Page 51

INSTALLATION

3

3.2 MECHANICAL DIMENSIONS Matrix 400™ can be installed to operate in different positions. The twelve screw holes (M4 x 5) on the body of the reader are for mechanical fixture (Figure 41). The diagram below gives the overall dimensions of the reader and may be used for its installation.

109 [4.29]

123 [4.85]

125 [4.93]

30.2 [1.19]

Refer to par. 3.3 for various mounting solutions and correct positioning and par. 7.2 for FOV vs. Reading Distance considerations.

60 [2.38]

18 [0.71] 41.5 [1.63] mm [in]

86 [3.41]

Ø65 [Ø2.54]

Figure 41 - Overall Dimensions

41

Page 52

MATRIX 400™ REFERENCE MANUAL

3 61 [2.40] 50 [1.97]

34 [1.34] 34 [1.34]

12.5 [0.49]

12.5 12.5 12.5 12.5 [0.49] [0.49] [0.49] [0.49]

= =

=

72.5 [2.85]

4.3 [0.17]

4 [0.16]

83.5 [3.29]

= 12.5 [0.49]

4.3 [0.17]

7 [0.28]

=

M4 [0.16] N°7 mm [in]

=

50 [1.97]

8.5 ] [0.33

4.2 [0.17]

70 [2.76]

15° 15°

Ø4 [ Ø 0 .2 .17 ]

=

40 [1.57]

3 [0.12] =

41.5 [1.63]

26.5 [1.04]

4.2 [0.17]

[0 4.2 .1 7]

45°

45°

25 Ø8. 2] .3 [Ø0

Figure 42 - Mounting Bracket Overall Dimensions

42

Page 53

INSTALLATION

3

3.3 MOUNTING AND POSITIONING MATRIX 400™ Using the Matrix 400™ mounting brackets you can obtain rotation on the various axes of the reader as shown in the diagram below:

Pitch

Tilt

Figure 43 –Positioning with Mounting Bracket (Back)

Pitch

Skew

Figure 44 –Positioning with Mounting Bracket (Side)

Pitch Tilt

Figure 45 –Positioning with Mounting Bracket (Front)

43

Page 54

MATRIX 400™ REFERENCE MANUAL

3

Matrix 400™ is able to decode code labels at a variety of angles, however significant angular distortion may degrade reading performance. When mounting Matrix 400™, take into consideration these ideal label position angles: Pitch or Skew 10° to 20° and Tilt 0°. Note: Since Matrix 400™ is omni-directional on the code plane, the Pitch and Skew angles have the same significance with respect to the code plane. However in some advanced code reading applications performance can be improved by modifying the Skew angle. Follow the suggestions below for the best orientation: The Pitch and Skew angles are represented by the values P and S in Figure 46 and in Figure 47. Position the reader in order to avoid the direct reflection of the light emitted by the Matrix 400™ reader; it is advised to assure at least 10° for one of these angles. In some cases, such as low contrast or low illumination, it can be useful to use a Pitch or Skew angle = 0°. P

S Assure at least 10° Minimize

Figure 46 - Pitch angle

Figure 47 - Skew angle

The Tilt angle is represented by the value T in Figure 48. Matrix 400™ can read labels with any tilt angle.

T Minimize

Figure 48 - Tilt angle

See par. 7.2 for FOV vs. Reading Distance considerations.

44

Page 55

CBX ELECTRICAL CONNECTIONS

4

4 CBX ELECTRICAL CONNECTIONS All Matrix 400™ models can be connected to a CBX connection box through one of the available CAB-MSxx accessory cables. These accessory cables terminate in a 19-pin connector on the Matrix 400™ side and in a 25-pin male D-sub connector on the CBX side. We recommend making system connections through one of the CBX connection boxes since they offer the advantages of easy connection, easy device replacement and filtered reference signals.

If you require direct wiring to the reader the details of the connector pins and relative connections are indicated in Chaper 5. NOTE The table below gives the pinout of the CBX100/500 terminal block connectors. Use this pinout when the Matrix 400™ reader is connected by means of the CBX100/500:

Vdc GND Earth +V I1A I1B -V +V I2A I2B -V +V -V O1+ O1O2+ O2TX RX SGND REF ID+ IDShield

CBX100/500 Terminal Block Connectors Input Power Power Supply Input Voltage + Power Supply Input Voltage Protection Earth Ground Inputs Power Source – External Trigger External Trigger A (polarity insensitive) External Trigger B (polarity insensitive) Power Reference – External Trigger Power Source – Inputs Input 2 A (polarity insensitive) Input 2 B (polarity insensitive) Power Reference – Inputs Outputs Power Source - Outputs Power Reference - Outputs Output 1 + Output 1 Output 2 + Output 2 Auxiliary Interface Auxiliary Interface TX Auxiliary Interface RX Auxiliary Interface Reference ID-NET™ Network Reference ID-NET™ network + ID-NET™ network Network Cable Shield Main Interface RS485 RS232 Full-Duplex TX TX+ *RX+ RX RTS TX*RXCTS SGND SGND

RS485 Half-Duplex RTX+ RTXSGND

* Do not leave floating, see par. 4.2.2 for connection details.

45

Page 56

MATRIX 400™ REFERENCE MANUAL

4

NOTE

To avoid electromagnetic interference when the reader is connected to a CBX connection box, verify the jumper positions in the CBX as indicated in its Installation Manual.

4.1 POWER SUPPLY Power can be supplied to the reader through the CBX100/500 spring clamp terminal pins as shown in Figure 49: Power Supply VGND V+ in

Earth Ground

Figure 49 - Power Supply Connections

The power must be between 10 and 30 Vdc only. It is recommended to connect the device CHASSIS to earth ground (Earth) by setting the appropriate jumper in the CBX connection box. See the CBX Installation Manual for details.

4.2 MAIN SERIAL INTERFACE

CAUTION

Do not connect to the Main Interface spring clamp terminals if using Host Interface Modules (Fieldbus) with the CBX500.

The signals relative to the following serial interface types are available on the CBX spring clamp terminal blocks. The main serial interface type and its parameters (baud rate, data bits, etc.) can be defined by the user via VisiSet™ software. The RS485 half duplex is automatically set whenever MUX32 communication protocol is enabled. For more details refer to the "Communication" folder in the VisiSet™ Help On Line. Details regarding the connections and use of the interfaces are given in the next paragraphs.

46

Page 57

CBX ELECTRICAL CONNECTIONS

4.2.1

4

RS232 Interface

The RS232 interface can be used for Point-to-Point, Pass Through or Master/Slave connections. When it is connected to the host computer it allows both transmission of code data and reader configuration by VisiSet™. The following pins are used for RS232 interface connection: CBX100/500 TX RX RTS CTS SGND

Function Transmit Data Receive Data Request To Send Clear To Send Signal Ground

It is always advisable to use shielded cables. The overall maximum cable length must be less than 15 m (49.2 ft). USER INTERFACE SGND RXD

TXD CTS

READER

SGND TX

RTS

RX RTS

CTS

Figure 50 – RS232 Main Interface Connections Using Hardware Handshaking

The RTS and CTS signals control data transmission and synchronize the connected devices.

+V RTS -V

START OF TRANSMISSION

END OF TRANSMISSION

DATA TRANSMISSION

+V TX DATA -V

DATA TRANSMISSION

C1 C2

C3

C4

C5

TRANSMISSION STOPPED ENABLED

+V CTS -V IDLE

ENABLED

DISABLED

IDLE

Figure 51 - RS232 Control Signals

If the RTS/CTS handshaking protocol is enabled, the Matrix 400™ activates the RTS output to indicate a message is to be transmitted. The receiving unit activates the CTS input to enable the transmission.

47

Page 58

MATRIX 400™ REFERENCE MANUAL

4

4.2.2

RS485 Full-Duplex Interface

The RS485 full-duplex (5 wires + shield) interface is used for non-polled communication protocols in point-to-point connections over longer distances (max 1200 m / 3940 ft) than those acceptable for RS232 communications or in electrically noisy environments. The CBX pinout follows: CBX100/500 TX+ RX+ TXRXSGND

Function RS485 Transmit Data + RS485 Receive Data + RS485 Transmit Data RS485 Receive Data Signal Ground

USER INTERFACE RX485+ TX485+ SGND

READER

RX485-

SGND TX+

TX485-

RX+ TX-

RX-

Figure 52 - RS485 Full-duplex Connections

For applications that do not use RX485 signals, do not leave these lines floating but connect them to SGND as shown below. NOTE USER INTERFACE RX485+ SGND

READER

RX485-

SGND TX+ TX-

Figure 53 - RS485 Full-duplex Connections using Only TX Signals

48

Page 59

CBX ELECTRICAL CONNECTIONS

4.2.3

4

RS485 Half-Duplex Interface This interface is provided for backward compatibility. We recommend using the more efficient ID-NET™ network for Master/Slave or Multiplexer layouts.

NOTE The RS485 half-duplex (3 wires + shield) interface is used for polled communication protocols. It can be used for Multidrop connections with a Datalogic Multiplexer, (see par. 6.5) exploiting a proprietary protocol based on polled mode called MUX32 protocol, where a master device polls slave devices to collect data. CBX100/500 RTX+ RTXSGND

Function RS485 Receive/Transmit Data + RS485 Receive/Transmit Data Signal Ground USER INTERFACE RTX485+ SGND

READER

RTX485-

SGND RTX+ RTX-

Figure 54 - RS485 Half-duplex Connections

This interface is forced by software when the protocol selected is MUX32 protocol. In a Multiplexer layout, the Multidrop address must also be set via serial channel by the VisiSet™ utility or by the Host Programming Mode. Figure 55 shows a multidrop configuration with Matrix 400™ readers connected to a Multiplexer.

CAUTION

This is an example of multidrop wiring. Consult the multiplexer manual for complete wiring instructions.

49

Page 60

MATRIX 400™ REFERENCE MANUAL

4

*

*

Figure 55 - Matrix 400™ Multidrop Connection to a Multiplexer * When using CBX500, the Main interface multidrop network signals: Shield, SGND, RTX+and RTX- are repeated on terminal connector row 4 to facilitate system cabling.

50