Page 184

DRAGON™ D131/M131

7

TECHNICAL FEATURES

7.1

DRAGON™ D131

Electrical Features Supply Voltage Consumption @ 4V @ 5V @ 30 V Sleep Mode Indicators

4 to 30 Vdc 420 mA 310 mA 62 mA 4 mA Good Read LED (green) Good Read Spot (green), Beeper

Host Interfaces RS232

300 to 38400 baud

WEDGE

IBM AT or PS/2, XT, PC Notebook, IBM SURE1, IBM 3153, 31xx, 32xx, 34xx, 37xx terminals, Wyse terminals, Digital VT terminals, Apple ADB Bus supported

PEN Emulation USB

Laser Features Light Source Scan Rate Power (max) in mW Scan Angle PCS minimum (Datalogic Test Chart)

Resolution maximum Reading Field Width Laser Safety Class EN 60825-1 / CDRH

Selectable minimum pulse from 200 μS to 1.2 mS USB-KBD, USB-KBD-ALT-MODE, USB-KBD APPLE, USB-COM, USBIBM-Table Top, USB-IBM-Hand Held

D131 D131 LR VLD between 630~680 nm 35 ± 5 scans/sec 0.9 mW 1.4 mW 42° 23° 15%

40%

0.076 mm (3 mils) 0.25 mm (10 mils) see reading diagrams (par. 7.6) 2

Environmental Features Working Temperature Storage Temperature Humidity Drop resistance (on concrete) IEC 68-2-32 Test ED

Protection class

-30° to +50 °C / -22° to +122 °F -30° to +70 °C / -22° to +158 °F 90% non condensing 2m IP64

Mechanical Features Weight (without cable) Dimensions Cable length Material

176 about 295 g (10.4 oz) 205 x 114 x 69 mm (8.07 x 4.49 x 2.72 in) 2 m (6 ft 6 in) Polycarbonate molded with rubber

Page 185

TECHNICAL FEATURES

7.2

DRAGON™ M131

Electrical and General Features Battery Type Recharge Time Operating autonomy (continuous reading) Display (Only available with some models)

Indicators

Laser Features

2150 Li-Ion battery pack max. 4 hours with external power supply max 10 hours with Host power 60,000 reads (typical) LCD 4 lines x 16 chars Programmable font and backlight Good Read LED (green) Good Read Spot (green), Beeper M131 M131 LR

Light Source

VLD between 630~680 nm

Scan Rate

35 ± 5 scans/sec

Power (max) in mW Scan Angle PCS minimum (Datalogic Test Chart)

Resolution maximum Reading Field Width Laser Safety Class EN 60825-1 / CDRH

0.9 mW

1.4 mW

42°

23°

15%

40%

0.076 mm (3 mils)

0.25 mm (10 mils)

see reading diagrams (par. 7.6) 2

Environmental Features Working Temperature

-20° to +50 °C / -4° to +122 °F

Storage Temperature

-20° to +70 °C / -4° to +158 °F

Humidity Drop resistance (on concrete) IEC 68-2-32 Test ED

Protection Class

90% non condensing 2m IP64

Mechanical Features Weight (with batteries) Dimensions Material about 400 g (14.10 oz) 205 x 114 x 69 mm (8.07 x 4.49 x 2.72 in) (w/ display) 210 x 114 x 69 mm (8.27 x 4.49 x 2.72 in) Polycarbonate molded with rubber

177

Page 186

DRAGON™ D131/M131

7.3

OM-30X0 / C-3000 OM-30X0

C-3000

Electrical and General Features Supply Voltage External Power

10 to 30 Vdc

Host Power

5 Vdc ±10%

Power Consumption External Power Host Power Indicators max. 10 W (charging)* max. 500 mA (charging) Ext. Power /Data yellow LED Host Power/Data yellow LED Reader batt. state green/red LED Aux. batt. state green/red LED (OM-3000/C-3000 only) beeper

Recharge Time External Power max. 4 hours with 2150 mAh Li-Ion battery

Host Power max. 10 hours with 2150 mAh Li-Ion battery

Host Interfaces RS232

300 to 38400 baud

9600 baud

WEDGE

IBM AT or PS/2, XT, PC Notebook, IBM SURE1, IBM 3153, 31xx, 32xx, 34xx, 37xx terminals, Wyse terminals, Digital VT terminals, Apple ADB Bus supported

Not supported

PEN Emulation

Selectable minimum pulse from 200 μS to 1.2 mS

Not supported

USB

USB-KBD, USB-KBD-ALT-MODE, USBKBD APPLE, USB-COM, USB-IBM-Table Top, USB-IBM-Hand Held

USB-COM

Environmental Features Working Temperature

-20° to +50 °C / -4° to +122 °F**

Storage Temperature

-20° to +70 C / -4° to +158° F

Humidity

90% non condensing

Protection

IP40

Mechanical Features Weight without cable Dimensions (without antenna) Material about 380 g / 13.4 oz 204 x 108 x 95 mm / 9.44 x 4.25 x 3.74 in ABS

*

Having a switching regulator inside, the OM-30X0 and C-3000 draw the same power, regardless of the supply voltage. i.e. as the input voltage increases the current drawn decreases.

**

Batteries must be charged at a temperature ranging from 0° to +40 °C / +32° to +104 °F.

178

Page 187

TECHNICAL FEATURES

7.4

SYSTEM AND RADIO FEATURES

Radio Features

European Models

USA Models

Working Frequency

433.92 MHz

910 MHz

Bit Rate

19200

36800

Range (in open air)

50 m

30 m

OM-3000 model only

STARGATE™

32

255

System Configurations Maximum number of devices per base station Maximum number of devices in the same reading area Maximum number of base stations in network

7.5

2000 16 (including cradle Master)

STATUS INDICATORS

The reader has two indicator LEDs and a Beeper. The OM-3000 and C-3000 cradles have four LED indicators (three for OM-3010 model) and a Beeper. They signal several operating conditions which are described in the tables below. H = high tone

L = low tone

Dragon™ D131/M131 READER START-UP Beeper¹

Meaning

LLLL

Parameters loaded correctly

H H H H long tones HLHL

Parameter loading error, reading or writing error in the non volatile memory Hardware error in EEPROM

Dragon™ D131/M131 READER CONFIGURATION Beeper¹

Meaning

HHHH

Correct entry or exit from Configuration mode

L LLL

Good read of a command Command read error

179

Page 188

DRAGON™ D131/M131

Dragon™ D131/M131 READER DATA ENTRY Beeper¹

LED one beep²

ON

Good Read Spot Meaning

ON

H L long

Correct read of a code in normal mode TX buffer full (when FIFO is enabled) or TX error between Dragon™ M131 and OM-3000

H long

ON

ON

Successful advanced format concatenation

HHH

Timeout expired – operation not completed

H H long

Error in advanced data formatting OFF

OFF

Ready to read a code

¹ Only the Beeper Intensity command can modify these signals. ² The data entry good read tone is user-configurable with all the Beeper commands in the Reading Parameters section. For M-series readers, normally this results in two beeps; the first indicates that the reader has decoded the code, the second indicates whether OM-30X0 has received the data. See also par. 5.9.4. Dragon™ M131 POWER Beeper

LED

10 short H

10 short blinks

HML

Meaning

Low Battery Power off

H = high tone M = medium tone L = low tone Dragon™ M131 BIND, JOIN, COPY COMMANDS Beeper¹

LED

Blinking

Meaning

Command accepted; reader ready to be inserted into the cradle

L

Success

H L long tones

Failure

180

Page 189

TECHNICAL FEATURES

OM-30X0/C-3000 POWER/COMMUNICATION Aux LED

Host LED

Yellow

Yellow

OFF

OFF

ON

Meaning Device off Power applied through an external power supply

Flashing

ON

Power applied through the Host

Flashing

Transmission over the Host port

OM-30X0/C-3000 CHARGE STATUS Reader LED Red

Green

OFF

OFF

Beeper

Meaning No reader battery inserted

ON

Reader battery in charge ON single beep

Flashing orange

Reader battery completely charged Reader battery fault

Alternating red/green repetitive beep

Charging out of temperature range, overcurrent or over-voltage conditions

Alternating red/green every 30 seconds beep every 30 seconds

Reader not correctly inserted onto cradle, no charging takes place

Spare LED (not for OM-3010) Red

Green

OFF

OFF

Beeper

Meaning No Spare battery inserted in the SBS-3000 slot

ON

Spare battery in charge ON

Spare battery completely charged

Flashing orange

Spare battery fault

Alternating red/green repetitive beep

Charging out of temperature range, overcurrent or over-voltage conditions

Alternating red/green every 30 seconds beep every 30 seconds

Spare battery not correctly inserted into SBS3000, no charging takes place

181

Page 190

DRAGON™ D131/M131

7.6

READING DIAGRAMS DRAGON™ D/M131 12

24

36

48

60

72

84

96

108 cm

36

24

0.13 mm (5 mils)

12

0

12

0.19 mm (7.5 mils)

0.25 mm (10 mils)

24

0.33 mm (13 mils)

0.38 mm (15 mils)

0.50 mm (20 mils)

36 cm

1.00 mm (40 mils)

1.38 mm (55 mils)

DRAGON™ D/M131 LR 25

50

75

100

125

150

175

200

225 cm

75 1.00 mm (40 mils) 1.38 mm (55 mils) 50 25

0.25 mm (10 mils)

0

25

50

75 cm

182

0.38 mm 0.50 mm (15 mils) (20 mils) 1.00 mm (40 mils)

1.38 mm (55 mils)

Page 191

HOST CONFIGURATION STRINGS

A

HOST CONFIGURATION STRINGS

In this section we provide a description of how to modify the device configuration using serial strings sent from the Host. This method requires the RS232 interface. The device configuration can be changed by receiving commands from the Host through the serial interface. When this method is used, the programming sequence format is the following:

$+

Command

$-

CR Carriage return character (0D Hex.) Exit and Save configuration

Character sequence in following tables Enter configuration environment

Example: Multiple command programming sequence: $+

BG1 BH0

AC410132

$-

CR

Carriage return character (0D Hex.) Exit and save new configuration Matrix 2/5 3 bars: no check digit, variable length code from 1 to 32 characters Beeper tone 1 Beeper low intensity Enter configuration environment

Each configuration parameter setting removes the condition previously active for that parameter.

NOTE

The device buffer can contain about 400 characters. If your programming string goes over this value, you must split it into separate groups and send each group after a delay of at least 3 seconds to give the reader time to empty the buffer and interpret the commands.

183

Page 192

DRAGON™ D131/M131

SERIAL CONFIGURATION STRINGS SPECIAL CONFIGURATION COMMANDS DESCRIPTION Enter Configuration Exit and Save Configuration Restore Default Transmit Software Release (not for PEN emulation) Transmit Device Configuration in ASCII (not for PEN emulation) Set Custom Default Restore Custom Default

STRING $+ $$+$* $+$! $+$& $+$0 $+$1

These commands do not require $-.

INTERFACE SELECTION DESCRIPTION RS232 Standard ICL Mode Fujitsu Nixdorf Mode A WEDGE for IBM AT for IBM Terminals: 31xx, 32xx, 34xx, 37xx; make-break keyboard for IBM Terminals: 31xx, 32xx, 34xx, 37xx; make-only keyboard Keyboard Type for IBM Terminals 31xx, typewriter 32xx, 34xx, 37xx advanced for IBM XT for IBM Terminal 3153 for IBM PC Notebook for IBM SURE1 for IBM AT - ALT mode for IBM PC Notebook - ALT mode for Wyse Terminal - ANSI Keyboard for Wyse Terminal - PC Keyboard for Wyse Terminal - ASCII Keyboard for Wyse Terminal - VT220 style Keyboard for Digital Terminals VT2xx/3xx/4xx for Apple ADB Bus PEN EMULATION USB USB-KBD USB-KBD-ALT-MODE USB-KBD-APPLE USB-COM USB-IBM-Table Top USB-IBM-Hand Held

184

STRING CP0 CM0 CM1 CM2EC0 CP500 CP501 CP502 FK0 FK1 CP503 CP504 CP505 CP506 CP507 CP508 CP509 CP510 CP511 CP514 CP512 CP513 CP6 UA03 UA04 UA05 UA02 UA00 UA01

Page 193

HOST CONFIGURATION STRINGS

RS232 DESCRIPTION Baud Rate

300 600 1200 2400 4800 9600 19200 38400 Parity none even odd Data Bits 7 8 9 Stop Bits 1 2 Handshaking disable RTS/CTS XON/XOFF RTS always On ACK/NACK Protocol disable enable FIFO disable enable Inter-character Delay (ms) RX Timeout (100 ms) Serial Trigger Lock disable enable and select characters

STRING CD1 CD2 CD3 CD4 CD5 CD6 CD7 CD8 CC0 CC1 CC2 CA0 CA1 CA2 CB0 CB1 CE0 CE1 CE2 CE3 ER0 ER1 EC0 EC1 CK00 - CK99 CL00 - CL99 CR0 CR1ab a = Hex values representing an ASCII character from 00 to FE enabling the device trigger. b = HEX values representing an ASCII character from 00 to FE inhibiting the device trigger.

185