The text of a manual · part 16 of 25
Dragon D131/M131 Reference Manual: 4 CONFIGURATION, pages 132 to 141
Pages 132 to 141 of 212, from Dragon D131/M131 Reference Manual
The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Datalogic MBC-3000
Page 132
Exit and Save Configuration
ADVANCED FORMATTING
Ì$-?Î
Field 5 Terminators no field terminators
ÌHH0bÎ 1 field terminator
2 field terminators
ÌHH1eÎ
ÌHH2hÎ
Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 00-FE. For Wedge and USB-KBD interface, it is also possible to read the Special Key(s) on page 75.
7
First Additional Fixed Field no fixed field
ÌHI0dÎ 1 character fixed field
ÌHI1gÎ 2 character fixed field
ÌHI2jÎ 3 character fixed field
ÌHI3mÎ 4 character fixed field
ÌHI4pÎ 5 character fixed field
124
Page 133
Exit and Save Configuration
Ì$-?Î
ADVANCED FORMATTING
ÌHI5sÎ 6 character fixed field
ÌHI6vÎ After selecting one of the Additional Fixed Field codes, read the corresponding character(s) from the HEX table. Range of characters = 00-FE. For Wedge and USB-KBD interface, it is also possible to read the Special Key(s) on page 75. Example: 4 Character Fixed Field
+ 4D + 41 + 49 + 4E =
8
MAIN
Second Additional Fixed Field no fixed field
ÌHJ0fÎ 1 character fixed field
ÌHJ1iÎ 2 character fixed field
ÌHJ2lÎ 3 character fixed field
ÌHJ3oÎ 4 character fixed field
125
Page 134
Exit and Save Configuration
ADVANCED FORMATTING
Ì$-?Î
ÌHJ4rÎ 5 character fixed field
ÌHJ5uÎ 6 character fixed field
ÌHJ6xÎ After selecting one of the Additional Fixed Field codes, read the corresponding character(s) from the HEX table. Range of characters = 00-FE. For Wedge and USB-KBD interface, it is also possible to read the Special Key(s) on page 75. Example: 3 Character Fixed Field
+ 53 + 45 + 54 =
9
SET
Field Transmission number of fields to transmit
ÌHK8Î Read one number in the range 1 to 7 for the number of fields to transmit. Include only fields to be transmitted. Field Order Transmission Read the codes corresponding to the fields to transmit in the order in which they are to be transmitted. A field can be transmitted more than once. See example. field 1
Ì12Î field 2
Ì23Î field 3
126
Page 135
Exit and Save Configuration
Ì$-?Î
ADVANCED FORMATTING
Ì34Î field 4
Ì45Î field 5
Ì56Î additional field 1
Ì67Î additional field 2
Ì78Î Example: The barcode is divided into 3 defined fields plus 1 additional fixed field. Transmit in the order: Field 2, Additional Field 1, Field 1, Field 2. Number of Fields to Transmit
Field 2
+4+
10
Additional Field 1
+
Field 1
+
Field 2
+
Standard Formatting do not apply standard formatting
ÌHL0jÎ apply standard formatting
ÌHL1mÎ DRAGON™ D: After performing Advanced Formatting on the barcode read, Standard Formatting (Headers, Code Length, Code ID, Terminators) can be applied to the message to be transmitted. DRAGON™ M: After performing Advanced Formatting on the barcode read, Standard Formatting (Code Length, Code ID) can be applied to the message to be transmitted.
11
End Format Definition
127
Page 136
Exit and Save Configuration
ADVANCED FORMATTING end Format 1 definition
ÌHM0lÎ end Format 2 definition
ÌHM1oÎ end Format 3 definition
ÌHM2rÎ end Format 4 definition
ÌHM3uÎ
128
Ì$-?Î
Page 137
Enter Configuration
Ì$+;Î
Exit and Save Configuration
ADVANCED FORMATTING
Ì$-?Î
Enable Advanced Format ‹ no Advanced Formats enabled
ÌHN0nÎ Advanced Format 1 enable
ÌHN11NÎ disable
ÌHN10JÎ Advanced Format 2 enable
ÌHN21QÎ disable
ÌHN20MÎ Advanced Format 3 enable
ÌHN31TÎ disable
ÌHN30PÎ Advanced Format 4 enable
ÌHN41WÎ disable
ÌHN40SÎ
129
Page 138
Enter Configuration
Ì$+;Î
Exit and Save Configuration
ADVANCED FORMATTING
Ì$-?Î
No Match Result clear data - no transmission
ÌHO0pÎ transmit data using standard format
ÌHO1sÎ This selection determines the action to be taken when codes read do not conform to the advanced format requisites (no match). •
Codes not matching can be ignored, cleared from memory and not transmitted.
•
Codes not matching can be transmitted using the Standard formatting (Headers, Code Length, Code ID, Terminators).
130
Page 139
RADIO PARAMETERS Dragon™ M131 Series readers only
~
~
RADIO PROTOCOL TIMEOUT POWER-OFF TIMEOUT TRANSMISSION MODE
~
BEEPER CONTROL FOR RADIO RESPONSE
~
~
SINGLE STORE BATCH MODE FIND ME
~
~ ~
~ ~
~ ~
~ ~
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups. = Read the code and follow the procedure given
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.
131
Page 140
Enter Configuration
Ì$+;Î
Exit and Save Configuration
RADIO PARAMETERS
Ì$-?Î
RADIO PROTOCOL TIMEOUT radio protocol timeout
ÌRH<Î Read a number from the table where: 02-19 = timeout from 2 to 19 seconds
‹ 2 seconds See par. 5.9.1 for details.
POWER-OFF TIMEOUT power-off timeout
ÌRPLÎ Read 2 numbers in the range 00-99: 00 = 01-99 =
Power-off disabled; reader always ready corresponds to a max. 99 hour delay before power-off.
‹ power-off after 4 hours. See par. 5.9.2 for details.
132
Page 141
Enter Configuration
Exit and Save Configuration
Ì$+;Î
Ì$-?Î
RADIO PARAMETERS
TRANSMISSION MODE ‹ One Way
ÌRI0nÎ Two-ways
ÌRI1qÎ See par. 5.9.3 for details.
BEEPER CONTROL FOR RADIO RESPONSE ‹ normal
ÌBF0XÎ only good decode
ÌBF1[Î only good reception
ÌBF2^Î off
ÌBF3aÎ See par. 5.9.4 for details.
133