Page 21
INSTALLATION
3
Figure 4 - Inserting the wire
Figure 5 - MX4000 view
Figure 6 - Terminal block connector and base
13
Page 22
MX4000
3
3.4 3.4.1
MECHANICAL INSTALLATION Overall Dimensions
The figure below gives the overall dimensions of the MX4000 and its relative mounting holes and may be used for its installation.
Figure 7 - Overall dimensions
14
Page 23
INSTALLATION
3.4.2
3
Mounting MX4000
MX4000 can be mounted on a wall or a panel. To do this: 1) Open the device as described in paragraph 3.3. If necessary, using the two mounting holes inside the MX4000 as a pattern, mark the panel or the wall with an appropriate object and then drill two pilot holes in the panel or in the wall. 2) Align the device and insert two appropriate screws (M5 x 35 UNI 6107 or M5 x 40) with their washers and then screw them into the panel or the wall until tight (see Figure 8).
Figure 8 - Mounting MX4000
15
Page 24
MX4000
3
3.5
CONNECTIONS TO POWER SUPPLY
The MX4000 is powered by a voltage between 10 to 30 VDC. A power cable can be made using the 4-pin male connector provided with the package. V+
CHASSIS 3 2
1
V-
Figure 9 - Power supply connector on MX4000
To maintain conformity with CE directives, you must ground the Chassis pin.
3.6
CONNECTIONS TO HOST
MX4000 offers several different types of system connections to the Host. These are described in the following paragraphs.
3.6.1
Standard Serial Interface - Main
For the MX4000 Standard serial interface models, the following signals are available on the Main serial interface: RS232
RS485 HALF-DUPLEX
20 mA CURRENT LOOP
RS485 FULL-DUPLEX
MX4000 automatically recognizes which Main serial interface type is selected at each power on of the device. The parameters relative to the Main interface (baud rate, data bits, etc.) can be defined using the Winhost utility program or Keyboard Mode programming or Host Mode programming. For more details refer to the section "Main Interface Menu" in the Help On Line of the WINHOST utility program.
16
Page 25
INSTALLATION
3
Main Serial Interface Selection One of the following interface types can be selected to connect the main interface of the MX4000 to the host computer: RS232 20 mA CURRENT LOOP
RS485 HALF-DUPLEX RS485 FULL-DUPLEX
To select the interface type, position the jumper block as indicated in the following figure:
AUX
J8 J5
ANYBUS
JP5
PROFIBUS
J6
LONWORKS
J7 JP1
JP4
JP2 JP3
J2 J3
MAIN INTERFACE
J1
J4 MAIN INTERFACE
POWER SUPPLY
20 mA C.L.
RS232 RS485 HD (polled) RS485 FD (non-polled)
Figure 10 - Interface type selection
17
Page 26
MX4000
3
Standard Serial Interface Grounding Rules Shielding the communication cable is an effective way to protect against capacitive conduction and radiated interference, while the effect against noise due to inductive coupling is small. In any case, the shielding effect occurs only if the shield is grounded; otherwise the entire voltage of the shielded material will be floating and will not give protection against electrical noise. When installing the MX4000 in a large system, remember that a voltage drop may occur between ground connections made at distant points. This could be the undesirable effect of variable electromagnetic fields due, for instance, to the presence of engines, leakage currents, lightning or other sources. For long distances between the devices (about 50 meters, but this length depends widely on the environment), the voltage drop between ground connections can be 100 V or higher. If you ground the shield in several points the voltage drop across the shield will cause a current, increasing the noise on the signal wires. Therefore, to avoid damage to the device drivers and loss of system performance in general, the shield should be grounded at most in one point only. Since the shielding protection is more effective near to the ground connection, it is advisable to ground the shield where electric noise is higher. Typically this is done at the MX4000 device.
Bad shielding effect Good shielding effect Figure 11 - Shield grounding effect
18
Page 27
INSTALLATION
3
Pinout The terminals of the internal connectors are numbered as illustrated in Figure 12:
J1
J2 J3
J4
1 SHIELD 2 485GND 3 TX232 / TXRX485+ / CLIN4 RTS232 / TXRX485- / CLIN+ 5 DRVCLIN 6 SGND 7 CLGND 8 RX232 / RX485+ / CLOUT9 CTS232 / RX485- / CLOUT+ 10 DRVCLOUT 11 SHIELD 12 MULTIDROP GND 13 MULTIDROP+ 14 MULTIDROP1 2 3 4 1 LONWORKS1 A 2 LONWORKS1 CT 1 LONWORKS2 A 3 LONWORKS1 B 1 2 3 4 2 LONWORKS2 CT 4 SHIELD 3 LONWORKS2 B 4 SHIELD 1 OUT1+ 2 OUT13 OUT2+ 4 OUT25 OUT3+ 6 OUT37 IN1+ 8 IN19 IN1 GND 10 IN1 VS 11 IN2+ 12 IN213 IN2 GND 14 IN2 VS
Figure 12 - Standard Serial internal connector pinouts
The shield (J1 Pin 1) is provided to protect system cabling from electrical noise. To avoid ground loop problems, the shield must be connected to ground in one point only.
19
Page 28
MX4000
3
RS232 Interface The serial interface is used in this case for point to point connections; it handles communication with the host computer and allows both transmission of data and the configuration of the MX4000. The terminals of the system cable must be connected to the following pins of connector J1 for RS232 interface connection: RS232 connection Pin 3 4 6 8 9
Name TX232 RTS232 SGND RX232 CTS232
Function transmitted data request to send signal ground received data clear to send
MX4000
J1
USER INTERFACE 3
TX232
4
RTS232
8
RX232
9
CTS232
6
SGND
RXD DCD TXD DTR SGND
MAXIMUM LENGTH: 15 m RTS/CTS HARDWARE HANDSHAKING ENABLED Figure 13 - RS232 main interface connections
To select this interface type, follow the instructions in the section "Main Serial Interface Selection" of this paragraph (Figure 10).
20
Page 29
INSTALLATION
3
Figure 14 - RS232 control signals
The RTS232 and CTS232 signals control data transmission and synchronize the connected devices. If the RTS/CTS handshaking protocol is enabled, the MX4000 activates the RTS232 output to indicate a message is to be transmitted. The receiving unit activates the CTS232 input to enable the transmission.
RS485 Full-Duplex Interface The RS485 full-duplex interface is used for non-polled communication protocols in point to point connections over longer distances than those acceptable for RS232 communications or in electrically noisy environments. The terminals of the system cable must be connected to the following pins of connector J1 for RS485 non-polled communications: RS485 full-duplex connection Pin
Name
Function
2 3 4 8 9
485GND TXRX485+ TXRX485RX485+ RX485-
RS485 reference ground RS485 + transmitted data RS485 - transmitted data RS485 + received data RS485 - received data
21
Page 30
MX4000
3 MX4000
USER INTERFACE
J1
2
485GND
3
TXRX485+
4
TXRX485-
8
RX485+
9
RX485-
RS485REF RX485 TX485
MAXIMUM LENGTH: 1200 m
Figure 15 - RS485 full-duplex connections
To select this interface type, follow the instructions in the section "Main Serial Interface Selection" of this paragraph (Figure 10).
RS485 Half-Duplex Interface The terminals of the system cable must be connected to the following pins of connector J1 for RS485 polled communications: RS485 half-duplex connection Pin
Name
Function
2 3 4
485GND TXRX485+ TXRX485-
RS485 reference ground RS485 + transmitted/received data RS485 - transmitted/received data
MX4000
J1
MULTIPLEXER 2
485GND
3
TXRX485+
4
TXRX485-
RS485REF +RTX485 -RTX485
MAXIMUM LENGTH: 1200 m
Figure 16 - RS485 half-duplex connections
To select this interface type, follow the instructions in the section "Main Serial Interface Selection" of this paragraph (Figure 10).
22