Page 194

DRAGON™ D131/M131

USB DESCRIPTION USB-COM Handshaking

ACK/NACK Protocol FIFO Inter-character Delay (ms) RX Timeout (100 ms) Serial Trigger Lock USB-KBD Keyboard Nationality (not for USB-KBD-ALT-MODE)

Keyboard Nationality (IBM AT compatible only)

FIFO Delays USB Keyboard Speed

STRING disable RTS/CTS XON/XOFF RTS always ON disable enable disable enable disable enable

CE0 CE1 CE2 CE3 ER0 ER1 EC0 EC1 CK00 - CK99 CL00 - CL99 CR0 CR1ab

Belgian English French German Italian Spanish Swedish USA Japanese Russian (Latin) Russian (Cyrillic) Hungarian Slovenian, Croatian, Serbian (Latin) Romanian Czech Republic disable enable Inter-Character (ms) Inter-Code (s) normal fast

FJ7 FJ4 FJ2 FJ3 FJ1 FJ6 FJ5 FJ0 FJ8 FJ9 FJA FJB FJC FJD FJE EC0 EC1 CK00 - CK99 FG00 - FG99 UT10 UT01 a = Hex values representing an ASCII character from 00 to FE enabling the device trigger. b = HEX values representing an ASCII character from 00 to FE inhibiting the device trigger.

186

Page 195

HOST CONFIGURATION STRINGS

WEDGE DESCRIPTION Keyboard Nationality

Keyboard Nationality (IBM AT compatible only)

Caps Lock Caps Lock Auto-Recognition (IBM AT compatible only)

Num Lock Delays Control Character Emulation

Belgian English French German Italian Spanish Swedish USA Japanese Russian (Latin) Russian (Cyrillic) Hungarian Slovenian, Croatian, Serbian (Latin) Romanian Czech Republic caps Lock ON caps Lock OFF disable enable toggle num lock num lock unchanged Inter-Character (ms) Inter-Code (s) Ctrl + Shift + Key Ctrl + Key

STRING FJ7 FJ4 FJ2 FJ3 FJ1 FJ6 FJ5 FJ0 FJ8 FJ9 FJA FJB FJC FJD FJE FE1 FE0 FP0 FP1 FL1 FL0 CK00 - CK99 FG00 - FG99 FO0 FO1

PEN DESCRIPTION Operating Mode interpret (does not require $+ or $-) transparent (does not require $+ or $-) Minimum Output Pulse 200μs 400μs 600μs 800μs 1 ms 1.2 ms Conversion to Code 39 and disable conversion to Code 39 Code 128 (D series only) enable conversion to Code 39 enable conversion to Code 128 (M series only) Output Level normal inverted

STRING $] $[ DG0 DG1 DG2 DG3 DG4 DG5 DA0 DA1 DA2 DD0 DD1

187

Page 196

DRAGON™ D131/M131

PEN (continued) DESCRIPTION Idle Level Overflow normal inverted narrow overflow medium overflow wide overflow

Inter-block Delay (100 ms)

STRING DE0 DE1 DH0 DH1 DH2 CK00-CK99

NETWORK DESCRIPTION RS485 Network

Slave Address Range Network Baud Rate

Network Warning Message Transmission Warning Message Master Header

Master Terminator x=

188

Disable Network Enable RS485 Slave Enable RS485 Master Minimum Address Maximum Address 9600 19200 38400 not transmitted transmitted not transmitted transmitted no header one character two characters three characters four characters five characters six characters seven characters eight characters no terminator one character two characters three characters four characters Five characters six characters seven characters eight characters

Hex value from 00 to FE representing an ASCII character

STRING RZ0 RZ1 RZ2 JB0000-1999 JC0000-1999 JE0 JE1 JE2 JG0 JG1 JH0 JH1 JA00 JA01x JA02xx JA03xxx JA04xxxx JA05xxxxx JA06xxxxxx JA07xxxxxxx JA08xxxxxxxx JA10 JA11x JA12xx JA13xxx JA14xxxx JA15xxxxx JA16xxxxxx JA17xxxxxxx JA18xxxxxxxx

Page 197

HOST CONFIGURATION STRINGS

DATA FORMAT

NOT FOR PEN EMULATION INTERFACES DESCRIPTION Code Identifier disable Datalogic standard AIM standard custom

Custom Code Identifier Headers

Terminators no header one character two characters three characters four characters five characters six characters seven characters eight characters no terminator one character two characters three characters four characters five characters six characters seven characters eight characters

STRING EB0 EB1 EB2 EB3 EHabc EA00 EA01x EA02xx EA03xxx EA04xxxx EA05xxxxx EA06xxxxxx EA07xxxxxxx EA08xxxxxxxx EA10 EA11x EA12xx EA13xxx EA14xxxx EA15xxxxx EA16xxxxxx EA17xxxxxxx EA18xxxxxxxx a = ASCII character. b, c, x = HEX values representing an ASCII character. a = ASCII character of the DATALOGIC STANDARD Code Identifier from the table on page 71. b = Hex value of the first Custom Code Identifier character from 00 to FD; FF = disable Code Identifier c = Hex value of the second Custom Code Identifier character from 00 to FD; FF = disable second character of Custom Code Identifier x = Hex value from 00 to FE

189

Page 198

DRAGON™ D131/M131

DATA FORMAT (continued)

NOT FOR PEN EMULATION INTERFACES DESCRIPTION Code Length Tx

Field Adjustment

Field Adjustment Character Character Replacement

Address Stamping

Address Delimiter

Time Stamping

Time Stamping Delimiter not transmitted transmitted in variable-digit format transmitted in fixed 4-digit format disable right addition left addition right deletion left deletion disable character replacement first character replacement second character replacement third character replacement disable reader address stamping enable reader address stamping disable cradle address stamping enable cradle address stamping disable reader address delimiter enable reader address delimiter and select character disable cradle address delimiter enable cradle address delimiter and select character disable hour/minutes/seconds/month/day/year hour/minutes/seconds/day/month/year hour/minutes/seconds month/day/year day/month/year disable time stamping delimiter enable time stamping delimiter and select character

STRING EE0 EE1 EE2 EF0 EFa0d EFa1d EFa2d EFa3d EGe EO0 EO1afg EO2afg EO3afg RU0 RU1 RW0 RW1 RV0 RV1h RY0 RY1h IL0 IL1 IL2 IL3 IL4 IL5 IM0 IM1h a = ASCII character. d = a number from the Hex/Numeric Table e, f, g, h = HEX values representing an ASCII character a = ASCII character of the DATALOGIC STANDARD Code Identifier from the table on page 71. d = a number in the range 01-32 from the Hex/Numeric Table e = Hex value from 00 to FE f = Hex value of the character to be replaced from 00 to FE g = Hex value of the new character to insert from 00 to FE FF = replace with no new character (remove character)

h = a HEX value in the range from 00 - FE representing the ASCII character.

190

Page 199

HOST CONFIGURATION STRINGS

POWER SAVE DESCRIPTION Sleep State (only for D131 series)

disable enable

Enter Sleep Timeout (100 ms)

STRING BQ0 BQ1 BR00-BR99

READING PARAMETERS DESCRIPTION Trigger Type

Trigger Signal Trigger Click Trigger-off Timeout (s) FLASH ON (100 ms) FLASH OFF (100 ms) Reads per Cycle Safety Time (100 ms) Beeper Intensity

Beeper Tone

Beeper Type Beeper Length Good Read Spot Duration

Aiming System Cradle Beeper Intensity software trigger hardware trigger always on trigger active level trigger active pulse disable enable one read multiple reads very low intensity low intensity medium intensity high intensity tone 1 tone 2 tone 3 tone 4 monotone bitonal long short disable short medium long disabled enabled disable low intensity medium intensity high intensity

STRING BK0 BK1 BK3 BA0 BA1 Bc0 Bc1 BD00 - BD99 BB001 - BB099 BB101 - BB199 BC0 BC1 BE00 - BE99 BG0 BG1 BG2 BG3 BH0 BH1 BH2 BH3 BJ0 BJ1 BI0 BI1 BV0 BV1 BV2 BV3 Bj0 Bj1 JI0 JI1 JI2 JI3

191

Page 200

DRAGON™ D131/M131

DECODING PARAMETERS DESCRIPTION Ink-spread Overflow Control Interdigit Control TM

Puzzle Solver

Decoding Safety disable enable disable enable disable enable disable enable one read two reads three reads four reads

CODE SELECTION DESCRIPTION DISABLE ALL FAMILY CODES EAN/UPC disable EAN/UPC family EAN 8/EAN 13/UPC A/UPC E without ADD ON with ADD ON with and without ADD ON EAN 8/EAN 13 without ADD ON with ADD ON 2 ONLY with ADD ON 5 ONLY with ADD ON 2 AND 5 UPC A/UPC E without ADD ON with ADD ON 2 ONLY with ADD ON 5 ONLY with ADD ON 2 AND 5 EAN/UPC with and without Add On no Autodiscrimination EAN/UPC Autodiscrimination Add On by Prefix Select Prefixes cancel all selections 378/379 434/439 414/419 977 978 979 EAN 8 check digit transmission disable enable EAN 13 check digit transmission disable enable

192

STRING AX0 AX1 AW1 AW0 AV0 AV1 AU0 AU1 ED0 ED1 ED2 ED3

STRING AZ0 AA0 AA1 AA5 AA8 AA3 AAK AAL AA6 AA4 AAM AAN AA7 AA8Ad0 AA8Ad1 ET0 ET1378ET2379 ET3434ET4439 ET5414ET6419 ET7977 ET8978 ET9979 AAG0 AAG1 AAH0 AAH1

Page 201

HOST CONFIGURATION STRINGS

CODE SELECTION (continued) DESCRIPTION UPC A check digit transmission disable enable UPC E check digit transmission disable enable conversions UPC E to UPC A UPC E to EAN 13 UPC A to EAN 13 EAN 8 to EAN 13 ISBN Conversion codes enable ISBN enable ISSN enable ISBN and ISSN disable ISBN and ISSN Code 39 disable Code 39 family Standard no check digit control check digit control and transmission check digit control without transmission Full ASCII no check digit control check digit control and transmission check digit control without transmission CIP 39 Code 32 code length 2/5 disable Code 2/5 family Interleaved 2/5 no check digit control check digit control and transmission check digit control without transmission Normal 2/5 5 bars no check digit control check digit control and transmission check digit control without transmission Industrial 2/5 (IATA) no check digit control check digit control and transmission check digit control without transmission Matrix 2/5 3 bars no check digit control check digit control and transmission check digit control without transmission CIP/HR

STRING AAI0 AAI1 AAJ0 AAJ1 AAA AAB AAC AAD AP1 AP2 AP3 AP0 AB0 AB11 AB12 AB13 AB21 AB22 AB23 AB3 AB4 AB*xxxx AC0 AC11xxxx AC12xxxx AC13xxxx AC21xxxx AC22xxxx AC23xxxx AC31xxxx AC32xxxx AC33xxxx AC41xxxx AC42xxxx AC43xxxx AC5 xxxx = ASCII numbers that define the code length where: • •

First 2 digits = minimum acceptable code length. Second 2 digits = maximum acceptable code length.

The minimum code length must always be less than or equal to the maximum. The maximum code length for all codes is 99 characters: Examples: 0132 = variable length from 1 to 32 digits in the code. 1010 = 10 digit code length only.

193

Page 202

DRAGON™ D131/M131

CODE SELECTION (continued) DESCRIPTION Codabar disable Codabar family Standard no start/stop character equality control nor transmission no start/stop character equality control but transmission start/stop character equality control but no transmission start/stop character equality control and transmission ABC Codabar no start/stop character equality control but transmission Codabar ABC forced concatenation code length start/stop character case in transmission lower case upper case Code 128 disable Code 128 family enable Code 128 - control without transmission of check digit enable EAN 128 - control without transmission of check digit disable Transmit GS before Code enable ISBT 128 enable ISBT 128 code length Code 93 disable Code 93 family enable Code 93 - control without transmission of check digit MSI disable the family no check MOD10 no tx MOD10 with tx MOD11-MOD10 no tx MOD11-MOD10 with tx MOD10-MOD10 no tx MOD10-MOD10 with tx xxxx = ASCII numbers that define the code length where: • •

First 2 digits = minimum acceptable code length. Second 2 digits = maximum acceptable code length.

The minimum code length must always be less than or equal to the maximum. The maximum code length for all codes is 99 characters: EXAMPLES: 0132 = variable length from 1 to 32 digits in the code. 1010 = 10 digit code length only.

194

STRING AD0 AD111 AD112 AD121 AD122 AD212 AD232 AD*xxxx ADA0 ADA1 AI0 AI11 AI21 EQ0 EQ1 AI31 AILxxxx AK0 AK1 AE0 AE1 AE2 AE3 AE4 AE5 AE6 AE7

Page 203

HOST CONFIGURATION STRINGS

CODE SELECTION (continued) DESCRIPTION Code 11

Code 16K Code 49 RSS Codes disable the family no check Type C with tx Type C no tx Type K with tx Type K no tx Type C and K with tx Type C and K no tx disable enable disable enable disable the family disable RSS Expanded Linear and Stacked enable RSS Expanded Linear and Stacked disable RSS Limited enable RSS Limited disable RSS 14 Linear and Stacked enable RSS 14 Linear and Stacked

STRING AG0 AG1 AG21 AG22 AG31 AG32 AG41 AG42 AJ0 AJ1 AM0 AM1 AQ0 AQ10 AQ11 AQ20 AQ21 AQ30 AQ31

RADIO PARAMETERS DESCRIPTION Radio Protocol Timeout Power-Off Timeout Transmission Mode Beeper Control For Radio Response

Single Store

Find Me enable (seconds) one-way two-way normal only good decode only good reception off disable one attempt two attempts three attempts four attempts five attempts six attempts seven attempts eight attempts nine attempts disable enable

STRING RH02-RH19 RP00-RP99 RI0 RI1 BF0 BF1 BF2 BF3 RO0 RO1 RO2 RO3 RO4 RO5 RO6 RO7 RO8 RO9 Bk0 Bk1