Page 184
DRAGON™ D131/M131
7
TECHNICAL FEATURES
7.1
DRAGON™ D131
Electrical Features Supply Voltage Consumption @ 4V @ 5V @ 30 V Sleep Mode Indicators
4 to 30 Vdc 420 mA 310 mA 62 mA 4 mA Good Read LED (green) Good Read Spot (green), Beeper
Host Interfaces RS232
300 to 38400 baud
WEDGE
IBM AT or PS/2, XT, PC Notebook, IBM SURE1, IBM 3153, 31xx, 32xx, 34xx, 37xx terminals, Wyse terminals, Digital VT terminals, Apple ADB Bus supported
PEN Emulation USB
Laser Features Light Source Scan Rate Power (max) in mW Scan Angle PCS minimum (Datalogic Test Chart)
Resolution maximum Reading Field Width Laser Safety Class EN 60825-1 / CDRH
Selectable minimum pulse from 200 μS to 1.2 mS USB-KBD, USB-KBD-ALT-MODE, USB-KBD APPLE, USB-COM, USBIBM-Table Top, USB-IBM-Hand Held
D131 D131 LR VLD between 630~680 nm 35 ± 5 scans/sec 0.9 mW 1.4 mW 42° 23° 15%
40%
0.076 mm (3 mils) 0.25 mm (10 mils) see reading diagrams (par. 7.6) 2
Environmental Features Working Temperature Storage Temperature Humidity Drop resistance (on concrete) IEC 68-2-32 Test ED
Protection class
-30° to +50 °C / -22° to +122 °F -30° to +70 °C / -22° to +158 °F 90% non condensing 2m IP64
Mechanical Features Weight (without cable) Dimensions Cable length Material
176 about 295 g (10.4 oz) 205 x 114 x 69 mm (8.07 x 4.49 x 2.72 in) 2 m (6 ft 6 in) Polycarbonate molded with rubber
Page 185
TECHNICAL FEATURES
7.2
DRAGON™ M131
Electrical and General Features Battery Type Recharge Time Operating autonomy (continuous reading) Display (Only available with some models)
Indicators
Laser Features
2150 Li-Ion battery pack max. 4 hours with external power supply max 10 hours with Host power 60,000 reads (typical) LCD 4 lines x 16 chars Programmable font and backlight Good Read LED (green) Good Read Spot (green), Beeper M131 M131 LR
Light Source
VLD between 630~680 nm
Scan Rate
35 ± 5 scans/sec
Power (max) in mW Scan Angle PCS minimum (Datalogic Test Chart)
Resolution maximum Reading Field Width Laser Safety Class EN 60825-1 / CDRH
0.9 mW
1.4 mW
42°
23°
15%
40%
0.076 mm (3 mils)
0.25 mm (10 mils)
see reading diagrams (par. 7.6) 2
Environmental Features Working Temperature
-20° to +50 °C / -4° to +122 °F
Storage Temperature
-20° to +70 °C / -4° to +158 °F
Humidity Drop resistance (on concrete) IEC 68-2-32 Test ED
Protection Class
90% non condensing 2m IP64
Mechanical Features Weight (with batteries) Dimensions Material about 400 g (14.10 oz) 205 x 114 x 69 mm (8.07 x 4.49 x 2.72 in) (w/ display) 210 x 114 x 69 mm (8.27 x 4.49 x 2.72 in) Polycarbonate molded with rubber
177
Page 186
DRAGON™ D131/M131
7.3
OM-30X0 / C-3000 OM-30X0
C-3000
Electrical and General Features Supply Voltage External Power
10 to 30 Vdc
Host Power
5 Vdc ±10%
Power Consumption External Power Host Power Indicators max. 10 W (charging)* max. 500 mA (charging) Ext. Power /Data yellow LED Host Power/Data yellow LED Reader batt. state green/red LED Aux. batt. state green/red LED (OM-3000/C-3000 only) beeper
Recharge Time External Power max. 4 hours with 2150 mAh Li-Ion battery
Host Power max. 10 hours with 2150 mAh Li-Ion battery
Host Interfaces RS232
300 to 38400 baud
9600 baud
WEDGE
IBM AT or PS/2, XT, PC Notebook, IBM SURE1, IBM 3153, 31xx, 32xx, 34xx, 37xx terminals, Wyse terminals, Digital VT terminals, Apple ADB Bus supported
Not supported
PEN Emulation
Selectable minimum pulse from 200 μS to 1.2 mS
Not supported
USB
USB-KBD, USB-KBD-ALT-MODE, USBKBD APPLE, USB-COM, USB-IBM-Table Top, USB-IBM-Hand Held
USB-COM
Environmental Features Working Temperature
-20° to +50 °C / -4° to +122 °F**
Storage Temperature
-20° to +70 C / -4° to +158° F
Humidity
90% non condensing
Protection
IP40
Mechanical Features Weight without cable Dimensions (without antenna) Material about 380 g / 13.4 oz 204 x 108 x 95 mm / 9.44 x 4.25 x 3.74 in ABS
*
Having a switching regulator inside, the OM-30X0 and C-3000 draw the same power, regardless of the supply voltage. i.e. as the input voltage increases the current drawn decreases.
**
Batteries must be charged at a temperature ranging from 0° to +40 °C / +32° to +104 °F.
178
Page 187
TECHNICAL FEATURES
7.4
SYSTEM AND RADIO FEATURES
Radio Features
European Models
USA Models
Working Frequency
433.92 MHz
910 MHz
Bit Rate
19200
36800
Range (in open air)
50 m
30 m
OM-3000 model only
STARGATE™
32
255
System Configurations Maximum number of devices per base station Maximum number of devices in the same reading area Maximum number of base stations in network
7.5
2000 16 (including cradle Master)
STATUS INDICATORS
The reader has two indicator LEDs and a Beeper. The OM-3000 and C-3000 cradles have four LED indicators (three for OM-3010 model) and a Beeper. They signal several operating conditions which are described in the tables below. H = high tone
L = low tone
Dragon™ D131/M131 READER START-UP Beeper¹
Meaning
LLLL
Parameters loaded correctly
H H H H long tones HLHL
Parameter loading error, reading or writing error in the non volatile memory Hardware error in EEPROM
Dragon™ D131/M131 READER CONFIGURATION Beeper¹
Meaning
HHHH
Correct entry or exit from Configuration mode
L LLL
Good read of a command Command read error
179
Page 188
DRAGON™ D131/M131
Dragon™ D131/M131 READER DATA ENTRY Beeper¹
LED one beep²
ON
Good Read Spot Meaning
ON
H L long
Correct read of a code in normal mode TX buffer full (when FIFO is enabled) or TX error between Dragon™ M131 and OM-3000
H long
ON
ON
Successful advanced format concatenation
HHH
Timeout expired – operation not completed
H H long
Error in advanced data formatting OFF
OFF
Ready to read a code
¹ Only the Beeper Intensity command can modify these signals. ² The data entry good read tone is user-configurable with all the Beeper commands in the Reading Parameters section. For M-series readers, normally this results in two beeps; the first indicates that the reader has decoded the code, the second indicates whether OM-30X0 has received the data. See also par. 5.9.4. Dragon™ M131 POWER Beeper
LED
10 short H
10 short blinks
HML
Meaning
Low Battery Power off
H = high tone M = medium tone L = low tone Dragon™ M131 BIND, JOIN, COPY COMMANDS Beeper¹
LED
Blinking
Meaning
Command accepted; reader ready to be inserted into the cradle
L
Success
H L long tones
Failure
180
Page 189
TECHNICAL FEATURES
OM-30X0/C-3000 POWER/COMMUNICATION Aux LED
Host LED
Yellow
Yellow
OFF
OFF
ON
Meaning Device off Power applied through an external power supply
Flashing
ON
Power applied through the Host
Flashing
Transmission over the Host port
OM-30X0/C-3000 CHARGE STATUS Reader LED Red
Green
OFF
OFF
Beeper
Meaning No reader battery inserted
ON
Reader battery in charge ON single beep
Flashing orange
Reader battery completely charged Reader battery fault
Alternating red/green repetitive beep
Charging out of temperature range, overcurrent or over-voltage conditions
Alternating red/green every 30 seconds beep every 30 seconds
Reader not correctly inserted onto cradle, no charging takes place
Spare LED (not for OM-3010) Red
Green
OFF
OFF
Beeper
Meaning No Spare battery inserted in the SBS-3000 slot
ON
Spare battery in charge ON
Spare battery completely charged
Flashing orange
Spare battery fault
Alternating red/green repetitive beep
Charging out of temperature range, overcurrent or over-voltage conditions
Alternating red/green every 30 seconds beep every 30 seconds
Spare battery not correctly inserted into SBS3000, no charging takes place
181
Page 190
DRAGON™ D131/M131
7.6
READING DIAGRAMS DRAGON™ D/M131 12
24
36
48
60
72
84
96
108 cm
36
24
0.13 mm (5 mils)
12
0
12
0.19 mm (7.5 mils)
0.25 mm (10 mils)
24
0.33 mm (13 mils)
0.38 mm (15 mils)
0.50 mm (20 mils)
36 cm
1.00 mm (40 mils)
1.38 mm (55 mils)
DRAGON™ D/M131 LR 25
50
75
100
125
150
175
200
225 cm
75 1.00 mm (40 mils) 1.38 mm (55 mils) 50 25
0.25 mm (10 mils)
0
25
50
75 cm
182
0.38 mm 0.50 mm (15 mils) (20 mils) 1.00 mm (40 mils)
1.38 mm (55 mils)
Page 191
HOST CONFIGURATION STRINGS
A
HOST CONFIGURATION STRINGS
In this section we provide a description of how to modify the device configuration using serial strings sent from the Host. This method requires the RS232 interface. The device configuration can be changed by receiving commands from the Host through the serial interface. When this method is used, the programming sequence format is the following:
$+
Command
$-
CR Carriage return character (0D Hex.) Exit and Save configuration
Character sequence in following tables Enter configuration environment
Example: Multiple command programming sequence: $+
BG1 BH0
AC410132
$-
CR
Carriage return character (0D Hex.) Exit and save new configuration Matrix 2/5 3 bars: no check digit, variable length code from 1 to 32 characters Beeper tone 1 Beeper low intensity Enter configuration environment
Each configuration parameter setting removes the condition previously active for that parameter.
NOTE
The device buffer can contain about 400 characters. If your programming string goes over this value, you must split it into separate groups and send each group after a delay of at least 3 seconds to give the reader time to empty the buffer and interpret the commands.
183
Page 192
DRAGON™ D131/M131
SERIAL CONFIGURATION STRINGS SPECIAL CONFIGURATION COMMANDS DESCRIPTION Enter Configuration Exit and Save Configuration Restore Default Transmit Software Release (not for PEN emulation) Transmit Device Configuration in ASCII (not for PEN emulation) Set Custom Default Restore Custom Default
STRING $+ $$+$* $+$! $+$& $+$0 $+$1
These commands do not require $-.
INTERFACE SELECTION DESCRIPTION RS232 Standard ICL Mode Fujitsu Nixdorf Mode A WEDGE for IBM AT for IBM Terminals: 31xx, 32xx, 34xx, 37xx; make-break keyboard for IBM Terminals: 31xx, 32xx, 34xx, 37xx; make-only keyboard Keyboard Type for IBM Terminals 31xx, typewriter 32xx, 34xx, 37xx advanced for IBM XT for IBM Terminal 3153 for IBM PC Notebook for IBM SURE1 for IBM AT - ALT mode for IBM PC Notebook - ALT mode for Wyse Terminal - ANSI Keyboard for Wyse Terminal - PC Keyboard for Wyse Terminal - ASCII Keyboard for Wyse Terminal - VT220 style Keyboard for Digital Terminals VT2xx/3xx/4xx for Apple ADB Bus PEN EMULATION USB USB-KBD USB-KBD-ALT-MODE USB-KBD-APPLE USB-COM USB-IBM-Table Top USB-IBM-Hand Held
184
STRING CP0 CM0 CM1 CM2EC0 CP500 CP501 CP502 FK0 FK1 CP503 CP504 CP505 CP506 CP507 CP508 CP509 CP510 CP511 CP514 CP512 CP513 CP6 UA03 UA04 UA05 UA02 UA00 UA01
Page 193
HOST CONFIGURATION STRINGS
RS232 DESCRIPTION Baud Rate
300 600 1200 2400 4800 9600 19200 38400 Parity none even odd Data Bits 7 8 9 Stop Bits 1 2 Handshaking disable RTS/CTS XON/XOFF RTS always On ACK/NACK Protocol disable enable FIFO disable enable Inter-character Delay (ms) RX Timeout (100 ms) Serial Trigger Lock disable enable and select characters
STRING CD1 CD2 CD3 CD4 CD5 CD6 CD7 CD8 CC0 CC1 CC2 CA0 CA1 CA2 CB0 CB1 CE0 CE1 CE2 CE3 ER0 ER1 EC0 EC1 CK00 - CK99 CL00 - CL99 CR0 CR1ab a = Hex values representing an ASCII character from 00 to FE enabling the device trigger. b = HEX values representing an ASCII character from 00 to FE inhibiting the device trigger.
185