
13 12 11
VSGND1 max. 1200 m.
TX485TX485+ SGND
MULTIDROP MULTIDROP + MULTIDROP GND SHIELD
120 Ohm st
1 Power Unit
Figure 25 - Double supply single cable (power+multidrop line+shield)
33
Page 42
MX4000
3 Observe the following rules cabling the peripheral devices: • • •
• •
• •
• • •
34
Minimum wire size 24AWG The power line has to be used only for bar code readers and their accessories (i. e. photocells). Wire dimensioning must be selected and checked in order to avoid voltage drops greater than 0.8 Volts. st MULTIDROP GND is connected to GND1 (1 Power Unit) to avoid excessive 485 common mode voltage (485 driver references are to be connected together to avoid failure). All scanner SGNDs are floating since they are internally connected to GND, (if connected together, ground loop problems can occur). Then GND1 and GND2 nd (2 Power Unit) must be connected together with MULTIDROP GND using the third wire inside multidrop cable. GND2 should not be connected to earth to avoid possible ground loop problems if GND1 is also connected. This situation could result in failure or unreliable multidrop behaviour. If GND2 cannot be disconnected from earth, you must not wire GND2 to MULTIDROP GND. However this is not completely reliable since the 485 reference for the second group of scanner(s) is connected to the first group only through the earth connection depends on the quality of earth ground. Cable Shield connected only to Multiplexer earth. We suggest using the single cable layout shown in Figure 25 (multidrop+power). If not possible the separate DC voltage Power Cable (VS-GND) must be handled as a signal cable (do not put it together with other power cables) and must lie down as near as possible to the multidrop cable (avoiding wide loops between them). Scanner’s chassis may be connected to earth (it isn’t mandatory). The maximum distance, end to end, of the multidrop line should not exceed 1200 meters. 120 Ohm termination resistance required only for baud rates higher than 19200.
Page 43
INSTALLATION
3 Multiple Power Supply Installation max. 2 m.
~
Vdc
1 ~
~
CHASSIS
Vdc
DS41
4
#x
2
(up to 31)
7
DS41
4
#1
2
1
7
Vdc
DS41
4
#0
2
1
7
120 Ohm max. 1200 m.
TX485TX485+ SGND three wires + shield 14 MULTIDROP MX4000
13 12 11
MULTIDROP + MULTIDROP GND SHIELD
120 Ohm Figure 26 – Three-wire shielded multidrop cable
The multiple power supply installation is valid for both opto-isolated and non-isolated RS485 interfaces.
35
Page 44
MX4000
3 Observe the following rules when cabling the peripheral devices: • • • • • •
3.8
Minimum wire size 24AWG. MULTIDROP GND must be connected only to Power supply GND to avoid excessive 485 common mode voltage (485 driver references are to be connected together to avoid failure). Cable Shield connected only to Multiplexer earth. Scanner’s chassis may be connected to earth (it isn’t mandatory). The maximum distance, end to end, of the multidrop line should not exceed 1200 meters. 120 Ohm termination resistance required only for baud rates higher than 19200.
CONNECTIONS TO AUXILIARY INTERFACE
The auxiliary serial interface is used exclusively for RS232 point to point connections. The parameters relative to the auxiliary interface (baud rate, data bits, etc.) can be defined using the Winhost utility program or Keyboard Mode programming or Host Mode programming. For more details refer to the section "Auxiliary Interface Menu" in the Help On Line of the WINHOST utility program. 1
2
6
3
7
4
8
5
9
Figure 27 - 9-pin male connector
Connection to the auxiliary interface is provided through the standard RS232 9-pin male connector with the following pinout: 9-pin connector pinout
36
Pin
Name
Function
1 2 3 4 5 6 7 8 9
N.C. RXAUX TXAUX N.C. SGND N.C. RTSAUX CTSAUX N.C.
not connected auxiliary input auxiliary output not connected signal ground not connected auxiliary handshake auxiliary handshake not connected
Page 45
INSTALLATION
3
MX4000 AUX 9 pin D-sub
USER INTERFACE 2
RXAUX
3
TXAUX
8
CTSAUX
7
RTSAUX
5
SGND
TXD RXD DTR DCD SGND
MAXIMUM LENGTH: 15 m RTS/CTS HARDWARE HANDSHAKING ENABLED Figure 28 - RS232 auxiliary interface connections
The RTSAUX and CTSAUX signals control data transmission and synchronize the connected devices. If the RTS/CTS handshaking protocol is enabled, the MX4000 activates the RTSAUX output to indicate a message is to be transmitted. The receiving unit activates the CTSAUX input to enable the transmission.
3.9 3.9.1
CONNECTIONS TO I/O Inputs
The signals relative to these sensors must be connected to the MX4000 via the proper internal connector J4 (see Figure 12), respecting the following connections: Input signals (J4) Pin
Name
Function
7 8 9 10 11 12 13 14
IN1+ IN1IN1 GND IN1 VS IN2+ IN2IN2 GND IN2 VS input 1 (+) input 1 (-) input 1 signal ground input 1 operating voltage input 2 (+) input 2 (-) input 2 signal ground input 2 operating voltage
An input signal can be driven by sensors with NPN or PNP output and is optoisolated to assure maximum disturbance immunity.
37
Page 46
MX4000
3 The electrical features are: maximum voltage applicable at input: 30 V. maximum current: 25 mA.
IN1 VS and IN2 VS and their relative ground references (IN1 GND, IN2 GND) supply power to the input signals from the MX4000 with the following characteristics: typical voltage: 12 V. maximum current: 50 mA. A debounce filter is implemented on both inputs: the nominal value of the delay is 5 ms. USER INTERFACE
MX4000
J4
10,14
IN VS
7,11
IN+
8,12
IN-
9,13
IN GND
V
Signal Ground
IN VS = IN1 VS or IN2 VS IN+ = IN1+ or IN2+ IN- = IN1- or IN2IN GND = IN1 GND or IN2 GND Figure 29 - Input connections with NPN input interface
38
Page 47
INSTALLATION
3 MX4000
J4
USER INTERFACE 10,14
IN VS
7,11
IN+
8,12
IN-
9,13
IN GND
V Signal
IN VS = IN1 VS or IN2 VS IN+ = IN1+ or IN2+ IN- = IN1- or IN2IN GND = IN1 GND or IN2 GND
Figure 30 - Input connections with PNP user interface
3.9.2
Outputs
The following pins are present on the connector J4 (see Figure 12) of the MX4000: Output signals Pin
Name
Function
1 2 3 4 5 6
OUT1+ OUT1OUT2+ OUT2OUT3+ OUT3- output1 (+) output1 (-) output2 (+) output2 (-) output3 (+) 1 output3 (-)
The electrical features are: VCE max. Collector current max. VCE saturation
40 Vdc 40 mA continuous; 130 mA pulsed 1V at 10 mA
39
Page 48
MX4000
3
MX4000
USER INTERFACE Vext 40 Vdc max
J4
1, 3, 5
SIGNAL+
2, 4, 6
SIGNAL-
SIGNAL+ = OUT1+, OUT2+ or OUT3+ SIGNAL- = OUT1-, OUT2- or OUT3-
Figure 31 - Open collector output connection
MX4000
USER INTERFACE Vext 40 Vdc max
J4
1, 3, 5
SIGNAL+
2, 4, 6
SIGNAL-
SIGNAL+ = OUT1+, OUT2+ or OUT3+ SIGNAL- = OUT1-, OUT2- or OUT3Figure 32 - Open emitter output connection
40
Page 49
INSTALLATION
3
3.10 TYPICAL LAYOUTS The typical layouts for MX4000 depend on the model and therefore the type of system in which it is installed. There are many possibilities, some of which are shown in the following paragraphs.
3.10.1
MX4000 Standard Serial Interface Layout
The MX4000 is connected to a Host using one of the Standard Serial Interfaces: RS232, RS485 Half-Duplex or Full-Duplex, or 20 mA C.L. Each scanner or other peripheral device, is connected to the MX4000 using the RS485 Multidrop line.
RS485 Aux. RS232 Control Station
Main/Bus MX4000
Host
Figure 33 - MX4000 standard serial interface multistation layout
41
Page 50
MX4000
3
Aux. RS232 Control Station
Main/Bus MX4000 Host Figure 34 - MX4000 standard serial interface multi-sided layout
3.10.2
MX4000 Profibus DP Layout
PROFIBUS DP Master
Profibus DP Slave node #1
Profibus DP Slave node #n
MX4000 Profibus DP Slave node #2
Figure 35 - MX4000 Profibus DP layout
42