Page 122

Exit and Save Configuration

ADVANCED FORMATTING

Ì$-?Î

Define the timeout, which determines the valid waiting period between the two codes, in order to accept concatenation. If the timeout expires, the resulting action will be based on the following selection. (HHDII)

5

Transmission after Timeout no code transmitted after timeout

ÌEM0iÎ only code 1 transmitted (if read) after timeout

ÌEM1lÎ only code 2 transmitted (if read) after timeout

ÌEM2oÎ either code 1 or code 2 transmitted after timeout

ÌEM3rÎ

114

Page 123

ADVANCED FORMATTING

ADVANCED FORMATTING Advanced formatting has been designed to offer you complete flexibility in changing the format of barcode data before transmitting it to the host system. This formatting will be performed when the barcode data meets certain criteria, which you will define in the following procedure. Up to 4 advanced code management formats can be defined and saved in memory. For each format you must complete the entire configuration procedure: Read the Enter Configuration Command Step 1 Begin Format Definition 1, 2, 3, or 4 Steps 2 - 4 Define Match Code Conditions Step 5 Divide Code into Fields Step 6 Define Code Fields Steps 7 - 8 Add up to 2 Additional Fields Step 9 Define Field Transmission Step 10 Apply or Not Standard Message Formatting Step 11 End Format Definition 1, 2, 3, or 4 YES

Define another? NO

Enable Advanced Formats 1, 2, 3, 4 Define No Match Result Read the Exit and Save Configuration Command

115

Page 124

Enter Configuration

Ì$+;Î 1

Exit and Save Configuration

ADVANCED FORMATTING

Ì$-?Î

Begin Format Definition begin Format 1 definition

ÌHA0TÎ begin Format 2 definition

ÌHA1WÎ begin Format 3 definition

ÌHA2ZÎ begin Format 4 definition

ÌHA3]Î 2

Match Code Type match code type

ÌHB&Î Read the above code + the code type to match from the Code Identifier Table in Appendix B. OR any code type

ÌHB0VÎ 3

Match Code Length match code length

ÌHC(Î Read the above code + two numbers in the range 01 to 99 for the exact code length. OR any code length

ÌHC001Î 116

Page 125

Exit and Save Configuration

ADVANCED FORMATTING 4

Ì$-?Î

Match with Predefined Characters no match

ÌHD0HE00ÄÎ OR match with 1 character

ÌHD1]Î match with a 2-character string

ÌHD2`Î match with a 3-character string

ÌHD3cÎ match with a 4-character string

ÌHD4fÎ After selecting the predefined match code, read the character(s) from the HEX table. Range of characters = 00-FE. Example: Match code with the 2-character predefined string = "@@". Match with a 2-character string

Read AND

+ 40 + 40 position of first character in predefined string

ÌHE,Î

117

Page 126

Exit and Save Configuration

ADVANCED FORMATTING

Ì$-?Î

Read the above code + two numbers in the range 01 to 99 representing the character position in the code where the first character of the predefined string must be found. Read 00 if the match string can be found in any character position. See par. 5.8.1 for details.

5

Divide Code into Fields divide code into fields

ÌHF.Î Read one number in the range 1 to 5 to divide the code into fields.

6

Define Code Fields define code fields

Each code field length can be set by either: a) defining a field separator character to be found in the code itself. In this case you can choose to discard the code separator character or include it as the last character of the field. OR BY b) defining a match character to be found consecutively repeated in the code itself. In this case the field ends with the first character that does not match. OR BY c) specifying a specific character length up to the maximum of 99 characters. OR BY d) selecting the last field as variable length (if any).

You must define the same number of fields as selected in step 5, including fields that will not be transmitted.

118

Page 127

Exit and Save Configuration

ADVANCED FORMATTING

Ì$-?Î

DEFINE FIELD 1 BY: EITHER field separator

ÌHG0`Î a)

Read the field separator character from the HEX table. Range of characters = 00-FE. discard separator include separator

Ì01Î

Ì12Î OR match character

ÌHG3iÎ b)

Read the match character from the HEX table. Range of characters = 00-FE. OR field length

ÌHG1cÎ c)

Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length)

ÌHG2fÎ d)

AND Field 1 Terminators no field terminators

ÌHH0bÎ 1 field terminator

2 field terminators

ÌHH1eÎ

ÌHH2hÎ

119

Page 128

Exit and Save Configuration

ADVANCED FORMATTING

Ì$-?Î

Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 00-FE. For Wedge and USB-KBD interface, it is also possible to read the Special Key(s) on page 75.

DEFINE FIELD 2 BY: EITHER field separator

ÌHG0`Î a)

Read the field separator character from the HEX table. Range of characters = 00-FE. discard separator include separator

Ì01Î

Ì12Î OR match character

ÌHG3iÎ b)

Read the match character from the HEX table. Range of characters = 00-FE. OR field length

ÌHG1cÎ c)

Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length)

ÌHG2fÎ d)

AND Field 2 Terminators no field terminators

ÌHH0bÎ 1 field terminator

120

2 field terminators

Page 129

Exit and Save Configuration

ADVANCED FORMATTING

ÌHH1eÎ

Ì$-?Î ÌHH2hÎ

Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 00-FE. For Wedge and USB-KBD interface, it is also possible to read the Special Key(s) on page 75.

DEFINE FIELD 3 BY: EITHER field separator

ÌHG0`Î a)

Read the field separator character from the HEX table. Range of characters = 00-FE. discard separator include separator

Ì01Î

Ì12Î OR match character b)

ÌHG3iÎ

Read the match character from the HEX table. Range of characters = 00-FE. OR field length c)

ÌHG1cÎ

Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length)

d)

ÌHG2fÎ AND Field 3 Terminators no field terminators

ÌHH0bÎ 121

Page 130

Exit and Save Configuration

ADVANCED FORMATTING

Ì$-?Î

1 field terminator

2 field terminators

ÌHH1eÎ

ÌHH2hÎ

Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 00-FE. For Wedge and USB-KBD interface, it is also possible to read the Special Key(s) on page 75.

DEFINE FIELD 4 BY: EITHER field separator

ÌHG0`Î a)

Read the field separator character from the HEX table. Range of characters = 00-FE. discard separator include separator

Ì01Î

Ì12Î OR match character b)

ÌHG3iÎ

Read the match character from the HEX table. Range of characters = 00-FE. OR field length c)

ÌHG1cÎ

Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length)

d)

ÌHG2fÎ AND Field 4 Terminators

122

Page 131

Exit and Save Configuration

ADVANCED FORMATTING

Ì$-?Î no field terminators

ÌHH0bÎ 1 field terminator

2 field terminators

ÌHH1eÎ

ÌHH2hÎ

Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 00-FE. For Wedge and USB-KBD interface, it is also possible to read the Special Key(s) on page 75.

DEFINE FIELD 5 BY: EITHER field separator

ÌHG0`Î a)

Read the field separator character from the HEX table. Range of characters = 00-FE. discard separator include separator

Ì01Î

Ì12Î OR match character b)

ÌHG3iÎ

Read the match character from the HEX table. Range of characters = 00-FE. OR field length c)

ÌHG1cÎ

Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length)

d)

ÌHG2fÎ AND

123