The text of a manual · part 4 of 6
MX4000 Installation Manual, pages 31 to 40
Pages 31 to 40 of 57
The original document is the PDF (654 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic MX4000
Page 31
INSTALLATION
3
20 mA Current Loop Interface The MX4000 has two current generators (one for transmission and one for reception), allowing active and passive type connections. The terminals of the system cable must be connected to the following pins of connector J1 for 20 mA Current Loop communications: 20 mA Current Loop connection Pin
Name
Function
3 4 5 7 8 9 10
CLINCLIN+ DRVCLIN CLGND CLOUTCLOUT+ DRVCLOUT current loop input (-) current loop input (+) input current generator generator reference current loop output (-) current loop output (+) output current generator
MX4000 I = 20 mA
USER INTERFACE 10 DRVCLOUT 9 CLOUT+
J1 I = 20 mA
8
CLOUT-
7
CLGND
5
DRVCLIN
SGND
4 CLIN+ 3
CLIN-
7
CLGND SGND
MAXIMUM LENGTH: 300 m
Figure 17 - 20 mA C.L. active connections
23
Page 32
MX4000
3 MX4000
USER INTERFACE + 9
CLOUT+
8
CLOUT+
J1 4
CLIN+
3
CLIN-
MAXIMUM LENGTH: 300 m
Figure 18 - 20 mA C.L. passive connections
To select this interface type, follow the instructions in the section "Main Serial Interface Selection" of this paragraph (Figure 10).
24
Page 33
INSTALLATION
3.6.2
3
Profibus Interface
To function correctly you must select a valid Profibus DP address using the DIP switch found on the Profibus DP board. Set the address as a binary number on the DIP switch. Address 1 ON 1 2 3 4 5 6 7 8
Address 10 SW1 ON 1 2 3 4 5 6 7 8
ON = 1,
ON 1 2 3 4 5 6 7 8
OFF = 0 where: SW1= LSB and SW8= MSB
Address 20 ON
Figure 19 - Profibus DP address selection 1 2 3 4 5 6 7 8
Some example Profibus DP address selections are shown in the figure above: To connect MX4000 as a Profibus DP Slave, use a standard Siemens Profibus cable with a 9-pin male connector (see DIN 19245 part 1) and plug it into the 9-pin female socket on MX4000 front panel. The following table reports a brief description of the implemented Profibus signals: Pin 1 3 4 5 6 8 9
Name SHIELD RX/TX + CNTR + DGND VP (*) RX/TX CNTR -
Function shield receive/transmit positive voltage control positive voltage (optional) data ground supply voltage +5v receive/transmit negative voltage control negative voltage (optional)
(*) Signal is necessary only for stations at the end of the bus cable for line termination. Please refer to the Siemens Profibus documentation for specific details.
25
Page 34
MX4000
3
9 pin D-sub connector for Profibus
J1
J2 J3
J4
1 2 3 4 5 6 7 8 9 10 11 SHIELD 12 MULTIDROP GND 13 MULTIDROP+ 14 MULTIDROP1 2 3 4 1 LONWORKS2 A 1 2 3 4 2 LONWORKS2 CT 3 LONWORKS2 B 4 SHIELD 1 OUT1+ 2 OUT13 OUT2+ 4 OUT25 OUT3+ 6 OUT37 IN1+ 8 IN19 IN1 GND 10 IN1 VS 11 IN2+ 12 IN213 IN2 GND 14 IN2 VS
6 7 8 9
1 2 3 4 5
Figure 20 - Profibus pinout
26
1 LONWORKS1 A 2 LONWORKS1 CT 3 LONWORKS1 B 4 SHIELD
Page 35
INSTALLATION
3.6.3
3
InterBus-S Interface
For the InterBus-S interface to work correctly, jumper JP5 must be installed. See Figure 10. On the last unit of the InterBus network, connect K/11 to L/12 on the BUS OUT connector. BUS IN connector Screw or Description crimp B/1 DO1 A/2 /DO1 D/3 DI1 C/4 /DI1 E/5 GND -/6 PE
BUS OUT connector Screw or Description crimp G/7 DO2 F/8 /DO2 J/9 DI2 H/10 /DI2 K/11 GND L/12 RBST -/13 PE VCC
27
Page 36
MX4000
3
J1
J2
1 2 3 4 5 6 7 8 9 10 11 SHIELD 12 MULTIDROP GND 13 MULTIDROP+ 14 MULTIDROP1 2 3 4 1 LONWORKS2 A 2 LONWORKS2 CT 3 LONWORKS2 B 4 SHIELD 1 OUT1+ 2 OUT13 OUT2+ 4 OUT25 OUT3+ 6 OUT37 IN1+ 8 IN19 IN1 GND 10 IN1 VS 11 IN2+ 12 IN213 IN2 GND 14 IN2 VS
1 2 3 4
J3
J4
1 2 3 4 5 6
7 8 9 10 11 12 13
1 LONWORKS1 A 2 LONWORKS1 CT 3 LONWORKS1 B 4 SHIELD
BUS IN CONNECTOR
BUS OUT CONNECTOR
Figure 21- InterBus-S pinout
28
Page 37
INSTALLATION
3.7
3
CONNECTIONS TO PERIPHERAL DEVICES
3.7.1
Multidrop Line
The terminals of the system cable must be connected to the following pins of connector J1: Multidrop Device Connection Pin
Name
Function
12 13 14 11
MULTIDROP GND MULTIDROP + MULTIDROP SHIELD
RS485 reference ground RS485 + transmitted/received data RS485 - transmitted/received data cable shield
MX4000
DEVICES 12 MULTIDROP GND
J1
13 MULTIDROP + 14 MULTIDROP -
RS485REF RTX485+ RTX485-
MAXIMUM LENGTH: 1200 m
Figure 22 - Multidrop device connections
It is important to remember that the RS485 reference wire (MULTIDROP GND in the figures) must always be connected as shown to avoid communication problems. The common reference on this line is important because the MULTIDROP interface was designed to withstand on both inputs a voltage ranging from -7 V to +12 V: a higher voltage drop could damage drivers and receivers.
Grounding the Multidrop Line Several Datalogic scanners have a non-isolated RS485 interfaces. DS2100, DS41, DS4300, DS4600 have no optocoupler on the RS485 driver and the RS485 ground is connected to the general GND (negative power supply) but isolated from chassisearth.
29
Page 38
MX4000
3
CAUTION
Different considerations must be made for other devices having RS485 ground connected to GND and also to chassis (DS2200 and DS1100).
The following examples show correct connections to the Multidrop line when the RS485 interface is not isolated. Single Power Supply Installation max. 2 m.
1
DS41
4
#x (up to 31)
2
DS41
4
120 Ohm
7
2 1
#1
7
DS41
4 2
CHASSIS
1
#0
7 max. 1200 m.
TX485TX485+ SGND
14 MULTIDROP MX4000
13 MULTIDROP + 12
VS GND Power Supply
11
MULTIDROP GND SHIELD
120 Ohm
Figure 23 – Single cable (power+multidrop line+shield)
30
Page 39
INSTALLATION
3 max. 2 m.
1
DS41
4
#x (up to 31)
2
DS41
4
120 Ohm
7
2 1
#1
7
DS41
4 2
#0
1
7
TX485- max. 1200 m.
TX485+ SGND
CHASSIS
14 MX4000
13 12
VS GND Power supply
11
MULTIDROP MULTIDROP + MULTIDROP GND SHIELD
120 Ohm
Figure 24 – Separate cables (shielded multidrop cable and power line cable)
31
Page 40
MX4000
3 Observe the following rules when cabling the peripheral devices: • • •
• •
• • •
32
Minimum wire size 24AWG The power line has to be used only for bar code readers and their accessories (i. e. photocells). Wire dimensioning must be selected and checked in order to avoid voltage drops greater than 0.8 Volts. MULTIDROP GND must be connected only to Power supply GND to avoid excessive 485 common mode voltage (485 driver references are to be connected together to avoid failure). All scanner SGNDs must be floating (not connected to MULTIDROP GND) since they are internally connected to GND (if connected ground loop problems can occur). Cable Shield connected only to Multiplexer earth. We suggest using the single cable layout in Figure 23. If not possible the separate Power Cable (VS-GND) should be handled as a signal cable (do not put it together with other power cables) and should lie down as near as possible to the multidrop cable (avoiding wide loops between them). Scanner’s chassis may be connected to earth (it isn’t mandatory). The maximum distance, end to end, of the multidrop line should not exceed 1200 meters. 120 Ohm termination resistance required only for baud rates higher than 19200.