Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 14 of 15

Matrix 400 Reference Manual, pages 131 to 140

Pages 131 to 140 of 147

The original document is the PDF (15 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic Matrix-400

Page 131

SOFTWARE CONFIGURATION

8.4.4

8

Multi Image Acquisition Settings

When controlled variable conditions occur in the application, Multiple Image Acquisition Settings (up to 10), can be defined to create a database of parameter groups that handle each specific application condition. This database of pre-defined settings functions cyclically and therefore automatically improves system flexibility and readiness. For example, an application may have two stable but different lighting conditions which require different lighting options. One Image Acquisition Setting could enable and use an internal illuminator and a second setting could enable and use an external lighting system. These two groups will be used cyclically on each acquisition in order to automatically capture the correctly lighted image. Image Acquisition Settings are found in the VisiSet™ Calibration parameter setup menu. By selecting a different number and enabling its Status you can define the parameters for a new group.

8.4.5

Run Time Self Tuning (RTST)

Run Time Self-Tuning (RTST) increases Matrix’s flexibility in the presence of uncontrolled variable conditions (lighting, code contrast, etc.) by automatically adjusting its acquisition parameters. Self Tuning Calibration In the Calibration parameter setup menu, the Self Tuning parameters manage the Image Acquisition Setting parameters dynamically. Self Tuning provides automatic adjustment in run time of different acquisition parameters (Exposure Time and/or Gain) for each captured image based on calculations performed on previous acquisitions. These dynamic settings will be used instead of the static settings saved in memory.

From Not Readable to Readable

For more details see the Matrix 400™ Help On-Line. Self Tuning Image Processing In the Image Processing parameter setup menu, the Self Tuning parameters manage the Image Processing and Symbology related parameters. They perform different processing attempts on the same captured image according to the selected Self Tuning Mode parameter value: (Symbologies Only, Processing Modes Only, Decoding Methods Only, Code Contrast Levels Only, Image Mirroring Only, or General Purpose). For more details see the Matrix 400™ Help On-Line. 121

Page 132

MATRIX 400™ REFERENCE MANUAL

8

8.4.6

Region Of Interest Windowing

In order to satisfy very high throughput applications, higher frame rates can be achieved using the powerful Region Of Interest Windowing parameters in the Calibration parameter setup menu. Region Of Interest Windowing allows defining a region or window within the reader FOV. The Top, Bottom, Left and Right parameters allow to precisely define the image window to be processed, visualized and saved. In Matrix 400™ 600-0x0 models the frame rate is dependent on the number of lines (or rows) in the defined window. In Matrix 400™ 400-0x0 models the frame rate is dependent on the number of rows and columns in the defined window. The smaller the window, the lower the frame period and consequently the higher the frame rate. In general the Image Processing time can be reduced by reducing the window dimensions.

122

Page 133

SOFTWARE CONFIGURATION

8.4.7

8

Direct Part Marking Applications

Decoding Method: Direct Marking For DataMatrix and QR code the Decoding Method parameter selects the decoding algorithm according to the printing/marking technique used to create the symbol and on the overall printing/marking quality. The Direct Marking selection improves the decode rate for low quality Direct Part Mark codes and in general for Direct Part Mark codes with dot peening type module shapes.

Washed out and Axial Distortion

Dot Peening On Scratched Surface

Low Contrast Problem

Background Problems

Marked On Curved Shiny Surface

Axial distortion

Half moon effects

Shiny surface, noisy background

Low contrast, noisy background

All the previous examples are successfully read selecting the Direct Marking Decoding Method.

123

Page 134

MATRIX 400™ REFERENCE MANUAL

8 Image Filter

Sets the filter to be applied to the image before being processed. This parameter can be used to successfully decode particular ink-spread printed codes (ex. direct part mark codes). A different filter can be applied to each Image Acquisition Setting. The Erode Filter enlarges the image dark zones to increase readability.

Before - No Read

After - Readable Erode

The Dilate Filter enlarges the image white zones to increase readability.

Before - No Read

After - Readable Dilate

The Close filter eliminates dark areas (defects) in the white zones of the image. The Open filter eliminates white areas (defects) in the dark zones of the image.

124

Page 135

SOFTWARE CONFIGURATION

8

8.5 IMAGE CAPTURE AND DECODING By using the Capture Image and Decode Last Image functions from the VisiSet™ Main menu, you can get information about the image decodable codes in terms of Symbology, encoded Data, Position and Orientation, Decode Time and Code Quality Assessment Metrics.

Figure 128 - Capture and Decoding Functions

8.6 STATISTICS Statistics on the reading performance can be viewed by enabling the Statistics parameter and selecting the View Statistics item in the File menu. One of three different windows appears depending on the operating mode. Refer to the VisiSet™ Help On Line for more details.

Figure 129 - Code Statistics

125

Page 136

9

MATRIX 400™ REFERENCE MANUAL

9 MAINTENANCE 9.1 CLEANING Clean the reading window (see Figure A, 1) periodically for continued correct operation of the reader. Dust, dirt, etc. on the window may alter the reading performance. Repeat the operation frequently in particularly dirty environments. Use soft material and alcohol to clean the window and avoid any abrasive substances.

126

Page 137

TROUBLESHOOTING

10

10 TROUBLESHOOTING 10.1 GENERAL GUIDELINES When wiring the device, pay careful attention to the signal name (acronym) on the

CBX100/500 spring clamp connectors (chp. 4). If you are connecting directly to the Matrix 400™ M16 19-pin connector pay attention to the pin number of the signals (chp. 5). If you need information about a certain reader parameter you can refer to the VisiSet program help files. Either connect the device and select the parameter you’re interested in by pressing the F1 key, or select Help>Paramters Help from the command menu. If you’re unable to fix the problem and you’re going to contact your local Datalogic office or

Datalogic Partner or ARC, we suggest providing (if possible): Application Program version, Parameter Configuration file, Serial Number and Order Number of your reader. You can get this information while VisiSet™ is connected to the reader: the Application Program version is shown in the Terminal Window; the Parameter Configuration can be saved to an .ini file applying the File>Save Configuration File command in the Parameter Setup window; Serial Number and Order Number can be obtained by applying the respective command in the Tools menu. TROUBLESHOOTING GUIDE Problem

Suggestion

Power ON: the “POWER” LED is not lit.

Is power connected? If using a power adapter (like PG6000), is it connected to wall outlet? If using rail power, does rail have power? If using CBX, does it have power (check switch and

LED)? Check if you are referring to the M16 19-pin connector

One Shot or Phase Mode using the Input 1 (External Trigger) or Input 2: the ”TRIGGER” LED is not blinking while the External Trigger is switching.

or to the CBX spring clamp connectors. Measure Voltage either at pin A and pin L (for 19-pin connector) or at spring clamp Vdc and GND (for CBX). Check if you are referring to the 19-pin connector or to the CBX spring clamp connectors. Is the sensor connected to the Input 1 or Input 2? Is power supplied to the photo sensor? For NPN configuration, is power supplied to one of the two I1 or I2 signals (A or B)? For PNP configuration, is one of the two I1 or I2 signals grounded (A or B)? Are the photo sensor LEDS (if any) working correctly? Is the sensor/reflector system aligned (if present)? In the Digital I/O folder check the EXTERNAL TRIGGER or INPUT 2\Debounce Filter parameter setting. In the Operating Mode folder check the settings for Reading Phase-ON, Acquisition Trigger and Reading Phase-OFF parameters.

127

Page 138

MATRIX 400™ REFERENCE MANUAL

10

TROUBLESHOOTING GUIDE Problem

Suggestion

One Shot or Phase Mode In the Operating Mode folder check the settings for Reading Phase-ON, Acquisition Trigger and using serial trigger source: the ”TRIGGER” LED is not Reading Phase-OFF parameters. blinking. Are the COM port parameters (Baud Rate, Parity, Data Bits, Stop Bits, Handshake) correctly assigned? In the communication folder, check the settings of Reading Phase-ON String, Acquisition Trigger String and Reading Phase-OFF String parameters. Is the serial trigger source correctly connected? Is the Phase frequency lower than the maximum frame Phase Mode: the ”TRIGGER" LED is rate? correctly blinking but no image is displayed in VisiSet™ Calibration Tool window. Verify the correct software configuration settings. Continuous Mode: the ”TRIGGER” LED is not blinking. In the Data Collection folder check the settings for the Any Operating Mode: the ”TRIGGER” LED is CODE COLLECTION, DATA FORMAT and correctly blinking but no result STATISTICS parameter groups. is transmitted by the reader at the end of the reading phase collection. verify the Focus procedure Image not clear: Image focused but not verify the Calibrate Image Density prodcedure. decoded: Reading: Run the Rapid Configuration procedure in chapter 1. the reader always transmits Position the reader as described in par. 3.3 and through the No Read Message the VisiSet™ Calibration Tool: Tune the ACQUISITION TRIGGER DELAY, if the moving code is out of the reader field of view; Set the Continuous Operating Mode if no external trigger source is available; Tune the IMAGE ACQUISITION SETTING to improve the code image quality; Check the parameter setting in Decoding, 2D Codes, 1D Codes, and Postal Codes folders; View the full resolution code image to check the printing or marking quality. Communication: Is the serial cable wiring correct? reader is not transmitting If using CBX, be sure the RS485 termination switch is anything to the host. OFF. Are the host serial port settings the same as the reader serial port settings? In VisiSet™ Digital I/O folder, "COM" LED can be configured to indicate MAIN COM port TX or MAIN COM port RX.

128

Page 139

TROUBLESHOOTING

10 TROUBLESHOOTING GUIDE

Problem

Suggestion

Are the host serial port settings the same as the reader Communication: data transferred to the host serial port settings? are incorrect, corrupted or In VisiSet Communication folder check the settings of incomplete. Header and Terminator String parameters. In VisiSet™ Data Collection folder, check the settings of DATA FORMAT parameter group. How do I obtain my reader The reader Serial Number consists of 9 characters: one letter, 2 numbers, another letter followed by 5 numbers. Serial Number? The reader Serial Number is printed on a label that is affixed on the bottom case near the reading window. The Serial Number can also be obtained by selecting Tools/Get Reader Serial Number from the command menu in VisiSet. A dedicated window will appear. How do I obtain my reader The reader Order Number consists of 9 numbers. The reader Order Number can be obtained by selecting Order Number? the Tools/Get Reader Order Number from the command menu in VisiSet. A dedicated window will appear.

129

Page 140

MATRIX 400™ REFERENCE MANUAL

11

11 TECHNICAL FEATURES ELECTRICAL FEATURES Power Supply Voltage Power Consumption Communication Interfaces Main - RS232 - RS485 full-duplex - RS485 half-duplex Auxiliary - RS232 ID-NET™ Ethernet (Ethernet Models only) Inputs Input 1 (External Trigger) and Input 2 Max. Voltage Max. Input Current Outputs Output 1 and Output 2 VOut (ILoad = 0 mA) Max. VOut (ILoad = 10 mA) Max.

10 to 30 Vdc 0.8 to 0.27 A, 8 W max.; 0.5 to 0.17 A, 5 W typical

2400 to 115200 bit/s 2400 to 115200 bit/s 2400 to 115200 bit/s 2400 to 115200 bit/s Up to 1MBaud 10/100 Mbit/s Opto-coupled and polarity insensitive 30 Vdc 10 mA Opto-coupled 30 Vdc 1.8 Vdc

PD = VOut ILoad Max.

170 mW

OPTICAL FEATURES

4xx-xxx models

6xx-xxx models

Image Sensor Image Format Frame Rate Pitch

CMOS SXGA (1280x1024) 27 frames/sec.

CCD UXGA (1600x1200) 15 frames/sec.

Tilt

35° 0° - 360°

Lighting System LED Safety Class

Internal or External Illuminator (accessories) Class 1 to EN60825-1

ENVIRONMENTAL FEATURES Operating Temperature

0 to 50 C (32 to 122 °F) (high ambient temperature applications should use metal mounting bracket for heat dissipation)

Storage Temperature Max. Humidity Vibration Resistance EN 60068-2-6

-20 to 70 C (-4 to 158 °F) 90% non condensing 14 mm @ 2 to 10 Hz; 1.5 mm @ 13 to 55 Hz; 2 g @ 70 to 200 Hz; 2 hours on each axis

Bump Resistance EN 60068-2-29

30g; 6 ms; 5000 shocks on each axis

Shock Resistance EN 60068-2-27

30g; 11 ms; 3 shocks on each axis

Protection Class EN 60529

IP67 *

PHYSICAL FEATURES Dimensions Weight Material

125 x 65 x 86 mm (4.92 x 2.56 x 3.39 in.) with lens cover 482 g. (17 oz.) with lens and internal illuminator Aluminium

* when correctly connected to IP67 cables with seals and the Lens Cover is correctly mounted.

130