Page 122
Exit and Save Configuration
ADVANCED FORMATTING
Ì$-?Î
Define the timeout, which determines the valid waiting period between the two codes, in order to accept concatenation. If the timeout expires, the resulting action will be based on the following selection. (HHDII)
5
Transmission after Timeout no code transmitted after timeout
ÌEM0iÎ only code 1 transmitted (if read) after timeout
ÌEM1lÎ only code 2 transmitted (if read) after timeout
ÌEM2oÎ either code 1 or code 2 transmitted after timeout
ÌEM3rÎ
114
Page 123
ADVANCED FORMATTING
ADVANCED FORMATTING Advanced formatting has been designed to offer you complete flexibility in changing the format of barcode data before transmitting it to the host system. This formatting will be performed when the barcode data meets certain criteria, which you will define in the following procedure. Up to 4 advanced code management formats can be defined and saved in memory. For each format you must complete the entire configuration procedure: Read the Enter Configuration Command Step 1 Begin Format Definition 1, 2, 3, or 4 Steps 2 - 4 Define Match Code Conditions Step 5 Divide Code into Fields Step 6 Define Code Fields Steps 7 - 8 Add up to 2 Additional Fields Step 9 Define Field Transmission Step 10 Apply or Not Standard Message Formatting Step 11 End Format Definition 1, 2, 3, or 4 YES
Define another? NO
Enable Advanced Formats 1, 2, 3, 4 Define No Match Result Read the Exit and Save Configuration Command
115
Page 124
Enter Configuration
Ì$+;Î 1
Exit and Save Configuration
ADVANCED FORMATTING
Ì$-?Î
Begin Format Definition begin Format 1 definition
ÌHA0TÎ begin Format 2 definition
ÌHA1WÎ begin Format 3 definition
ÌHA2ZÎ begin Format 4 definition
ÌHA3]Î 2
Match Code Type match code type
ÌHB&Î Read the above code + the code type to match from the Code Identifier Table in Appendix B. OR any code type
ÌHB0VÎ 3
Match Code Length match code length
ÌHC(Î Read the above code + two numbers in the range 01 to 99 for the exact code length. OR any code length
ÌHC001Î 116
Page 125
Exit and Save Configuration
ADVANCED FORMATTING 4
Ì$-?Î
Match with Predefined Characters no match
ÌHD0HE00ÄÎ OR match with 1 character
ÌHD1]Î match with a 2-character string
ÌHD2`Î match with a 3-character string
ÌHD3cÎ match with a 4-character string
ÌHD4fÎ After selecting the predefined match code, read the character(s) from the HEX table. Range of characters = 00-FE. Example: Match code with the 2-character predefined string = "@@". Match with a 2-character string
Read AND
+ 40 + 40 position of first character in predefined string
ÌHE,Î
117
Page 126
Exit and Save Configuration
ADVANCED FORMATTING
Ì$-?Î
Read the above code + two numbers in the range 01 to 99 representing the character position in the code where the first character of the predefined string must be found. Read 00 if the match string can be found in any character position. See par. 5.8.1 for details.
5
Divide Code into Fields divide code into fields
ÌHF.Î Read one number in the range 1 to 5 to divide the code into fields.
6
Define Code Fields define code fields
Each code field length can be set by either: a) defining a field separator character to be found in the code itself. In this case you can choose to discard the code separator character or include it as the last character of the field. OR BY b) defining a match character to be found consecutively repeated in the code itself. In this case the field ends with the first character that does not match. OR BY c) specifying a specific character length up to the maximum of 99 characters. OR BY d) selecting the last field as variable length (if any).
You must define the same number of fields as selected in step 5, including fields that will not be transmitted.
118
Page 127
Exit and Save Configuration
ADVANCED FORMATTING
Ì$-?Î
DEFINE FIELD 1 BY: EITHER field separator
ÌHG0`Î a)
Read the field separator character from the HEX table. Range of characters = 00-FE. discard separator include separator
Ì01Î
Ì12Î OR match character
ÌHG3iÎ b)
Read the match character from the HEX table. Range of characters = 00-FE. OR field length
ÌHG1cÎ c)
Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length)
ÌHG2fÎ d)
AND Field 1 Terminators no field terminators
ÌHH0bÎ 1 field terminator
2 field terminators
ÌHH1eÎ
ÌHH2hÎ
119
Page 128
Exit and Save Configuration
ADVANCED FORMATTING
Ì$-?Î
Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 00-FE. For Wedge and USB-KBD interface, it is also possible to read the Special Key(s) on page 75.
DEFINE FIELD 2 BY: EITHER field separator
ÌHG0`Î a)
Read the field separator character from the HEX table. Range of characters = 00-FE. discard separator include separator
Ì01Î
Ì12Î OR match character
ÌHG3iÎ b)
Read the match character from the HEX table. Range of characters = 00-FE. OR field length
ÌHG1cÎ c)
Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length)
ÌHG2fÎ d)
AND Field 2 Terminators no field terminators
ÌHH0bÎ 1 field terminator
120
2 field terminators
Page 129
Exit and Save Configuration
ADVANCED FORMATTING
ÌHH1eÎ
Ì$-?Î ÌHH2hÎ
Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 00-FE. For Wedge and USB-KBD interface, it is also possible to read the Special Key(s) on page 75.
DEFINE FIELD 3 BY: EITHER field separator
ÌHG0`Î a)
Read the field separator character from the HEX table. Range of characters = 00-FE. discard separator include separator
Ì01Î
Ì12Î OR match character b)
ÌHG3iÎ
Read the match character from the HEX table. Range of characters = 00-FE. OR field length c)
ÌHG1cÎ
Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length)
d)
ÌHG2fÎ AND Field 3 Terminators no field terminators
ÌHH0bÎ 121
Page 130
Exit and Save Configuration
ADVANCED FORMATTING
Ì$-?Î
1 field terminator
2 field terminators
ÌHH1eÎ
ÌHH2hÎ
Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 00-FE. For Wedge and USB-KBD interface, it is also possible to read the Special Key(s) on page 75.
DEFINE FIELD 4 BY: EITHER field separator
ÌHG0`Î a)
Read the field separator character from the HEX table. Range of characters = 00-FE. discard separator include separator
Ì01Î
Ì12Î OR match character b)
ÌHG3iÎ
Read the match character from the HEX table. Range of characters = 00-FE. OR field length c)
ÌHG1cÎ
Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length)
d)
ÌHG2fÎ AND Field 4 Terminators
122
Page 131
Exit and Save Configuration
ADVANCED FORMATTING
Ì$-?Î no field terminators
ÌHH0bÎ 1 field terminator
2 field terminators
ÌHH1eÎ
ÌHH2hÎ
Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 00-FE. For Wedge and USB-KBD interface, it is also possible to read the Special Key(s) on page 75.
DEFINE FIELD 5 BY: EITHER field separator
ÌHG0`Î a)
Read the field separator character from the HEX table. Range of characters = 00-FE. discard separator include separator
Ì01Î
Ì12Î OR match character b)
ÌHG3iÎ
Read the match character from the HEX table. Range of characters = 00-FE. OR field length c)
ÌHG1cÎ
Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length)
d)
ÌHG2fÎ AND
123