The text of a manual · part 1 of 15
Matrix 400 Reference Manual, pages 1 to 10
Pages 1 to 10 of 147
The original document is the PDF (15 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic Matrix-400
Page 1
w DATALOGIC.
MATRIX 400™
Reference Manual
Page 2
Datalogic Automation S.r.l. Via Lavino, 256 40050 - Monte S. Pietro Bologna - Italy
Matrix 400™ Reference Manual Ed.: 06/2010
© 2007 – 2010 Datalogic Automation S.r.l. ALL RIGHTS RESERVED. Protected to the fullest extent under U.S. and international laws. Copying, or altering of this document is prohibited without express written consent from Datalogic Automation S.r.l. Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. Matrix 400, ID-NET, VisiSet and X-PRESS are trademarks of Datalogic Automation S.r.l. All other brand and product names mentioned herein are for identification purposes only and may be trademarks or registered trademarks of their respective owners. Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or consequential damages resulting from the use of this material.
18/06/10
Page 3
CONTENTS REFERENCES ............................................................................................................vi Conventions................................................................................................................. vi Reference Documentation ........................................................................................... vi Service and Support .................................................................................................... vi Patents......................................................................................................................... vi COMPLIANCE............................................................................................................vii EMC Compliance.........................................................................................................vii Power Supply...............................................................................................................vii LED Class....................................................................................................................vii CE Compliance............................................................................................................vii FCC Compliance .........................................................................................................vii HANDLING................................................................................................................viii GENERAL VIEW ..........................................................................................................x 1
RAPID CONFIGURATION ...........................................................................................1 Step 1 – Assemble the Reader..................................................................................... 1 Step 2 – Connect the System .......................................................................................2 Step 3 – Mount and Position the Reader......................................................................5 Step 4 – Focus the Reader........................................................................................... 6 Step 5 – Calibrate Image Density ................................................................................. 7 Step 6 – X-PRESS™ Configuration..............................................................................9 Step 7 – Installing VisiSet™ Configuration Program .................................................. 11 Step 8 – Configuration Using Setup Wizard ............................................................... 12 Step 9 – Test Mode ....................................................................................................18 Advanced Reader Configuration................................................................................. 19
2 2.1 2.2 2.3 2.3.1 2.3.2 2.4 2.4.1 2.5 2.6 2.7 2.8
INTRODUCTION ........................................................................................................20 Product Description .................................................................................................... 20 Indicators and Keypad Button..................................................................................... 24 ID-NET™ ....................................................................................................................25 How To Setup/Configure the Reader Network ........................................................... 26 ID-NET™ Slave Management Through Master.......................................................... 28 X-PRESS™ Human Machine Interface ...................................................................... 29 X-PRESS™ Functions................................................................................................29 Model Description .......................................................................................................31 Accessories ................................................................................................................32 Application Examples .................................................................................................33 External Lighting Systems ..........................................................................................36
3 3.1 3.2 3.3
INSTALLATION .........................................................................................................40 Package Contents ......................................................................................................40 Mechanical Dimensions.............................................................................................. 41 Mounting and Positioning Matrix 400™ ...................................................................... 43
4 4.1 4.2 4.2.1 4.2.2
CBX ELECTRICAL CONNECTIONS.........................................................................45 Power Supply..............................................................................................................46 Main Serial Interface...................................................................................................46 RS232 Interface..........................................................................................................47 RS485 Full-Duplex Interface.......................................................................................48 iii
Page 4
4.2.3 4.3 4.3.1 4.3.2 4.3.3 4.4 4.5 4.6 4.7 4.8
RS485 Half-Duplex Interface ...................................................................................... 49 ID-NET™ Interface .....................................................................................................51 ID-NET™ Cables ........................................................................................................51 ID-NET™ Response Time .......................................................................................... 52 ID-NET™ Network Termination .................................................................................. 56 Auxiliary RS232 Interface ...........................................................................................56 Inputs .......................................................................................................................... 57 Outputs .......................................................................................................................60 External Lighting Systems ..........................................................................................62 User Interface - Host...................................................................................................63
5 5.1 5.2 5.3 5.4 5.4.1 5.4.2 5.4.3 5.5 5.5.1 5.5.2 5.5.3 5.6 5.7 5.8 5.9 5.10
MATRIX 400™ CONNECTOR ELECTRICAL CONNECTIONS ................................ 64 M16 19-Pin Connector................................................................................................64 M12-D 4-Pin Connector (Ethernet) ............................................................................. 65 Power Supply..............................................................................................................65 Main Serial Interface...................................................................................................65 RS232 Interface..........................................................................................................66 RS485 Full-Duplex Interface.......................................................................................67 RS485 Half-Duplex Interface ...................................................................................... 68 ID-NET™ Interface .....................................................................................................70 ID-NET™ Cables ........................................................................................................70 ID-NET™ Response Time .......................................................................................... 71 ID-NET™ Network Termination .................................................................................. 75 Auxiliary RS232 Interface ...........................................................................................75 Ethernet Interface (Matrix 400 XXX-010 models only) ............................................... 76 Inputs .......................................................................................................................... 77 Outputs .......................................................................................................................80 User Interface .............................................................................................................82
6 6.1 6.2 6.2.1 6.2.2 6.3 6.4 6.5 6.6
TYPICAL LAYOUTS ..................................................................................................83 Point-to-Point ..............................................................................................................83 Pass-Through .............................................................................................................86 Pass-Through on RS232 ............................................................................................86 Pass-Through on ID-NET™........................................................................................ 87 ID-NET™ ....................................................................................................................88 RS232 Master/Slave................................................................................................... 94 Multiplexer ..................................................................................................................95 Ethernet Connection ...................................................................................................96
7 7.1 7.2 7.2.1 7.2.2 7.2.3 7.3
READING FEATURES...............................................................................................98 Optical Accessory Selection ....................................................................................... 98 Horizontal FOV vs. Reading Distance Diagrams........................................................ 99 How to Use the Diagrams...........................................................................................99 1D (Linear) Codes ....................................................................................................100 2D (Bi-dimensional) Codes....................................................................................... 102 Maximum Line Speed and Exposure Time Calculations .......................................... 104
8 8.1 8.2 8.3 8.3.1 8.4 8.4.1 8.4.2
SOFTWARE CONFIGURATION.............................................................................. 107 VisiSet™ System Requirements...............................................................................107 Installing VisiSet™....................................................................................................108 Startup ......................................................................................................................108 VisiSet™ Options......................................................................................................109 Configuration ............................................................................................................111 Edit Reader Parameters ........................................................................................... 112 Send Configuration Options...................................................................................... 114 iv
Page 5
8.4.3 8.4.4 8.4.5 8.4.6 8.4.7 8.5 8.6
Calibration.................................................................................................................117 Multi Image Acquisition Settings...............................................................................121 Run Time Self Tuning (RTST) ..................................................................................121 Region Of Interest Windowing .................................................................................. 122 Direct Part Marking Applications............................................................................... 123 Image Capture and Decoding................................................................................... 125 Statistics ...................................................................................................................125
9 9.1
MAINTENANCE .......................................................................................................126 Cleaning....................................................................................................................126
10 10.1
TROUBLESHOOTING .............................................................................................127 General Guidelines ...................................................................................................127
11
TECHNICAL FEATURES......................................................................................... 130 GLOSSARY..............................................................................................................132 INDEX.......................................................................................................................135 v
Page 6
REFERENCES CONVENTIONS This manual uses the following conventions: "User" refers to anyone using a Matrix 400™ reader. "Reader" refers to the Matrix 400™ reader. "You" refers to the System Administrator or Technical Support person using this manual to install, configure, operate, maintain or troubleshoot a Matrix 400™ reader.
REFERENCE DOCUMENTATION For further details refer to: the VisiSet™ Help On Line, Matrix Reading Methods, Matrix Host Mode Programming, Matrix SW Parameter Guide, Matrix Code Quality Verifier Solution provided as supplementary documentation on CD-ROM.
SERVICE AND SUPPORT Datalogic provides several services as well as technical support through its website. Log on to www.automation.datalogic.com and click on the links indicated for further information:
PRODUCTS Search through the links to arrive at your product page which describes specific Info, Features, Applications, Models, Accessories, and Downloads including the VisiSet™ utility program, which allows device configuration using a PC. It provides RS232 and Ethernet interface configuration.
SERVICE - Overview - Warranty Extensions and Maintenance Agreements - Sales Network- Listing of Subsidiaries, Repair Centers, Partners - Helpdesk - Material Return Authorization
PATENTS This product is covered by one or more of the following patents: U.S. patents: 6,512,218 B1; 6,616,039 B1; 6,808,114 B1; 6,997,385 B2; 7,102,116 B2; 7,282,688 B2 European patents: 999,514 B1; 1,014,292 B1; 1,128,315 B1. Additional patents pending.
vi
Page 7
COMPLIANCE For installation, use and maintenance it is not necessary to open the reader.
EMC COMPLIANCE In order to meet the EMC requirements: connect reader chassis to the plant earth ground by means of a flat copper braid shorter than 100 mm; for CBX connections, connect the pin "Earth" to a good Earth Ground for direct connections, connect the main interface cable shield to pin K of the 19-pin connector;
POWER SUPPLY ATTENTION: READ THIS INFORMATION BEFORE INSTALLING THE PRODUCT This product is intended to be installed by Qualified Personnel only. This product is intended to be connected to a UL Listed Computer which supplies power directly to the reader or a UL Listed Direct Plug-in Power Unit marked LPS or “Class 2”, rated 10 to 30 V, minimum 1 A.
LED CLASS Class 1 LED Product to EN60825-1:2001
CE COMPLIANCE Warning: This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment. This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference which may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
vii
Page 8
HANDLING The Matrix 400™ is designed to be used in an industrial environment and is built to withstand vibration and shock when correctly installed, however it is also a precision product and therefore before and during installation it must be handled correctly to avoid damage.
avoid that the readers are dropped (exceeding shock limits).
do not fine tune the positioning by striking the reader or bracket.
viii
Page 9
do not weld the reader into position which can cause electrostatic, heat or reading window damage.
do not spray paint near the reader which can cause reading window damage.
ix
Page 10
GENERAL VIEW Matrix 400™
1
3
2
4
5
2
7
10
2
8
9
6 Figure A
1
Device Class Label
6
HMI X-PRESS™ Interface
2
Mounting Holes (12)
7
"POWER ON" LED
3
Lens Cover
8
Power - Serial Interfaces - I/O Connector
4
Lens (separate accessory)
9
Ethernet Connector (Ethernet Models Only)
5
Internal Illuminator (separate accessory)
10 Ethernet Connection LED (Ethernet Models Only)
x