Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 13 of 15

Matrix 400 Reference Manual, pages 121 to 130

Pages 121 to 130 of 147

The original document is the PDF (15 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic Matrix-400

Page 121

SOFTWARE CONFIGURATION

8

8.4 CONFIGURATION Once connected to Matrix 400™ as described in par. 8.3, you can modify the configuration parameters as follows: 1. Press the Calibration Tool button from the Main Menu. Matrix 400™ will download its permanent memory configuration parameters with the default values (if it is the first time) to VisiSet™. The Calibration Tool window will be displayed together with the Parameter Setup window working in Interactive Mode (see par. 8.4.1 and par. 8.4.3). 2. Edit the Matrix 400™ configuration parameters according to your application requirements. 3. Use the Calibration Tool to fine tune the reading performance. See par. 8.4.3. 4. Close the Calibration Tool window and disable the Interactive Mode by pressing the interactive button. 5. Save the new configuration to the reader permanent memory by pressing the Send button. 6. Close the Parameter Setup window and press Disconnect on the VisiSet™ menu bar (see Figure 118) or launch Run Mode from the VisiSet™ Main menu. Disconnect exits closing communication between Matrix 400™ and VisiSet™, and causes Matrix 400™ to enter Run Mode. The disconnected reader serial port is now available. Run command does not close communication between Matrix 400™ and VisiSet™, and causes Matrix 400™ to enter Run Mode. In this case the reader output messages are displayed on the VisiSet™ terminal and the statistics are displayed in the Statistics window (Statistics enabled).

111

Page 122

MATRIX 400™ REFERENCE MANUAL

8

8.4.1

Edit Reader Parameters

The Parameter Setup window displays the configuration parameters grouped in a series of folders. Each parameter can be modified by selecting a different item from the prescribed list in the box, or by typing new values directly into the parameter box. By right clicking the mouse when positioned over the name of a specific Parameter or Group, a pop-up menu appears allowing you to directly manage that particular parameter or group. You can View the Selected Value for each parameter. You can Restore the Default Value of each parameter or of all the parameters of a group. Get Properties gives information about the parameter in the form of a pop-up hint that describes the default value and the range/list of valid values. The Short Help gives information about the parameter in the form of a pop-up hint.

Parameter Group

Parameter Single group/parameter management (right click)

Figure 123 - Editing Parameters

112

Page 123

SOFTWARE CONFIGURATION

8

Parameters to verify/modify: Operating Mode

Sets the parameters which customize the reader operating mode starting from three main modes: One Shot: acquires a single image based on the selected value for the Acquisition Trigger and Acquisition Trigger Delay. Continuous: continuously acquires images with a rate up to the maximum allowable frame rate per second for the given sensor depending on the decoding time and the Region of Interest settings. Phase Mode: acquires images during the reading phase depending on the selected value for the Acquisition Trigger and Acquisition Trigger Delay. The Reading Phase-ON and Reading Phase-OFF events mark respectively the beginning and end of the reading phase.

Calibration

Calibrates the acquisition parameters to maximize the reading performance (see par. 8.4.3).

Communication

Configures the parameters relative to each serial port regarding the transmission, message formatting and string receiving. Any change to the VisiSet™ communication port parameters (baud rate, data bits, etc.) is effective as soon as the reader is disconnected from VisiSet™.

Ethernet

Sets the parameters related to the Ethernet interface and to its communication channels.

CBX Gateway

Sets the parameters related to the External Host Interface Module through the CBX500 and to its communication channels.

Display

Sets the Display language and Layout of the BM150 Display when using the CBX500 connection box.

Diagnostics

Enables various diagnostic messages, formatting and actions.

Reading System Layout

Allows configuring the device according to the desired layout: Standalone, ID-NET™ or Master/Slave RS232

Image Processing

Sets the image processing parameters shared by all available symbologies.

1D & 2D, Postal Codes

Sets the characteristics of the code symbologies to be read.

Data Collection

Defines the code-collection parameters and the output message format.

Digital I/O

Configures the reader input/output parameters.

Match Code

Allows setting a user-defined code and relative parameters to which the read code will be compared (matched).

Miscellaneous

Sets the reader name and the saved image format.

Symbol Verification

Sets the parameters relative to the various specifications in the Standards which regulate code validation.

LEDs And Keypad

Sets the X-PRESS™ LED and Keypad parameters related to their selected Functions: Beeper, Green Spot, Setup, Positioning, etc.

113

Page 124

MATRIX 400™ REFERENCE MANUAL

8

When all the configuration parameters are set correctly, save them to the Matrix 400™ reader by pressing the Send button. See Figure 123. For successive configuration of other readers or for backup/archive copies, it is possible to save the configuration onto your PC by selecting the Save Configuration File option from the File menu. From the File menu, you can also Save Configuration As Text File for a human readable version. Load Configuration File (available in the File menu) allows you to configure a reader from a previously saved configuration file (.ini).

8.4.2

Send Configuration Options

The device parameters are divided into two main classes, Configuration and Environmental which are effected differently by the Send Configuration and Send Default Configuration commands. Configuration Parameters regard parameters that are specific to the device. These parameters are influenced by the Send Configuration and Send Default Configuration commands, that is they are overwritten by these commands. The same parameters are modified by the following "Send Configuration with Options" and "Send Default Configuration with Options" dialogs from the Device Menu:

114

Page 125

SOFTWARE CONFIGURATION

8

Environmental Parameters regard the device Identity and Position in a Network (ID-NET™, Master/Slave RS232, MUX 32, Ethernet) and are not influenced by the "Send Default Configuration" and "Send Configuration" commands. This allows individual devices to be configured differently without affecting their recognized position in the network. The following is a list of the Environmental Parameters: READING SYSTEM LAYOUT - Device Network Setting - Number of Slaves DEVICE NETWORK SETTINGS - Topology Role - ID-NET Slave Address - Network Baud Rate EXPECTED SLAVE DEVICES - Status - Device Description - Device Network Name MAIN PORT - Communication Protocol - Multidrop Address ETHERNET SYSTEM - Status - DHCP Client - IP Address - Subnet Mask - Gateway Address - DNS1 Address - DNS2 Address MISCELLANEOUS - Reader Name - User Name - Line Name - Lens Type & S/N - Internal Lighting System & S/N - Diaphragm Aperture - Focus Distance (mm)

115

Page 126

8

MATRIX 400™ REFERENCE MANUAL

For device replacement it is necessary to send the previously saved configuration (both Configuration and Environmental parameters) to the new device. To do this select "Send Configuration with Options" from the Device Menu and check the Environmental Parameters checkbox:

In order to return a device to its absolute default parameters including Environmental parameters, the following Send Default Configuration with Options" dialog must be used:

116

Page 127

SOFTWARE CONFIGURATION

8.4.3

8

Calibration

VisiSet™ provides a Calibration Tool to maximize the reading performance by tuning the acquisition parameters and the time of the delayed triggers. By selecting the Calibration Tool from the VisiSet™ Main Menu (F), the following window appears together with the Parameter Setup window:

Figure 124 - Calibration OK

This tool provides a "real-time" image display while Matrix 400™ is reading. It also gives immediate results on the performance of the installed Matrix 400™ reader. The Parameter Setup window works in Interactive Mode in order to cause each parameter setting to be immediately effective.

NOTE

If you want to save the temporary configuration to permanent memory, you must first close the Calibration Tool window. Then, you must disable the Interactive Mode and select the Permanent Memory option from the Send Configuration item in the Device menu.

117

Page 128

MATRIX 400™ REFERENCE MANUAL

8

The following examples show some of the typical conditions occurring during the installation: Under-exposure: To correct this result it is recommended to change the following parameters in their order of appearance: 1. increase the Exposure Time 2. increase the Gain In general, a longer exposure time corresponds to a lighter image but is susceptible to blurring due to code movement. Exposure time is also limited by the Internal Lighting mode parameter. Longer esposure times can be set if the power strobe level is lowered. NOTE

High gain settings may produce a grainy image that may affect the decoding process.

Figure 125 - Example Under Exposure: Too Dark

118

Page 129

SOFTWARE CONFIGURATION

8

Over-exposure: To correct this result it is recommended to change the following parameters in their order of appearance: 1. decrease the Gain 2. decrease the Exposure Time

Figure 126 - Example Over Exposure: Too Light

119

Page 130

MATRIX 400™ REFERENCE MANUAL

8 Moving code out of the Field of View:

To correct this result and have the code completely visible in F.O.V., it is possible to follow one or both the procedures listed below: reposition the reader use the Acquisition Trigger Delay by tuning the Delay Time (x100µs)

Figure 127 - Example out of FOV

120