Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 16 of 25

Dragon D131/M131 Reference Manual: 4 CONFIGURATION, pages 132 to 141

Pages 132 to 141 of 212, from Dragon D131/M131 Reference Manual

The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Datalogic MBC-3000

Page 132

Exit and Save Configuration

ADVANCED FORMATTING

Ì$-?Î

Field 5 Terminators no field terminators

ÌHH0bÎ 1 field terminator

2 field terminators

ÌHH1eÎ

ÌHH2hÎ

Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 00-FE. For Wedge and USB-KBD interface, it is also possible to read the Special Key(s) on page 75.

7

First Additional Fixed Field no fixed field

ÌHI0dÎ 1 character fixed field

ÌHI1gÎ 2 character fixed field

ÌHI2jÎ 3 character fixed field

ÌHI3mÎ 4 character fixed field

ÌHI4pÎ 5 character fixed field

124

Page 133

Exit and Save Configuration

Ì$-?Î

ADVANCED FORMATTING

ÌHI5sÎ 6 character fixed field

ÌHI6vÎ After selecting one of the Additional Fixed Field codes, read the corresponding character(s) from the HEX table. Range of characters = 00-FE. For Wedge and USB-KBD interface, it is also possible to read the Special Key(s) on page 75. Example: 4 Character Fixed Field

+ 4D + 41 + 49 + 4E =

8

MAIN

Second Additional Fixed Field no fixed field

ÌHJ0fÎ 1 character fixed field

ÌHJ1iÎ 2 character fixed field

ÌHJ2lÎ 3 character fixed field

ÌHJ3oÎ 4 character fixed field

125

Page 134

Exit and Save Configuration

ADVANCED FORMATTING

Ì$-?Î

ÌHJ4rÎ 5 character fixed field

ÌHJ5uÎ 6 character fixed field

ÌHJ6xÎ After selecting one of the Additional Fixed Field codes, read the corresponding character(s) from the HEX table. Range of characters = 00-FE. For Wedge and USB-KBD interface, it is also possible to read the Special Key(s) on page 75. Example: 3 Character Fixed Field

+ 53 + 45 + 54 =

9

SET

Field Transmission number of fields to transmit

ÌHK8Î Read one number in the range 1 to 7 for the number of fields to transmit. Include only fields to be transmitted. Field Order Transmission Read the codes corresponding to the fields to transmit in the order in which they are to be transmitted. A field can be transmitted more than once. See example. field 1

Ì12Î field 2

Ì23Î field 3

126

Page 135

Exit and Save Configuration

Ì$-?Î

ADVANCED FORMATTING

Ì34Î field 4

Ì45Î field 5

Ì56Î additional field 1

Ì67Î additional field 2

Ì78Î Example: The barcode is divided into 3 defined fields plus 1 additional fixed field. Transmit in the order: Field 2, Additional Field 1, Field 1, Field 2. Number of Fields to Transmit

Field 2

+4+

10

Additional Field 1

+

Field 1

+

Field 2

+

Standard Formatting do not apply standard formatting

ÌHL0jÎ apply standard formatting

ÌHL1mÎ DRAGON™ D: After performing Advanced Formatting on the barcode read, Standard Formatting (Headers, Code Length, Code ID, Terminators) can be applied to the message to be transmitted. DRAGON™ M: After performing Advanced Formatting on the barcode read, Standard Formatting (Code Length, Code ID) can be applied to the message to be transmitted.

11

End Format Definition

127

Page 136

Exit and Save Configuration

ADVANCED FORMATTING end Format 1 definition

ÌHM0lÎ end Format 2 definition

ÌHM1oÎ end Format 3 definition

ÌHM2rÎ end Format 4 definition

ÌHM3uÎ

128

Ì$-?Î

Page 137

Enter Configuration

Ì$+;Î

Exit and Save Configuration

ADVANCED FORMATTING

Ì$-?Î

Enable Advanced Format ‹ no Advanced Formats enabled

ÌHN0nÎ Advanced Format 1 enable

ÌHN11NÎ disable

ÌHN10JÎ Advanced Format 2 enable

ÌHN21QÎ disable

ÌHN20MÎ Advanced Format 3 enable

ÌHN31TÎ disable

ÌHN30PÎ Advanced Format 4 enable

ÌHN41WÎ disable

ÌHN40SÎ

129

Page 138

Enter Configuration

Ì$+;Î

Exit and Save Configuration

ADVANCED FORMATTING

Ì$-?Î

No Match Result clear data - no transmission

ÌHO0pÎ transmit data using standard format

ÌHO1sÎ This selection determines the action to be taken when codes read do not conform to the advanced format requisites (no match). •

Codes not matching can be ignored, cleared from memory and not transmitted.

•

Codes not matching can be transmitted using the Standard formatting (Headers, Code Length, Code ID, Terminators).

130

Page 139

RADIO PARAMETERS Dragon™ M131 Series readers only

~

~

RADIO PROTOCOL TIMEOUT POWER-OFF TIMEOUT TRANSMISSION MODE

~

BEEPER CONTROL FOR RADIO RESPONSE

~

~

SINGLE STORE BATCH MODE FIND ME

~

~ ~

~ ~

~ ~

~ ~

1.

Read the Enter Configuration code ONCE, available at the top of each page.

2.

Read configuration codes from the desired groups. = Read the code and follow the procedure given

3.

Read the Exit and Save Configuration code ONCE, available at the top of each page.

131

Page 140

Enter Configuration

Ì$+;Î

Exit and Save Configuration

RADIO PARAMETERS

Ì$-?Î

RADIO PROTOCOL TIMEOUT radio protocol timeout

ÌRH<Î Read a number from the table where: 02-19 = timeout from 2 to 19 seconds

‹ 2 seconds See par. 5.9.1 for details.

POWER-OFF TIMEOUT power-off timeout

ÌRPLÎ Read 2 numbers in the range 00-99: 00 = 01-99 =

Power-off disabled; reader always ready corresponds to a max. 99 hour delay before power-off.

‹ power-off after 4 hours. See par. 5.9.2 for details.

132

Page 141

Enter Configuration

Exit and Save Configuration

Ì$+;Î

Ì$-?Î

RADIO PARAMETERS

TRANSMISSION MODE ‹ One Way

ÌRI0nÎ Two-ways

ÌRI1qÎ See par. 5.9.3 for details.

BEEPER CONTROL FOR RADIO RESPONSE ‹ normal

ÌBF0XÎ only good decode

ÌBF1[Î only good reception

ÌBF2^Î off

ÌBF3aÎ See par. 5.9.4 for details.

133